Classified by Sarstedt as an in Vitro diagnostic (IVD) accessory for venous blood collection.
CE certified under manufacturer’s self Declaration for IVD devices in the EU/EEA and UK markets (as indicated in Sarstedt product data).
Manufactured under an ISO 13485 Compliant quality management system for medical devices and IVDs.
Supplied sterile, non Pyrogenic/endotoxin Free, with sterility achieved by validated gamma irradiation processes.
Conforms to Sarstedt’s internal purity standards for clinical laboratory blood collection components.
Classified by Sarstedt as an in Vitro diagnostic (IVD) accessory for venous blood collection.
CE certified under manufacturer’s self Declaration for IVD devices in the EU/EEA and UK markets (as indicated in Sarstedt product data).
Manufactured under an ISO 13485 Compliant quality management system for medical devices and IVDs.
Supplied sterile, non Pyrogenic/endotoxin Free, with sterility achieved by validated gamma irradiation processes.
Conforms to Sarstedt’s internal purity standards for clinical laboratory blood collection components.
Blood Collection Luer Adapter
Description
The Multi-adapter - Luer for S-Monovette is a sterile, single-use connection adapter designed by Sarstedt for the S-Monovette blood collection system. With a standard Luer connection and a compact 37 mm translucent PET body, it enables safe, low-dead-space connection between S-Monovette tubes and a wide range of Luer-based devices such as venous cannulas, butterfly needles and three-way stopcocks. Each adapter is individually blister-packed and supplied in boxes of 100 pieces for routine clinical and laboratory use.
Bnefits
Provides a universal Luer interface for the S-Monovette blood collection system, ensuring compatibility with standard Luer-based devices.
Enables safe, closed blood collection from venous cannulas, butterfly sets and three-way stopcocks without changing the collection system.
Sterile and non-pyrogenic/endotoxin-free, supporting safe and hygienic blood sampling.
Single-use, individually blister-packed design helps maintain sterility until the point of use.
Translucent PET construction allows visual inspection of the adapter and fluid path.
Short 37 mm length minimises dead volume while maintaining good handling characteristics.
Designed specifically for S-Monovette, providing a secure fit and reliable performance within the system.
Supplied in boxes of 100 adapters, suitable for high-throughput hospital, clinic and laboratory environments.
Indications
Use as a connection adapter between S-Monovette blood collection tubes and medical devices with a standard Luer connection.
Venous blood collection via Luer-compatible devices such as venous indwelling cannulas, butterfly needles and three-way stopcocks.
Routine venous blood sampling in hospitals, outpatient clinics, general practice surgeries, laboratories and veterinary practices using the S-Monovette system.
Situations where a sterile, single-use Luer adapter is required to connect S-Monovette to existing Luer-based access devices.
Latex-free plastic construction (no natural rubber latex).
Formulation
Medical device type: in-vitro diagnostic (IVD) accessory for venous blood collection.
Design: Luer; suitable for S-Monovette; connection: Luer.
Length of product: 37 mm.
Translucent PET body providing a rigid, low-dead-space connector.
Supplied sterile, non-pyrogenic/endotoxin-free for single use.
Intended for use as an adapter only, with no pharmacological activity.
Packaging
Individually blister-packed adapters (1 adapter per sterile blister).
100 sterile blisters per box (100 adapters per box).
Typical shipping configuration: 100/box, 1,000/case in Sarstedt logistics documentation.
Outer carton labelled with product name, order number 14.1205, PZN 6796193 (in some markets), quantity, lot number and expiry date.
Packaging maintains sterility until opening and is suitable for use in clinical and laboratory environments.
Usage
Use only by trained healthcare or laboratory professionals familiar with venous blood collection and the S-Monovette system.
Before use, inspect the blister and adapter; do not use if the blister is damaged, opened or if the adapter is cracked, deformed or contaminated.
Open the blister immediately before use, maintaining aseptic technique to prevent contamination of the Luer surfaces.
Attach the Multi-adapter firmly to the S-Monovette in accordance with the S-Monovette instructions for use, ensuring a secure Luer connection.
Connect the Luer end of the adapter to the corresponding Luer fitting on the access device (e.g. venous cannula, butterfly set or three-way stopcock) using standard Luer technique.
Perform venous blood collection according to institutional protocols and the S-Monovette user guide, avoiding excessive bending or torque on the adapter.
After collection, disconnect the adapter carefully from both the S-Monovette and the Luer device, following local infection-prevention and sharps-safety procedures.
Dispose of the used adapter immediately into an appropriate sharps or clinical waste container; do not reuse or resterilise.
Refer to Sarstedt’s S-Monovette instructions and adapter product specification for any additional handling and safety guidance.
Contraindications
Do not reuse; reuse or resterilisation can lead to infection risk, cross-contamination or mechanical failure.
Do not use if the sterile blister has been opened or damaged prior to use.
Do not use if the adapter is visibly damaged, deformed or contaminated.
Not intended for direct infusion of drugs or solutions as a stand-alone device; use only as an adapter within validated blood collection procedures.
Not suitable for applications outside the specified compatibility with S-Monovette and standard Luer systems.
Adverse Effects
When used as intended as a passive connector, the adapter itself is not expected to cause direct patient adverse effects.
Incorrect use or loose connections may result in blood leakage or disconnection, increasing exposure risk for staff and potential sample loss.
Failure to maintain aseptic technique may increase the risk of infection transmission to patients or healthcare workers.
Reuse or improper handling could increase the risk of haemolysis, sample contamination or device failure.
Storage Conditions
Store in a clean, dry environment at ambient room temperature within normal clinical or laboratory ranges, as specified by the manufacturer.
Keep adapters in their original box and individual blisters until use to maintain sterility and protect from dust and mechanical damage.
Avoid exposure to extreme temperatures, direct sunlight or high humidity that may deform or degrade the PET material.
Do not store near solvents or aggressive chemicals that could compromise the plastic.
Do not use after the expiry date printed on the packaging.
Duration
Single-use device; intended for one blood collection procedure only and must be discarded immediately after use.
Onset
Immediate mechanical function upon correct connection to the S-Monovette and the Luer-based device; no pharmacological effect.