  • CE Marked occupational footwear produced under Cortina Group / Safety Jogger quality management systems (ISO 9001 Based).
  • EN ISO 20347 O1 SRC ESD certified occupational footwear (non Safety toe) with slip resistance and antistatic / ESD properties.
  • SRC slip Resistance classification (SRA + SRB) confirming performance on ceramic and steel surfaces with appropriate test solutions.
  • Heel energy absorption compliant with EN ISO 20347 requirements for occupational footwear.
  • Free of harmful substances according to EN ISO 20347 specifications for breathable, high Quality inner lining.
  • Manufacturer literature also cites EN ISO 20347:2022 O1 SR ESD HRO and ASTM F2892:2018 compliance for certain markets.
Medical footwear \u2013 slip-on leather nursing/work shoe

Description

The Oxypas Motion Roy Slip-on Leather Nursing Shoe for Men is a lightweight, slip-on professional work shoe designed specifically for healthcare and other standing-intensive occupations. Part of the Oxypas / Safety Jogger Professional range, Roy combines a genuine leather upper with a feather-light EVA midsole and a slip-resistant SRC rubber outsole to provide comfort, safety and durability during long shifts. The shoe features a breathable Coolmax lining to keep feet cool and dry, an anatomic removable insole with shock-absorbing properties, and antistatic ESD protection to safely dissipate electrostatic charge. CE-marked and EN ISO 20347 certified (O1 SRC ESD), Roy offers exceptional grip on wet and dry floors and is suitable for hospital environments as well as hospitality, catering, cleaning, wellness and other workplaces where non-slip, anti-static footwear is required.

Bnefits

  • Comfortable, lightweight slip-on nursing and work shoe designed for male healthcare professionals and other standing-intensive roles.
  • Genuine leather upper provides durability, professional appearance and easy wipe-clean maintenance.
  • Feather-light EVA midsole offers effective shock absorption, helping to reduce fatigue in feet, legs and lower back during long shifts.
  • Breathable Coolmax lining helps wick moisture away from the foot, keeping feet cool, dry and comfortable.
  • SRC-rated anti-slip rubber outsole delivers exceptional grip on both wet and dry surfaces, reducing the risk of slips and falls.
  • Antistatic ESD (Electrostatic Dissipation) properties safely discharge static electricity, suitable for environments with sensitive equipment.
  • Anatomic removable insole with cushioning supports the arch and heel, allowing orthotic replacement if required.
  • Slip-on loafer design with elastic inserts at the instep provides secure fit and quick on/off convenience.
  • CE-marked and EN ISO 20347 certified occupational footwear, free of harmful substances according to the standard.
  • Versatile style suitable for hospitals, clinics, catering, hospitality, cleaning and other professional environments where safe, comfortable footwear is essential.

Indications

  • Professional footwear for male nurses, doctors and other medical staff working in hospitals, clinics, care homes and outpatient settings.
  • Use in environments where non-slip, anti-static and easy-to-clean shoes are required, such as theatres, wards, laboratories, pharmacies and diagnostic departments.
  • Suitable work shoe for hospitality, catering, cleaning, wellness, spa and beauty professionals who spend long hours on their feet.
  • Recommended when lightweight, shock-absorbing and breathable footwear is needed to help reduce fatigue and improve comfort during prolonged standing and walking.
  • Appropriate for workplaces that require EN ISO 20347-certified occupational footwear with SRC slip-resistance and ESD properties.

Composition

  • Upper: Genuine leather (smooth, wipe-clean finish).
  • Lining: Coolmax breathable textile lining to manage moisture and temperature.
  • Midsole: Lightweight EVA (Ethylene Vinyl Acetate) providing cushioning and shock absorption.
  • Outsole: Slip-resistant rubber meeting SRC (SRA + SRB) slip-resistance standard.
  • Insole: Anatomic, removable cushioned footbed with shock-absorbing properties.
  • Antistatic / ESD components integrated into sole construction to allow controlled electrostatic discharge.
  • Elastic inserts at instep for slip-on fit (material typically elastic textile or elasticized leather).

Formulation

  • Product type: Non-sterile, reusable occupational work shoe (loafer style).
  • Model: Oxypas Roy / Motion Roy (men’s slip-on leather nursing shoe).
  • Safety standard: EN ISO 20347 O1 SRC ESD (occupational footwear) – non-safety toe, slip-resistant, anti-static with energy absorption in the heel.
  • Additional standard (manufacturer leaflet): O1 SR ESD HRO, EN ISO 20347:2022 and ASTM F2892:2018 (region-dependent labelling).
  • Heel energy absorption: Enhanced heel cushioning to meet EN ISO 20347 requirements (approx. 20 J or more, depending on test size).
  • Approximate weight: about 310 g per shoe (varies with size).
  • Heel height: approx. 3 cm.
  • Fit: Men’s professional loafer with orthopaedic fitting support (Neskrid collaboration referenced by manufacturer).
  • Intended use: Occupational footwear for indoor/outdoor professional environments, not a safety toe cap shoe.

Packaging

  • Supplied as a pair of shoes (left and right) per retail box.
  • Packaged in branded Safety Jogger / Oxypas shoe box with model name (ROY), size, colour and standards marking (EN ISO 20347 O1 SRC ESD).
  • Outer shipping cartons contain multiple pairs by size and colour for institutional orders.
  • Labelling includes CE mark, EN ISO 20347 category, ESD symbol, size, manufacturing batch/date code and care instructions.

Usage

  • Select the correct size using the manufacturer’s size chart; Roy is typically available in men’s EU sizes (e.g. 39–46/47) and may fit slightly generously to allow all-day wear.
  • On first use, try the shoes indoors to confirm fit; there should be adequate toe room, a secure heel fit and comfortable instep contact.
  • Wear with suitable socks to optimise comfort, manage perspiration and reduce friction.
  • Slip the shoe on using the elasticated instep; ensure the heel is properly seated and the shoe feels secure before walking.
  • Use Roy in appropriate work environments where EN ISO 20347 O1 SRC ESD footwear is acceptable; it does not contain a safety toe cap and should not replace required safety footwear in high-risk environments.
  • Clean the leather upper regularly by wiping with a damp cloth and mild soap if necessary; do not use harsh solvents or corrosive cleaning agents.
  • Allow shoes to air dry naturally at room temperature after cleaning; do not place them on radiators, heaters or in direct intense heat sources.
  • If required, remove the anatomic insole to air or replace with custom orthotics, ensuring that replacement insoles do not compromise fit or ESD properties.
  • Inspect the outsole tread regularly; replace the shoes if the tread is significantly worn or if slip-resistance appears reduced.
  • Replace the shoes if there are signs of structural damage (cracks, sole separation, severe deformation) or if ESD performance is suspected to be compromised.
  • Follow any additional care and usage instructions provided on the product label or in manufacturer literature.

Contraindications

  • Not suitable for workplaces that require protective safety toe caps (e.g. EN ISO 20345 S-category safety footwear) or puncture-resistant midsoles.
  • Not appropriate for users with known hypersensitivity or allergy to leather, rubber, EVA or other components of the shoe.
  • Should not be used in environments that require electrically insulating (non-conductive) footwear, as Roy is antistatic / ESD and designed to dissipate static electricity.
  • Do not use if the shoe is visibly damaged, excessively worn, or if the outsole has lost most of its tread, as slip-resistance and ESD performance may be compromised.
  • Users with significant foot deformities or medical conditions affecting gait should seek professional advice before using standard occupational footwear.

Adverse Effects

  • Possible discomfort, pressure points or blisters if the incorrect size is chosen or shoes are not properly broken in.
  • Potential for foot perspiration or odour if worn for long periods without appropriate socks or adequate drying between uses.
  • In rare cases, contact dermatitis or irritation in individuals sensitive to leather, dyes, adhesives or other materials used in the shoe.
  • Use of worn or damaged shoes may increase the risk of slips, trips or falls due to reduced tread performance or impaired support.
  • Insufficient drying after cleaning may result in temporary dampness discomfort or contribute to skin maceration with prolonged wear.

Storage Conditions

  • Store in a cool, dry, well-ventilated area away from direct sunlight and excessive heat sources.
  • Allow shoes to dry completely before storage, especially after cleaning or exposure to moisture.
  • Avoid prolonged exposure to oils, solvents or corrosive chemicals that may degrade leather, EVA or rubber components.
  • Do not stack heavy objects on top of the shoes to prevent deformation.
  • For long-term storage, keep in the original shoe box or a breathable container to protect from dust and accidental damage.

Duration

Roy shoes are intended as reusable occupational footwear for daily use over an extended period. Service life depends on frequency of use, body weight, working conditions and maintenance. They should be replaced when the outsole tread is worn, cushioning is significantly reduced, visible damage occurs or institutional footwear replacement policies require it.

Onset

Comfort, slip-resistance and ESD protection are provided immediately upon wearing the shoes in accordance with sizing, fit and workplace conditions.