Aurelia Bold MAX Powder Free Black Nitrile Gloves   Box of 50

Aurelia Bold MAX Powder Free Black Nitrile Gloves Box of 50

Aurelia

Nitrile Gloves
  • PPE Regulation (EU) 2016/425, Category III.
  • Medical Device Regulation (EU) 2017/745, and legacy Directive 93/42/EEC (medical examination glove).
  • BS EN 455 Parts 1–4: Medical gloves for single use (freedom from holes, physical properties, biological evaluation, shelf life).
  • BS EN ISO 374 1:2016 (and amendments) Type B JKPT – protective gloves against dangerous chemicals.
  • BS EN ISO 374 5:2016 – protective gloves against microorganisms including viruses.
  • EN 420:2003 + A1:2009 / EN ISO 21420 – general requirements and test methods for protective gloves.
  • BS EN 1186:2002 – materials and articles in contact with foodstuffs (food contact approved).
  • Manufactured under ISO 9001:2015 and ISO 13485:2016 certified quality management systems.
Black heavy-duty diamond-textured nitrile examination gloves

Description

Aurelia Bold MAX Powder Free Black Nitrile Gloves are heavy-duty, premium black nitrile examination gloves engineered for high tensile strength and superior chemical and puncture resistance. With a 6.0 mil (approx. 0.15 mm) nominal thickness and a full diamond-textured surface, they deliver exceptional grip and control, especially in wet or oily conditions. These non-sterile, ambidextrous, latex-free gloves are supplied in boxes of 50 Large-size gloves, are powder free, and are tested as both medical examination gloves and Category III PPE against chemicals and microorganisms.

Bnefits

  • Heavy-duty 7.5 g nitrile construction (approx. 6 mil) provides excellent durability, puncture resistance and tensile strength.
  • Full diamond-textured surface offers unrivalled grip and control, particularly in wet, oily or greasy environments.
  • Premium nitrile formulation delivers superior chemical resistance compared to latex or vinyl examination gloves within tested ranges.
  • Powder-free and latex-free design reduces the risk of powder-related contamination and latex-associated allergies.
  • Black colour helps mask stains such as oil, grease, ink, dyes or blood, and offers high contrast for contamination visibility.
  • Ambidextrous design and beaded cuff make donning and removal easier while improving cuff strength.
  • Medical grade with AQL 1.5 and tested to EN 455 1–4 for use as single-use examination gloves.
  • Certified to EN ISO 374-1, 2, 4, 5 for protection against dangerous chemicals and microorganisms, including viruses (Type B JKPT).
  • Food-contact compliant (BS EN 1186), suitable for food handling applications when required.

Indications

  • Use as non-sterile examination gloves in medical, dental and healthcare settings where heavy-duty protection is desirable.
  • Aesthetic medicine, dermatology, tattooing, piercing and beauty procedures requiring robust, dark-coloured gloves with excellent grip.
  • Automotive, mechanical, engineering and maintenance tasks with exposure to oils, grease, fuels and dirt.
  • Industrial, janitorial, cleaning and facilities management tasks requiring strong disposable chemical-resistant gloves within tested EN ISO 374 limits.
  • Laboratory and pharmaceutical environments where chemical splash, biological materials and contamination risks are present.
  • Food handling and preparation tasks where food-contact-approved gloves are required.
  • Applications where metal-free, latex-free examination gloves are preferred for allergy or process reasons.

Composition

  • Material: Nitrile butadiene rubber (NBR), black, latex free.
  • Surface: Full diamond-textured grip pattern for enhanced traction.
  • Thickness (single wall, minimum values): approx. 0.20 mm at fingers, 0.17 mm at palm, 0.09 mm at cuff (per product sheet).
  • Nominal weight: 7.5 g ± 0.2 g per glove (reference size).
  • Length: Minimum 240 mm for all sizes.
  • Cuff: Beaded cuff to improve tear resistance and facilitate donning.
  • Powder content: Powder free (no donning powder added).
  • Colour: Black.

Formulation

  • Non-sterile, single-use nitrile examination glove.
  • 6 mil heavy-duty nitrile formulation for extra strength and durability.
  • Diamond-textured external surface over fingers, palm and hand.
  • Ambidextrous design to fit either hand.
  • Beaded cuff to reduce tearing and prevent roll-down.
  • AQL 1.5 for pinhole defects, medical grade.
  • Available sizes: Medium, Large, Extra Large, XXL; this SKU refers to Large.

Packaging

  • Box containing 50 single-use black nitrile examination gloves (by count).
  • Inner box dimensions approximately 240 x 130 x 70 mm.
  • Outer shipping case: 10 inner boxes per case (10 x 50 gloves = 500 gloves), approx. 360 x 270 x 255 mm.
  • Packaging clearly marked with size (L), lot number, manufacture date, expiry date, and regulatory/standard markings.
  • Barcodes (EAN-13) for Large: inner box 955-500211-3070; outer case 1955-500211-3077 (per manufacturer product sheet).

Usage

  • Check the box and inner packaging before use; do not use if packaging is damaged or if the product is past its expiry date.
  • Ensure hands are clean and dry; remove jewellery or trim nails that could puncture or tear the glove.
  • Select the correct size (Large) to ensure a snug, comfortable fit without excessive stretching.
  • To don, remove a glove from the dispensing box by the cuff, insert the fingers and thumb, then pull the beaded cuff over the wrist, smoothing out any folds.
  • Repeat for the other hand, maintaining aseptic technique where clinically indicated.
  • During use, avoid contact with chemicals outside the glove’s validated EN ISO 374 resistance list; follow local COSHH/risk assessments.
  • Change gloves between patients, between different tasks on the same patient, or immediately if the glove is torn, punctured, heavily soiled or after contact with aggressive chemicals.
  • To remove, grasp the outside of one glove near the wrist and peel it off inside out, holding it in the gloved hand; slide an ungloved finger under the cuff of the remaining glove and peel it off over the first glove without touching the contaminated exterior.
  • Dispose of used gloves safely according to local clinical, hazardous or general waste requirements; do not reuse single-use gloves.
  • Wash or sanitise hands after glove removal as per hand-hygiene protocols.

Contraindications

  • Known or suspected hypersensitivity or allergy to nitrile or any of the glove’s compounding ingredients or colourants.
  • Use in procedures that require sterile surgical gloves; Bold MAX gloves are non-sterile examination gloves.
  • Use with highly aggressive chemicals, solvents or cytotoxic agents not covered by the glove’s EN ISO 374 chemical resistance data or manufacturer guidance.
  • Use in high-heat, open flame or molten-material environments; nitrile examination gloves are not flame- or heat-resistant PPE.
  • Do not use if gloves show signs of degradation such as brittleness, stickiness, tears, holes, discolouration or if the packaging is compromised.

Adverse Effects

  • Possible skin irritation, contact dermatitis or allergic reactions in sensitised individuals exposed to nitrile compounds, accelerators or dyes.
  • Skin maceration or excessive sweating if gloves are worn continuously for extended periods without breaks.
  • Reduced tactile sensitivity and fine motor control if incorrect size is used or more than one glove is worn per hand.
  • Inadequate protection and increased risk of exposure if gloves are reused, worn beyond their intended duration or used with incompatible chemicals.
  • Potential tearing or puncture if used with sharp instruments, long nails or jewellery, compromising barrier integrity.

Storage Conditions

  • Store in a cool, dry place away from direct sunlight, UV sources and excessive heat.
  • Recommended storage temperature typically between 5°C and 25°C; avoid freezing temperatures and high heat.
  • Keep away from ozone generators and chemicals, oils or solvents that may degrade nitrile.
  • Store in the original packaging until use to protect from dust, moisture and contamination.
  • Do not use after the expiry date printed on the packaging, in line with EN 455-4 shelf-life requirements.

Duration

Single-use disposable glove intended for one task or patient contact episode only; must be changed between tasks, between patients, or whenever damaged or visibly contaminated.

Onset

Provides immediate barrier protection and grip enhancement upon correct donning.