Edge Safety Needle Pink 18G x 38 mm (1 1/2\) x 1000
Needle-Pro EDGE
Injection & Infusion
Safety hypodermic needles
Certifications
CE Marked sterile, single Use safety hypodermic needle device (medical device, not a medicinal product).
Safety Engineered device designed to meet NIOSH/CDC recommendations for needlestick injury prevention.
Colour coding conforms to ISO standard colour identification for needle gauge sizes.
Manufactured under a certified medical device quality management system (e.g. ISO 13485) by ICU Medical / Smiths Medical.
Complies with applicable sharps safety regulations and occupational health guidelines in relevant markets.
CE Marked sterile, single Use safety hypodermic needle device (medical device, not a medicinal product).
Safety Engineered device designed to meet NIOSH/CDC recommendations for needlestick injury prevention.
Colour coding conforms to ISO standard colour identification for needle gauge sizes.
Manufactured under a certified medical device quality management system (e.g. ISO 13485) by ICU Medical / Smiths Medical.
Complies with applicable sharps safety regulations and occupational health guidelines in relevant markets.
Safety hypodermic needles
Description
The Edge Safety Needle Pink - 18G x 38 mm (1 1/2\) x 1000 is the Jelco Hypodermic Needle-Pro EDGE safety hypodermic needle from ICU Medical (formerly Smiths Medical). It is a sterile, single-use hypodermic needle with a hinged, manually activated safety sheath designed to help protect clinicians from needlestick injuries. The 18G, 38 mm (1.5 inch) stainless steel needle is colour-coded pink in accordance with ISO gauge standards. The integrated Needle-Pro EDGE safety mechanism is activated with a simple one-handed technique after injection: the needle is locked inside the protective sheath with an audible click and the entire device is then disposed of in a sharps container. The device is engineered to provide cost-effective, safety-engineered solutions for routine hypodermic injections and fluid withdrawal in a wide range of clinical applications while minimising dead space and maintaining clear bevel orientation and bold, distinct syringe markings.
Bnefits
Integrated safety-engineered design to help reduce potential for needlestick injuries by minimising critical exposure time.
Simple, one-handed activation of the hinged safety sheath for ease of use and compliance with sharps safety protocols.
Low dead space design to minimise medication waste during injection or aspiration.
Bold, distinct syringe markings (when used with matching EDGE safety syringe) to support accurate dosing.
Bevel orientation indicator and fixed bevel-up position to support consistent needle positioning.
Entire device colour-coded to ISO standard gauge colours for rapid identification (pink for 18G).
Sterile, single-use device designed to meet NIOSH/CDC recommendations for needle safety devices.
Engineered for cost-effective sharps safety while maintaining clinical performance.
Indications
For hypodermic injection of fluids such as medications, vaccines and other parenteral solutions.
For withdrawal of blood or other body fluids via hypodermic access when clinically indicated.
Use in general medical, surgical, emergency, anaesthetic and outpatient settings where an 18G needle is appropriate.
Applications requiring a larger-bore needle for rapid injection or aspiration, reconstitution and drawing up of viscous medications or solutions.
Use where a manual, hinged safety needle is required to support sharps injury prevention policies.
10 boxes per shipping case (total 1000 needles per case for code 401815).
Outer case labelled with product code 401815, gauge/length (18G x 1.5"), colour (pink), lot number and expiry date.
Usage
Open the sterile blister pack immediately before use and remove the device without touching the needle or safety sheath.
Attach the Luer hub of the safety needle securely to a compatible Luer syringe, taking care not to damage the safety mechanism.
With the needle bevel up, remove the needle cap by pulling it straight off without twisting, and draw up medication as required.
Expel any air from the syringe and administer the injection according to local clinical protocols and best practice.
After withdrawal of the needle from the patient, keep your free hand behind the needle at all times and do not attempt to recap.
Activate the Needle-Pro EDGE safety mechanism using a one-handed technique by gently pressing the safety sheath against a flat, stable surface until an audible click confirms the needle is locked inside the sheath.
Visually confirm that the needle tip is fully engaged within the protective sheath and cannot be exposed.
Immediately dispose of the entire device (needle and syringe) in an approved sharps container after activation.
Do not reuse, re-sterilise, bend or break the needle before disposal.
Contraindications
Do not use if the sterile package is open, damaged or has been previously compromised.
Not for reuse; single-use only. Reuse may lead to infection, dullness or failure of the safety mechanism.
Do not use in patients with known hypersensitivity or allergy to stainless steel or any material in the device.
Not suitable for use in applications requiring specialised needles (e.g. spinal, epidural, intravenous catheter placement) where product-specific devices are recommended.
Do not use if the safety mechanism appears damaged or does not function as described in the instructions for use.
Adverse Effects
Local pain, bruising or minor bleeding at the injection site, as with all hypodermic needle procedures.
Potential for local tissue trauma or haematoma if insertion technique is suboptimal.
Risk of local infection or abscess formation at the injection site if aseptic technique is not followed.
Rare hypersensitivity or allergic reactions to device materials in susceptible individuals.
Potential needlestick injury to healthcare workers or others if the safety mechanism is not correctly activated or the device is mishandled.
Storage Conditions
Store in a clean, dry environment at room temperature, away from excessive heat and direct sunlight.
Keep in original packaging until point of use to maintain sterility and protect the safety mechanism.
Do not expose the sterile packs to moisture or chemicals that could compromise packaging integrity.
Do not use beyond the expiry date indicated on the packaging.
Keep out of the reach of children and unauthorised personnel.