ABPM CardioPerfect Software
Welch Allyn
Medical diagnostic software – ambulatory blood pressure monitoringWelch Allyn CardioPerfect Workstation software module for ABPM devices
Certifications
- Supplied as part of, or as an accessory/upgrade to, Welch Allyn ABPM systems such as the ABPM 7100, which manufacturer documentation states fulfil requirements of the Medical Device Directive 93/42/EEC (MDD) and relevant RoHS directive and bear the CE mark as medical devices.
- Intended for professional use in clinical environments as part of a regulated ambulatory blood pressure monitoring system; no separate public listing of the software alone in medicines or substance databases has been identified.
- Described by medical equipment distributors as CardioPerfect software and updates, associated with medical device classification codes such as UNSPSC 42181700 (medical diagnostic equipment) and HPIS code 400_150_60_0 in some catalogues.
- Supplied as part of, or as an accessory/upgrade to, Welch Allyn ABPM systems such as the ABPM 7100, which manufacturer documentation states fulfil requirements of the Medical Device Directive 93/42/EEC (MDD) and relevant RoHS directive and bear the CE mark as medical devices.
- Intended for professional use in clinical environments as part of a regulated ambulatory blood pressure monitoring system; no separate public listing of the software alone in medicines or substance databases has been identified.
- Described by medical equipment distributors as CardioPerfect software and updates, associated with medical device classification codes such as UNSPSC 42181700 (medical diagnostic equipment) and HPIS code 400_150_60_0 in some catalogues.
Welch Allyn CardioPerfect Workstation software module for ABPM devices
Description
ABPM CardioPerfect Software is a Welch Allyn CardioPerfect Workstation software module supplied for use with the Welch Allyn ambulatory blood pressure monitor (ABPM) range, including devices such as the ABPM 6100 and ABPM 7100. It is used by healthcare professionals to communicate with the ABPM recorder, configure monitoring protocols, download recorded blood pressure data and manage that data within the CardioPerfect Workstation environment. The software enables analysis and presentation of ambulatory blood pressure measurements in various graphical and tabular formats and supports creation of detailed reports for clinical decision-making.
Bnefits
- Provides a dedicated CardioPerfect Workstation software module for Welch Allyn ambulatory blood pressure monitors, allowing compatible ABPM recorders to be configured and managed from a PC.
- Enables downloading and storage of 24-hour (or longer) ambulatory blood pressure recordings into the CardioPerfect Workstation patient database for review and long-term record keeping.
- Offers statistical summaries of ambulatory blood pressure measurements, including parameters such as systolic and diastolic blood pressure, mean arterial pressure, heart rate and related averages and extremes as described in CardioPerfect Workstation literature for ABPM.
- Displays ambulatory blood pressure data using graphical tools such as 24-hour blood pressure profiles and time-based trend graphs to support clinical interpretation of hypertension patterns.
- Supports generation of configurable, printable ambulatory blood pressure reports within the CardioPerfect Workstation environment to aid diagnostic assessment and documentation.
- Integrates ABPM data into the broader Welch Allyn CardioPerfect Workstation system, which is designed to manage data from multiple Welch Allyn cardiopulmonary devices in a single electronic record.
- Supplied as a software product with a Quick Start Guide, providing basic guidance for installation and initial configuration for the Welch Allyn ABPM range.
Indications
- Use by trained healthcare professionals to configure, download and analyse data from compatible Welch Allyn ambulatory blood pressure monitors (e.g. ABPM 6100 or ABPM 7100) within the CardioPerfect Workstation environment.
- Support of ambulatory blood pressure monitoring studies used in the diagnosis and management of hypertension and related cardiovascular risk, by providing tools to review and interpret ambulatory blood pressure data.
- Integration of ambulatory blood pressure results into a cardiopulmonary data management system (CardioPerfect Workstation) that can hold multiple test types in one patient record.
Composition
- PC-based CardioPerfect Workstation software module for ambulatory blood pressure monitoring (ABP module) supplied by Welch Allyn.
- Licensed software product associated with manufacturer part numbers such as ABP-SW for CardioPerfect software upgrades for ABPM 6100, and used with devices like the ABPM 7100 that connect to CardioPerfect Workstation.
- Functional components described in manufacturer literature include tools for device configuration, data acquisition from the ABPM recorder and subsequent storage and analysis of the recorded blood pressure data in the CardioPerfect Workstation database.
Formulation
- Software-only product (no consumable clinical components) forming the ABP module within the Welch Allyn CardioPerfect Workstation software suite.
- Designed to communicate with compatible Welch Allyn ABPM recorders via an appropriate PC interface cable and configured within the CardioPerfect Workstation settings under the ambulatory blood pressure section, as described in ABPM hardware manuals.
- Part of a modular cardiopulmonary software platform intended to handle data from multiple Welch Allyn diagnostic devices within a unified workstation application.
Packaging
- Listed by medical distributors as including the ABPM CardioPerfect software and a Quick Start Guide.
- Supplied as a software licence/product; physical contents (such as discs or printed guides) and exact packaging format are not fully detailed in publicly available retailer descriptions.
- No single-use clinical accessories are included; it is an accessory/software component for existing Welch Allyn ABPM hardware systems.
Usage
- Install the CardioPerfect Workstation software and the ABPM module on a compatible computer, following the installation instructions provided by Welch Allyn or in the Quick Start Guide supplied with the software.
- Connect the compatible Welch Allyn ABPM recorder to the PC using the approved PC interface cable and ensure that any required device drivers are installed, as described in the ABPM hardware manual.
- Open the CardioPerfect Workstation software, log in and configure the ambulatory blood pressure module for the connected ABPM device via the software settings (e.g. selecting the correct device and communication port as shown in ABPM 6100 and ABPM 7100 manuals).
- Use the software to set or adjust measurement protocols on the ABPM recorder as permitted by the specific device and software configuration, in line with local clinical procedures.
- After the monitoring period, reconnect the ABPM recorder and use the CardioPerfect Workstation software to download the recorded ambulatory blood pressure data into the patient record.
- Review the data using the available statistical and graphical views within CardioPerfect Workstation and generate reports as required for clinical assessment and documentation.
- Refer to the official CardioPerfect Workstation ABP module user manual and the ABPM device manuals for detailed, step-by-step operating instructions and safety information.
Contraindications
- Not publicly listed
- Use is restricted to qualified healthcare professionals trained in ambulatory blood pressure monitoring and in the use of Welch Allyn ABPM devices and CardioPerfect Workstation software, according to the applicable device and software manuals.
Adverse Effects
- Not publicly listed
Storage Conditions
- Not publicly listed
- As a software product, storage and handling recommendations typically relate to secure storage of installation media, licence keys and any printed documentation, and to maintaining the host computer environment in accordance with the manufacturer’s IT and operating system requirements as specified in the CardioPerfect Workstation documentation.
Duration
Not applicable (diagnostic software component; does not define a treatment course or duration)
Onset
Not applicable (diagnostic software; no pharmacological or therapeutic onset of action)
| Price | Link |
|---|---|
| £241.19 | https://www.medisave.co.uk/products/abpm-cardioperfect-software |













