Logo
HOME
All FeaturesClinic Management SoftwareHIPAA Compliant Medical Spa Software
BLOGFAQS
Register a ClinicRegister as a Practitioner
BOOK DEMO
Are you a Practitioner?

Join over 200+ clinics already growing with Consentz.

BOOK DEMO

Contacts

(UK) +44 (0) 208 050 3372

(US) +1 646 786 1949

contact@consentz.com

Consentz vs

  • Zenoti
  • AestheticsPro
  • Pabau
  • Aesthetic Record
  • Clinicsense
  • Nextech
  • Vagaro
  • GlowdayPRO
  • PatientNow
  • Mangomint
  • Boulevard

Features

  • Clinic Management
  • Patient Engagement
  • Photos and Records
  • Personalise
  • Analytics
  • Stock and Billing

Features

  • Marketing
  • Medical Templates
  • FAQs
  • Blog
  • Articles
  • Support
  • Terms & Conditions
  • Partners
  • Privacy Policy
  • Sitemap

Get the app

Download Consentz on the App Store
Consentz

Find qualified healthcare and aesthetic practitioners in your area. Verified profiles, authentic reviews, and regulatory compliance.

For Practitioners

  • Join Directory
  • Update Profile
  • Verification Process
  • Support

Directory

  • Aesthetic Treatments
  • Top Aesthetic Practitioners
  • Top Aesthetic Clinics
  • Accredited Clinics
  • Top Clinics by Treatment & City
  • Top Practitioners by Treatment & City
  • Aesthetic Product Brands
  • Aesthetic Product Categories

Clinics by Accreditation

  • CQC Accredited Clinics
  • HIS Accredited Clinics
  • HIW Accredited Clinics
  • JCCP Accredited Clinics
  • RQIA Accredited Clinics
  • Save Face Accredited Clinics

Practitioners by Accreditation

  • CQC Accredited Practitioners
  • HIS Accredited Practitioners
  • HIW Accredited Practitioners
  • JCCP Accredited Practitioners
  • RQIA Accredited Practitioners
  • Save Face Accredited Practitioners

Consentz Hub

  • Buyer Hub
  • Aesthetic Clinic Software
  • Templates
  • By City

© 2026 Consentz. All rights reserved.

  1. Home
  2. Products
  3. Quanta System
  4. quanta-duetto-mt-evo-laser-system-with-zimmer-cryo-6
Quanta Duetto MT EVO Laser System with Zimmer Cryo 6

Quanta Duetto MT EVO Laser System with Zimmer Cryo 6

Quanta System

Medical / Aesthetic Device
Mixed-technology Alexandrite & Nd:YAG dermatologic laser with external cold air skin cooling system

Certifications

  • CE Marked medical device system (laser) for appropriate indications, subject to regional regulatory clearances.
  • Zimmer Cryo 6: CE Marked cold air skin cooling device for use in conjunction with dermatologic and aesthetic procedures.
  • Must be operated in accordance with applicable laser safety standards (e.g. IEC/EN laser safety classifications) and local medical device regulations.
  • CE Marked medical device system (laser) for appropriate indications, subject to regional regulatory clearances.
  • Zimmer Cryo 6: CE Marked cold air skin cooling device for use in conjunction with dermatologic and aesthetic procedures.
  • Must be operated in accordance with applicable laser safety standards (e.g. IEC/EN laser safety classifications) and local medical device regulations.
Mixed-technology Alexandrite & Nd:YAG dermatologic laser with external cold air skin cooling system

Description

The Quanta Duetto MT EVO is a high-end mixed-technology dermatologic laser platform designed for hair removal, vascular treatments and skin rejuvenation. It combines Alexandrite 755 nm and Nd:YAG 1064 nm laser sources that can be delivered as single, sequential or simultaneous (mixed) emissions. This flexibility, together with large spot sizes, a wide range of pulse durations and high repetition rates, makes the system suitable for all skin phototypes and a wide spectrum of indications including permanent hair reduction, vascular lesions and non-ablative skin rejuvenation. When paired with the Zimmer Cryo 6 cold air system, the device offers powerful epidermal protection and analgesia by delivering continuous streams of cold air to the treatment area before, during or after laser exposure, enhancing patient comfort and safety while minimizing the risk of thermal injury.

Bnefits

  • Dual-wavelength mixed technology: Alexandrite 755 nm and Nd:YAG 1064 nm, usable in single, sequential or simultaneous mixed emission modes.
  • Treats a broad range of indications including permanent hair reduction, vascular lesions and skin rejuvenation with one platform.
  • Suitable for all skin types and tones (I–VI) and a wide range of hair types by tailoring wavelength, fluence, pulse width and emission mode.
  • Large spot sizes and fast repetition rates enable rapid treatment of large body areas.
  • Programmable fluence and pulse duration with adjustable sequences improve efficacy while optimizing patient safety.
  • Upgradeable with TWAIN IPL and other optional handpieces to expand treatment capabilities.
  • Zimmer Cryo 6 provides powerful, contact-free cold air skin cooling (air as low as approximately −30 °C at the nozzle) for significant pain reduction and epidermal protection.
  • Cold air cooling can be applied before, during and after laser pulses without interfering with the laser beam, improving comfort and reducing risk of burns.
  • Zimmer Cryo 6 uses filtered room air and requires no consumables, allowing continuous operation with minimal running costs.

Indications

  • Permanent hair reduction/removal on face and body for all skin phototypes (I–VI).
  • Treatment of benign vascular lesions such as telangiectasia, leg veins and other superficial vascular conditions (Nd:YAG 1064 nm).
  • Non-ablative skin rejuvenation and tightening using Nd:YAG parameters.
  • Treatment of certain benign pigmented lesions (depending on clinical protocol and configuration).
  • Reduction of pseudo-folliculitis barbae and prevention of ingrown hairs.
  • Zimmer Cryo 6: epidermal cooling and pain relief during dermatologic and aesthetic laser treatments, injections and other procedures.

Composition

  • Solid-state Alexandrite laser source (755 nm).
  • Solid-state Nd:YAG laser source (1064 nm).
  • Internal optics and beam delivery system with variable spot-size handpieces (e.g. 2–5 mm, 10 mm, 14 mm, 18 mm – exact configuration depends on package).
  • Integrated control console with touchscreen interface and software for mixed-technology emission control.
  • Footswitch, operator and patient safety eyewear and other standard laser safety accessories (depending on configuration).
  • Zimmer Cryo 6 cold air unit including compressor, refrigeration system, control electronics and 1.8 m treatment hose with optional focusing tips.

Formulation

Not publicly listed

Packaging

  • Main Duetto MT EVO laser console with dual-wavelength laser sources.
  • One or more variable spot-size treatment handpieces with fiber delivery and storage case (exact number and sizes depend on system configuration).
  • Integrated or external skin cooling interface/adapter for use with cold air cooling.
  • Zimmer Cryo 6 unit with glass/Plexiglas top, 1.8 m cooling hose and control panel (supplied when purchased as a combined system).
  • Standard accessories typically include: foot pedal, operator manual set, operator goggles and patient goggles, system cover and power cables (contents may vary by distributor).

Usage

  • Only trained and appropriately licensed medical or aesthetic professionals should operate the Duetto MT EVO and Zimmer Cryo 6 systems.
  • Perform a thorough medical history, skin and hair assessment and obtain informed consent prior to treatment.
  • Select the appropriate wavelength (755 nm, 1064 nm or mixed), fluence, pulse duration, spot size and emission mode based on indication, skin type and hair characteristics according to the manufacturer’s guidelines and clinical judgment.
  • Prepare the treatment area by cleansing the skin and shaving hair if performing hair removal; avoid active infections, open wounds or recent sunburn in the target area.
  • Provide certified protective eyewear to the patient and all personnel in the treatment room.
  • Position the Zimmer Cryo 6 nozzle 5–20 cm from the treatment area and select the desired airflow level; start cooling shortly before initiating laser pulses.
  • Deliver laser pulses in a systematic pattern, ensuring adequate overlap as recommended while monitoring skin response; adjust parameters if necessary for safety and comfort.
  • Maintain continuous or intermittent cold air flow from the Cryo 6 before, during and after laser application to minimize discomfort and reduce risk of epidermal injury.
  • After treatment, continue cooling for a short period if needed, then apply appropriate post-treatment care (e.g. soothing topical products) and advise strict photoprotection.
  • Schedule follow-up sessions depending on the indication (e.g. hair removal typically requires multiple sessions spaced several weeks apart).
  • Perform regular maintenance, safety checks and calibration as recommended by the manufacturer or authorized service provider; keep air filters of the Cryo 6 clean and empty the condensation collector at the recommended intervals.

Contraindications

  • Active infections, open wounds or inflammatory skin diseases in the intended treatment area.
  • Recent significant sun exposure, sunburn or use of tanning beds in the treatment area without adequate recovery time.
  • History of keloid formation or abnormal scarring, or severely impaired wound healing.
  • Known photosensitivity disorders or use of strong photosensitizing medications, unless carefully assessed and cleared by a physician.
  • Pregnancy as a general precaution, unless local regulations and clinical judgment explicitly allow treatment.
  • Uncontrolled systemic disease or conditions that the treating physician considers unsafe for laser procedures.
  • Patients unable or unwilling to comply with eye protection, treatment instructions or post-treatment sun avoidance.
  • History of hypersensitivity to extreme cold (for use of Zimmer Cryo 6), such as cold urticaria or cryoglobulinemia.

Adverse Effects

  • Transient erythema (redness), edema and mild discomfort or burning sensation in the treated area.
  • Temporary darkening or lightening of the skin (post-inflammatory hyper- or hypopigmentation), particularly if sun exposure is not adequately avoided.
  • Crusting, blistering or superficial burns if parameters or technique are inappropriate or if there is inadequate epidermal protection.
  • Rare risk of scarring or textural changes with improper use or in highly susceptible patients.
  • With Zimmer Cryo 6, excessive cooling or prolonged exposure at very close distances may rarely cause cold-related skin irritation or, in extreme cases, frostbite if used contrary to guidelines.

Storage Conditions

  • Install and store the Duetto MT EVO and Zimmer Cryo 6 systems in a clean, dry, well-ventilated clinical environment.
  • Keep units on stable, level surfaces with sufficient clearance around ventilation inlets and outlets.
  • Avoid exposure to excessive dust, moisture, corrosive vapors and temperature extremes outside the manufacturer’s specified operating and storage ranges.
  • Ensure power supply and grounding meet the manufacturer’s electrical specifications.
  • Turn off and unplug devices before long periods of non-use or when performing certain maintenance procedures.

Duration

Individual session duration varies by indication and treatment area size; small areas may take only a few minutes, while large body areas can take 20\u201360 minutes. Hair removal and many vascular or rejuvenation indications typically require multiple sessions (commonly 4\u20138 or more) spaced several weeks apart for optimal results.

Onset

Initial clinical improvements, such as hair shedding or vessel clearance, are often visible within days to weeks after treatment, with progressive results over the course of repeated sessions. Pain reduction and epidermal protection from Zimmer Cryo 6 cooling are immediate during use.
PriceLink
£17000https://laserandaesthetics.co.uk/used-equipment/like-new-lynton-3juve-system
PriceLink
£15999https://laserandaesthetics.co.uk/used-equipment/like-new-lyntondeka-onda-coolwaves
PriceLink
£45000https://laserandaesthetics.co.uk/used-equipment/like-new-quanta-duetto-mt-evo-laser

Browse more Medical / Aesthetic Device

Used Quanta Q plus C EVO

Used Quanta Q plus C EVO

Laserandaesthetics

Used Quanta Q plus C EVO

Medical and Aesthetic Equipment
  • £32000
  • £28000
  • 2 more

Top Treatments

Acne

Acne
Acne

Aesthetic Skin Consultation

Aesthetic Skin Consultation
Aesthetic Skin Consultation

Alopecia

Alopecia
Alopecia

Anti Wrinkle Treatment

Anti Wrinkle Treatment
Anti Wrinkle Treatment

Aqualyx

Aqualyx
Aqualyx

Aviclear

Aviclear
Aviclear

B12 Injection

B12 Injection
B12 Injection

Birthmarks

Birthmarks
Birthmarks

Botox

Botox
Botox

Breast Augmentation

Breast Augmentation
Breast Augmentation

Cheek Enhancement

Cheek Enhancement
Cheek Enhancement

Top Cities in the UK

4QR
Aberaeron
Aberdare
Aberdeen
Aberfeldy
Abergavenny
Aberpwll
Abertillery
Aberystwyth
Abingdon
Accrington
Airdrie
Alderley
Alderminster
Alexandria