MediPro Black Nitrile Gloves Box of 100 Small
MediPro
GlovesDisposable nitrile examination gloves
Certifications
- PPE Regulation (EU) 2016/425 Cat III
- AQL 1.5
- EN 455 (Medical gloves for single use)
- EN 374 1 (Protective gloves against dangerous chemicals and micro Organisms)
- EN ISO 374 2
- EN ISO 374 4
- EN 374 5
- EN 1186:2002 (Food contact)
- ISO 9001:2015 Quality Management System
- ISO 13485:2016 Medical Devices Quality Management System
- ISO 10993 5 (Biological evaluation – cytotoxicity)
- Food Safe for contact with all food types
- PPE Regulation (EU) 2016/425 Cat III
- AQL 1.5
- EN 455 (Medical gloves for single use)
- EN 374 1 (Protective gloves against dangerous chemicals and micro Organisms)
- EN ISO 374 2
- EN ISO 374 4
- EN 374 5
- EN 1186:2002 (Food contact)
- ISO 9001:2015 Quality Management System
- ISO 13485:2016 Medical Devices Quality Management System
- ISO 10993 5 (Biological evaluation – cytotoxicity)
- Food Safe for contact with all food types
Disposable nitrile examination gloves
Description
Premium quality, non-sterile black nitrile examination gloves supplied in a box of 100 small-sized gloves. These latex-free, powder-free gloves are designed to offer greater tensile strength and protection than both latex and vinyl, while remaining comfortable and flexible for extended wear. They are Cat III PPE under EU 2016/425, food-safe, and suitable for use across healthcare, aesthetic, tattoo, veterinary, and general examination settings.
Bnefits
- Premium quality black nitrile examination gloves
- Higher tensile strength and protection than latex and vinyl gloves
- Latex-free, reducing risk of latex-related allergic reactions
- Powder-free and non-sterile for general examination and procedure use
- Cat III PPE compliant under Regulation (EU) 2016/425
- AQL 1.5 for reliable barrier performance
- Food-safe for handling all food types
- Textured fingers for improved grip and handling of instruments
- Beaded cuff helps prevent roll-down and improves donning
- Comfortable and flexible for prolonged wear
Indications
- Routine medical and clinical examinations
- Non-sterile procedures requiring hand barrier protection
- Aesthetic and cosmetic procedures (e.g. injectables, skin treatments) where non-sterile examination gloves are appropriate
- Tattoo and piercing studios
- Veterinary examinations and procedures
- Laboratory, cleaning and general infection control tasks
- Food handling and preparation where food-safe gloves are required
Composition
- Nitrile butadiene rubber (synthetic nitrile)
- Latex-free
- Powder-free (no donning powder present)
Formulation
- Nitrile examination glove, powder-free, latex-free
- Textured fingers for enhanced grip
- Beaded cuff design
- Length: approximately 240 mm
- Palm width (small size): approximately 85 mm
- Palm thickness: approximately 0.09 mm (± 0.02)
- Approximate glove weight (small): 3.9 g
Packaging
- Box of 100 small-sized black nitrile examination gloves
- Non-sterile examination-grade packaging
- Typical dispenser-style cardboard box for single-glove withdrawal
Usage
- Select the correct size (small) to ensure a snug but comfortable fit.
- Inspect the glove for visible damage or defects before use; do not use damaged gloves.
- With clean, dry hands, remove one glove from the dispenser and insert fingers, then pull over the hand ensuring the cuff sits securely at the wrist.
- Repeat for the second hand, avoiding touching the outside surface of the glove as much as possible.
- Use gloves for a single procedure or task; change gloves between patients and between different tasks on the same patient.
- Avoid contact with sharp objects that may puncture the glove.
- After use, grasp the outside of one glove near the wrist, peel off turning it inside out, and hold it in the gloved hand.
- Slide ungloved fingers under the wrist of the remaining glove, avoiding contact with the outer surface, and peel off turning it inside out over the first glove.
- Dispose of used gloves in accordance with local clinical or hazardous waste protocols.
- Wash or sanitise hands after glove removal.
Contraindications
- Known hypersensitivity or allergy to nitrile or any glove component.
- Not suitable where sterile surgical gloves are specifically required.
- Should not be used if the glove is visibly damaged, degraded, or past its expiry date.
Adverse Effects
- Potential for local skin irritation or contact dermatitis in sensitive individuals.
- Rare allergic reactions to nitrile or other glove components.
- Excessive sweating or maceration of the skin with prolonged, continuous wear.
Storage Conditions
- Store in a cool, dry place away from direct sunlight and sources of ozone or heat.
- Keep in original packaging until use to protect from dust and contamination.
- Avoid storage in temperatures outside the range recommended on the outer packaging (typically room temperature conditions).
- Do not use after the expiry date printed on the packaging.
Duration
Single-use only; gloves should be worn for the duration of a single procedure or task and changed between patients and tasks.
Onset
Immediate barrier protection upon donning intact gloves.