30G 1/2\ (13mm) Needle (Yellow) Unisharp x 100
Unisharp
Injection & InfusionHypodermic Needles (Luer slip)
Certifications
- CE Marked medical device (hypodermic needle).
- Colour coding compliant with EN ISO 6009 for 30G (yellow) needles.
- Medical Grade, latex Free, and PVC Free components as stated by some distributors.
- Manufactured under quality management systems audited for medical devices (e.g., ISO 9001) as reported for Exchange Supplies as a supplier.
- CE Marked medical device (hypodermic needle).
- Colour coding compliant with EN ISO 6009 for 30G (yellow) needles.
- Medical Grade, latex Free, and PVC Free components as stated by some distributors.
- Manufactured under quality management systems audited for medical devices (e.g., ISO 9001) as reported for Exchange Supplies as a supplier.
Hypodermic Needles (Luer slip)
Description
Yellow hypodermic needle: ultra-fine 30G, 13mm (0.5 inch) detachable needle for use with all standard Luer slip and Luer lock syringes. Individually blister packed, sterile, single-use needle designed primarily for subcutaneous injections and for intravenous injection into small or superficial veins.
Bnefits
- Ultra-fine 30G needle designed to minimise injection discomfort and tissue trauma.
- Short 13mm (0.5 inch) length suitable for subcutaneous and superficial intravenous injections.
- Compatible with all standard Luer slip and Luer lock syringes made for detachable needles.
- Individually blister packed and sterile to support infection prevention and single-patient use.
- Colour-coded yellow hub for easy gauge identification in line with EN ISO 6009.
- High-quality, good value needle widely used in medical, aesthetic, and harm-reduction settings.
Indications
- Subcutaneous injection of medications by trained healthcare professionals (e.g., vaccines, hormones, local anaesthetics, and aesthetic injectables).
- Intravenous injection into small or superficial veins where a fine-gauge, short needle is appropriate.
- General clinical use where a 30G, 13mm hypodermic needle is specified for human or veterinary applications.
- Use only by, or under the supervision of, appropriately trained healthcare professionals.
Composition
- Stainless steel hypodermic needle with silicone coating to reduce penetration force and friction.
- Transparent, yellow colour-coded plastic Luer slip hub (PVC-free, latex-free).
- Needle protective cap supplied on each needle.
- Sterile, single-use medical device.
Formulation
- Gauge/Size: 30G (ultra-fine).
- Needle length: 13mm (0.5 inch).
- Needle type: detachable hypodermic needle for Luer slip and Luer lock syringes.
- Hub colour: yellow (30G colour code).
- Bevel: sharp lancet point, thin-wall needle construction.
- Sterility: terminally sterilised, individually wrapped.
Packaging
- Box of 100 individually blister-packed needles.
- Each needle supplied with protective cap in sterile packaging.
- Outer carton labelled with gauge, length, colour code, batch/lot number, and expiry date.
Usage
- Check packaging is intact and within expiry date before use; do not use if blister is damaged or opened.
- Attach the needle securely to a compatible Luer slip or Luer lock syringe using aseptic technique.
- Prime the needle as required and perform the injection according to local clinical protocols and manufacturer instructions for the medicinal product.
- Do not bend the needle, do not re-cap after use unless local policy specifically permits and safe technique is used.
- Dispose of the used needle and syringe immediately after use into an approved sharps container; single use only.
Contraindications
- Do not use if the sterile blister or outer packaging is damaged, opened, or past the expiry date.
- Do not reuse, re-sterilise, or share needles between patients.
- Not suitable for intra-arterial, intrathecal, intraocular, or other specialised injection routes unless explicitly specified by local clinical guidelines.
- Do not use in patients with known hypersensitivity to any component of the device (e.g., stainless steel) without appropriate risk assessment.
- Use with caution, and only by trained professionals, in patients with fragile or compromised veins.
Adverse Effects
- Local injection-site reactions such as pain, erythema, bleeding, bruising, or minor haematoma.
- Rare risk of infection at the injection site if aseptic technique is not followed.
- Potential for needle-stick injury to the operator if sharps handling and disposal protocols are not followed.
- Very rare risk of needle breakage or vascular/nerve injury associated with injection procedures in general.
Storage Conditions
- Store in a clean, dry place at room temperature, away from direct sunlight and sources of heat.
- Keep in original packaging until point of use to maintain sterility and product identification.
- Protect from excessive moisture and mechanical damage (crushing, bending).
- Keep out of reach of children and unauthorised users.
Duration
Not applicable \u2013 this is a single-use hypodermic needle; treatment duration is determined by the medicinal product and clinical protocol.
Onset
Not applicable \u2013 onset of effect depends on the drug administered and route of administration, not on the needle itself.