Easyflow Irrigation Set Double Lead with Bubble Trap
Baxter
Medical Device
Irrigation / Infusion Set
Certifications
CE Marked as a single Use medical irrigation / infusion set.
Manufactured to medical device standards and intended for hospital/surgical use as listed by distributor and manufacturer.
CE Marked as a single Use medical irrigation / infusion set.
Manufactured to medical device standards and intended for hospital/surgical use as listed by distributor and manufacturer.
Irrigation / Infusion Set
Description
The Easyflow Irrigation Set – Double Lead with Bubble Trap (code EMC4055N) is a sterile, single-use Y-type irrigation set designed for medical irrigation and infusion procedures. The set includes two Easyflow spikes with protectors, two clamps, a chamber with a bubble trapper to remove air bubbles from fluid lines, a 1676 mm tube (ID 7.05 mm), a roller clamp, a medical clamp, a catheter adapter with silicone tubing (114 mm long, ID 4.75 mm) and a cap. It is intended to safely deliver irrigation or infusion fluids while minimising the risk of air embolism, and is CE-marked. The set is supplied sterile and individually wrapped for single-patient use.
Bnefits
Dual-lead Y-type design allows simultaneous connection of two fluid sources or high-flow irrigation from a single bag.
Integrated bubble-trap chamber helps remove air bubbles, reducing risk of air embolism during infusion or irrigation.
Long tubing (≈1676 mm) provides flexibility and mobility for clinical setups.
Includes all necessary components (spikes, clamps, catheter adapter, silicone tubing) in a single sterile set — ready to use out of the pack.
Single-use, sterile and disposable — minimises cross-contamination and infection risk.
CE-marked medical device supplied by a recognised distributor.
Indications
Irrigation of body cavities, surgical sites or organs requiring sterile fluid flushing.
Continuous bladder or urinary tract irrigation (e.g. post-surgery or catheter maintenance) when used with appropriate catheter / drainage systems.
General infusion or irrigation procedures where controlled fluid delivery and air-bubble removal are required.
Endoscopic irrigation during urological or surgical procedures (when used with appropriate endoscope sheath and sterile fluid).
Composition
Flexible medical-grade tubing (PVC or equivalent) — main tube 1676 mm length with internal diameter 7.05 mm
Silicone tubing adapter — 114 mm long, internal diameter 4.75 mm
Injection spikes (2) with protective caps
Roller clamp and medical clamp (clamp components likely PVC or medical-grade polymer)
Y-type connector / bubble-trap chamber (moulded plastic / medical polymer)
Catheter adapter and cap (medical-grade plastic / polymer components)
Formulation
Disposable sterile irrigation/infusion set in Y-lead configuration
Single-use components pre-assembled and sterilised; ready for aseptic connection to fluid bags and catheters
Includes inline bubble trap chamber to capture air before fluid enters patient line
Packaging
Individually sterile-wrapped pouch for single-use irrigation set
Labelled with product code EMC4055N, CE mark and sterile status
Sold individually (each) or as multipack cartons depending on supplier (e.g. 15 units per case per distributor listing)
Usage
Use only once — the irrigation set is designed for single-use. Do not re-sterilise or reuse.
Maintain aseptic technique when opening packaging and connecting spikes to fluid bags.
Hang fluid bag(s) on IV stand, insert spike(s) into fluid bag port(s), and ensure protective caps are removed properly before use.
Open clamps and allow fluid to flow through the tubing until all air is expelled via the bubble-trap chamber, ensuring no air bubbles remain.
Connect catheter adapter or intended endoscope/instrument via the silicone tubing adapter.
Adjust flow rate using the roller clamp as needed for the procedure or irrigation requirements.
After use, discard the entire set (tubing, connectors, spikes, clamps) into appropriate medical sharps / biohazard waste container, following local disposal protocols.
Contraindications
Do not use if the sterile pouch packaging is damaged or opened prior to use — sterility cannot be guaranteed.
Not for long-term indwelling use — the set is designed for short-term irrigation/infusion only.
Do not reuse or re-sterilise — reuse may compromise integrity and sterility, increasing risk of infection or device failure.
Adverse Effects
Risk of infection if aseptic technique is not maintained or if set sterility is compromised.
Potential for air embolism if air is not properly expelled before connection due to user error.
Local reaction or irritation if incompatible fluid or medication is used.
Mechanical failure or leakage if tubing or connectors are damaged during handling — may result in fluid spillage or compromised irrigation.
Storage Conditions
Store unopened irrigation set in a clean, dry place at room temperature away from direct sunlight.
Keep in original sterile packaging until use to maintain sterility.
Do not freeze or expose to extreme temperatures.
Handle gently to avoid damaging tubing, spikes or connectors prior to use.