Open Suction Catheter, Graduated, 8ch x 48cm, Two Side Eyes Box of 100
Pennine Healthcare Oppo-Cath
Injection & InfusionOpen Suction Catheter
Certifications
- CE Marked sterile single Use suction catheter as a medical device for airway management in accordance with applicable European medical device regulations.
- Manufactured under an ISO 13485:2016 Certified quality management system by Pennine Healthcare (Certificate MD 648425).
- Manufactured in ISO 14644 1 classified cleanroom environments as part of Pennine’s airway management product range.
- Designed and tested to meet relevant standards for sterile suction catheters used in respiratory tract procedures (e.g. ISO 8836 for suction catheters, as referenced in tender and technical documents).
- CE Marked sterile single Use suction catheter as a medical device for airway management in accordance with applicable European medical device regulations.
- Manufactured under an ISO 13485:2016 Certified quality management system by Pennine Healthcare (Certificate MD 648425).
- Manufactured in ISO 14644 1 classified cleanroom environments as part of Pennine’s airway management product range.
- Designed and tested to meet relevant standards for sterile suction catheters used in respiratory tract procedures (e.g. ISO 8836 for suction catheters, as referenced in tender and technical documents).
Open Suction Catheter
Description
The Open Suction Catheter, Graduated, 8ch x 48cm, Two Side Eyes - Box of 100 is a Pennine Healthcare Oppo-Cath suction catheter designed for oral, tracheal and endobronchial suction procedures. It is a sterile, single-use, medical grade PVC catheter with a clear Prestrol vacuum-control connector, 1 cm graduations along the 48 cm tube, a terminal distal opening and two small opposed side eyes (Oppo eyes) to reduce tissue trauma. The catheter is colour-coded for size identification (8ch, approx. 2.7 mm diameter) and supplied individually wrapped in peel pouches, with 100 catheters per box.
Bnefits
- Designed specifically for oral, tracheal and endobronchial suction procedures to maintain airway patency.
- Medical grade PVC construction provides flexibility, kink resistance and atraumatic insertion characteristics.
- Clear Prestrol vacuum-control connector allows fingertip suction control for safer, more controlled suctioning.
- Graduations every 1 cm along the 48 cm tube assist with accurate depth placement and documentation.
- Terminal distal eye with two small opposed side eyes (Oppo eyes) helps reduce mucosal trauma and improves suction efficiency.
- Colour-coded connector facilitates rapid identification of catheter size (8ch) in clinical settings.
- Sterile, single-use, individually peel-packed catheters support infection prevention and reduce cross-contamination risk.
- Compatible with standard suction tubing and suction sources commonly used in ward, theatre, ICU and emergency settings.
Indications
- Oral, tracheal and endobronchial suction procedures to remove respiratory secretions.
- Airway clearance in intubated or tracheostomised patients in intensive care, theatre, emergency or ward environments.
- Maintenance of airway patency in patients unable to clear their own secretions effectively.
- Use during anaesthesia and post-operative care to remove blood, mucus or other fluids from the airway.
- General respiratory suctioning where an 8ch (2.7 mm) catheter is clinically appropriate for patient size and airway device.
Composition
- Tube: medical grade PVC suction catheter, 48 cm length.
- Connector: clear Prestrol vacuum-control funnel connector with colour coding for size identification.
- Distal configuration: terminal distal eye plus two small opposed side eyes (Oppo eyes) at approximately 180° orientation.
- Size: 8ch (French), approximate outer diameter 2.7 mm.
Formulation
- Single-use sterile medical device – PVC suction catheter with Prestrol vacuum-control connector and two opposed side eyes, graduated every 1 cm along the tube.
Packaging
- Each catheter is supplied sterile in an individual peel pouch.
- Box of 100 catheters (inner box) with product code OSC-1208/48 and size/length clearly marked.
- Outer carton suitable for storage in clinical supply areas.
Usage
- Use only by trained healthcare professionals familiar with suctioning techniques and airway management.
- Select the appropriate catheter size (8ch) based on patient size, airway device and clinical requirements.
- Open the sterile peel pouch using aseptic technique and connect the Prestrol vacuum-control connector to compatible suction tubing and suction source.
- If required, pre-measure the insertion depth using the 1 cm graduations on the catheter to avoid advancing too deeply into the airway.
- Gently insert the catheter into the patient’s mouth, tracheal tube or tracheostomy tube without applying suction, advancing to the predetermined depth.
- Apply suction by occluding the vacuum-control port on the Prestrol connector with a gloved finger while slowly withdrawing or intermittently advancing and withdrawing the catheter, following local protocol.
- Limit suction time per pass (commonly 10–15 seconds or less) and allow the patient to rest and re-oxygenate between passes, in accordance with local guidelines.
- Monitor the patient’s oxygen saturation, heart rate and overall clinical status throughout the procedure.
- After use, disconnect the catheter and dispose of it immediately as clinical waste in accordance with local infection prevention and control policies; do not reuse.
- Do not use if the sterile packaging is opened, damaged or contaminated, or if the catheter shows signs of damage or manufacturing defect.
Contraindications
- Relative contraindication in patients with significant coagulopathy or thrombocytopenia due to increased risk of mucosal bleeding, unless clearly indicated and performed with caution.
- Use with caution in patients with raised intracranial pressure, unstable cardiovascular status or severe hypoxia, where suctioning may exacerbate clinical instability.
- Do not use where the required catheter size differs from 8ch; select an appropriate size based on patient and airway characteristics.
- Do not reuse; single-use device only. Reuse may increase risk of infection, loss of performance and patient harm.
- Do not use if catheter or packaging appears damaged, contaminated or past expiry date.
Adverse Effects
- Local mucosal irritation or trauma, including minor bleeding, due to mechanical contact with airway tissues.
- Transient coughing, gagging or discomfort during suction catheter insertion and suctioning.
- Potential for hypoxia, bronchospasm, arrhythmias or hemodynamic instability if suctioning is prolonged, too frequent or performed without adequate oxygenation and monitoring.
- Rare risk of airway damage if the catheter is inserted too forcefully or beyond safe depth.
- Infection risk if aseptic technique is not followed or if catheters are reused contrary to instructions.
Storage Conditions
- Store in a clean, dry environment away from direct sunlight and excessive heat or humidity.
- Keep in original packaging until point of use to maintain sterility and protect from physical damage.
- Observe any temperature and storage recommendations given on the manufacturer’s packaging (typically ambient room temperature).
- Do not use after the expiry date printed on the box or individual pouch.
- Avoid compressing or sharply bending boxes to prevent deformation of the catheters and packaging.
Duration
Used for short, intermittent suctioning episodes; each catheter is intended for a single suction procedure and should be discarded immediately after use.
Onset
Immediate removal of secretions during suctioning, with rapid improvement in airway clearance when the catheter is used correctly.
| Price | Link |
|---|---|
| £53.99 | https://www.medisave.co.uk/products/open-suction-catheter-graduated-10-x-48cm-two-side-eyes-box-of-100 |
| Price | Link |
|---|---|
| £53.99 | https://www.medisave.co.uk/products/open-suction-catheter-graduated-12-x-48cm-two-side-eyes-box-of-100 |