9600 Power Adapter Replacement Kit

9600 Power Adapter Replacement Kit

Welch Allyn

Medical equipment accessory
  • Supplied as an OEM replacement part for the CE Marked Welch Allyn 9600 Plus Calibration Tester; conformity of the overall system is documented in the device’s Declaration of Conformity and associated product documentation.
  • Designed and manufactured under Welch Allyn / Hillrom quality management systems applicable to medical electrical equipment and accessories.
Power adapter replacement kit for Welch Allyn 9600 Plus Calibration Tester

Description

The 9600 Power Adapter Replacement Kit is an original Welch Allyn replacement power supply kit for the Welch Allyn 9600 Plus Calibration Tester (product number 01802-110). Supplied as a power adapter with mains plug kit, it is designed to safely provide AC mains power to the 9600 Plus Calibration Tester and to replace the original adapter shipped with certain units in a defined serial number range. Using the correct adapter helps prevent permanent damage to the calibration tester and ensures reliable operation when verifying the calibration of compatible thermometers (such as Welch Allyn SureTemp Plus and Braun ThermoScan PRO models used with the 9600 Plus Calibration Tester).

Bnefits

  • Genuine Welch Allyn OEM replacement power adapter kit for the 9600 Plus Calibration Tester
  • Ensures the calibration tester is powered safely and correctly from mains power
  • Specifically intended to replace the original power adapter supplied with certain 9600 Plus Calibration Testers that could damage the unit if used
  • Helps protect the calibration tester from permanent damage due to incompatible power supplies
  • Supports reliable operation of the 9600 Plus Calibration Tester used to verify thermometer calibration
  • Supplied as a complete adapter and mains plug kit for straightforward replacement and installation
  • Compatible with Welch Allyn 9600 Plus Calibration Tester units within specified serial number ranges (and as directed by Welch Allyn service communications)

Indications

  • Replacement of the existing power adapter supplied with certain Welch Allyn 9600 Plus Calibration Tester units (product number 01802-110) as instructed by Welch Allyn
  • Provision of appropriate mains power for a Welch Allyn 9600 Plus Calibration Tester whose original adapter is missing, damaged, or identified as needing replacement
  • Use in service and clinical engineering departments to maintain safe and reliable operation of 9600 Plus Calibration Testers used for thermometer calibration verification

Composition

  • Welch Allyn 9600 Plus Calibration Tester AC power adapter (low-voltage DC output cable with device connector)
  • Mains plug kit for connection to wall power (region-appropriate mains plug as supplied)
  • Integral housing with fixed mains prongs or plug interface (depending on kit configuration)
  • Insulated low-voltage cable and molded connector designed to mate with the 9600 Plus Calibration Tester power input

Formulation

  • Medical equipment accessory consisting of an external AC-to-DC power adapter module and mains plug kit
  • Designed for use exclusively with the Welch Allyn 9600 Plus Calibration Tester (product 01802-110) and specified serial number ranges as per Welch Allyn instructions
  • External power supply with fixed low-voltage DC cable and plug designed to match the calibration tester’s power input jack
  • Intended for continuous connection to mains during use of the calibration tester in clinical engineering or biomedical environments

Packaging

  • Single 9600 Plus Calibration Tester power adapter with mains plug kit in one package
  • Packaged with multi-language instruction sheet / user notice indicating its purpose as a replacement power adapter
  • Labelled with OEM part number 105851 and relevant Welch Allyn product identification for the 9600 Plus Calibration Tester

Usage

  • Intended for use only with the Welch Allyn 9600 Plus Calibration Tester (product number 01802-110) and in accordance with the official Welch Allyn Instructions for Use and service notices.
  • Before installation, disconnect the 9600 Plus Calibration Tester from mains power and remove the original power adapter from both the wall outlet and the tester.
  • Discard the power adapter originally supplied with affected 9600 Plus Calibration Tester units in the specified serial number range, as instructed by Welch Allyn service documentation.
  • Connect the low-voltage plug of the replacement adapter kit to the power input jack on the 9600 Plus Calibration Tester, ensuring a secure connection.
  • Attach or use the appropriate mains plug from the kit (if supplied as a multi-plug kit) suitable for the local electrical outlet standard.
  • Plug the adapter into a suitable mains power outlet that meets the voltage and frequency requirements indicated on the adapter label.
  • Verify that the 9600 Plus Calibration Tester powers on and operates normally, following the tester’s User Manual for any subsequent setup or calibration checks.
  • Do not use this adapter to power devices other than the Welch Allyn 9600 Plus Calibration Tester, and do not modify the adapter or cable.
  • If there are any questions about compatibility or installation, contact the local Welch Allyn / Hillrom / Baxter service centre or representative.

Contraindications

  • Do not use the adapter with any device other than the Welch Allyn 9600 Plus Calibration Tester, unless explicitly specified by the manufacturer.
  • Do not use if the power adapter housing, mains plug, cable or connector appears damaged, frayed, cracked or otherwise compromised.
  • Do not use with mains outlets that do not match the voltage, frequency or plug type requirements indicated on the adapter label.
  • Do not use in environments where the adapter may be exposed to liquids, excessive moisture, flammable anaesthetic mixtures or explosive atmospheres, unless permitted by the device’s instructions and local regulations.

Adverse Effects

  • As a non-patient-contact electrical accessory, clinical adverse effects are not expected when used correctly.
  • Incorrect use, damaged cables, or use with incompatible mains voltages may increase the risk of electrical shock, overheating or fire.
  • Use of an incorrect or faulty power adapter may cause malfunction or permanent damage to the 9600 Plus Calibration Tester, potentially compromising thermometer calibration verification until the issue is resolved.

Storage Conditions

  • Store the power adapter kit in a clean, dry environment when not in use.
  • Avoid exposure to excessive heat, direct sunlight, moisture or corrosive substances.
  • Do not sharply bend, pinch or crush the cable during storage; loosely coil the cable to prevent kinking or internal conductor damage.
  • Keep out of reach of unauthorised personnel and store with other 9600 Plus Calibration Tester accessories or service parts as per local procedures.

Duration

Not applicable; this product is a power adapter accessory used continuously or as needed while operating the Welch Allyn 9600 Plus Calibration Tester.

Onset

Immediate, providing power to the 9600 Plus Calibration Tester as soon as it is correctly connected to mains and the device is switched on.