OMRON RS7 Intelli IT Wrist Blood Pressure Monitor

OMRON RS7 Intelli IT Wrist Blood Pressure Monitor

OMRON

Diagnostics & Monitoring
  • CE marked medical device under the former Medical Device Directive 93/42/EEC / applicable EU medical device legislation.
  • Clinically investigated and validated according to ISO 81060 2 requirements for non Invasive sphygmomanometers.
  • Complies with European Standard EN1060 for non Invasive blood pressure monitoring devices.
  • Conforms to EN 60601 1 2:2015 Electromagnetic Compatibility (EMC) standard for medical electrical equipment.
  • Classified as an electronic sphygmomanometer (automatic wrist blood pressure monitor) with IP22 ingress protection rating.
Automatic Wrist Blood Pressure Monitor

Description

The OMRON RS7 Intelli IT (model HEM-6232T-E) is a clinically validated, fully automatic wrist blood pressure monitor with Bluetooth connectivity, designed for discreet and accurate monitoring at home or on the go. It uses OMRON Intellisense technology, a positioning sensor and a cuff wrap guide to help ensure correct placement at heart level and reliable results. The compact monitor fits wrist circumferences from 13.5 to 21.5 cm and features an irregular heartbeat detector, body movement detection, easy high blood pressure indicator, averaging function and memory for 2 users with up to 100 readings each. Measurements can be synced wirelessly to the OMRON connect app on a smartphone for tracking and sharing with healthcare professionals. The RS7 Intelli IT is supplied with the wrist cuff, batteries, storage case, blood pressure record card and setup instructions.

Bnefits

  • Clinically validated automatic wrist blood pressure monitor for adult home use.
  • Compact, lightweight device with a virtually silent pump for discreet measurements anywhere.
  • Wrist cuff fits 13.5–21.5 cm, suitable for a wide range of adult wrist sizes.
  • Intellisense technology automatically inflates the cuff to the optimal level for comfort and accurate readings.
  • Cuff Wrap Guide and advanced positioning sensor indicate correct cuff fit and wrist position at heart level.
  • Detects irregular heartbeats during measurement and displays a symbol when detected.
  • Body movement detection alerts the user if movement may have affected the reading.
  • Easy high blood pressure indicator helps users interpret elevated readings.
  • Memory for 2 users × 100 readings, enabling trend tracking for two individuals.
  • Averaging function to display the average of multiple readings for a more reliable indication.
  • Bluetooth Low Energy connectivity to sync measurements automatically with the OMRON connect app.
  • Storage case included for protection and convenient transport.
  • Designed and validated for use in people with obesity (obesity validation).

Indications

  • Non-invasive measurement of systolic and diastolic blood pressure and pulse rate at the wrist in adult patients.
  • Home and on-the-go monitoring of hypertension and blood pressure trends between medical consultations.
  • Monitoring the effectiveness of antihypertensive therapy as part of a clinician-directed care plan.
  • Screening and self-checking for elevated blood pressure in adults at cardiovascular risk, when used in accordance with medical advice.

Composition

  • Main unit: electronic automatic wrist blood pressure monitor with plastic housing, LCD digital display, internal electric pump, pressure sensor and control electronics.
  • Wrist cuff with integrated inflatable air bladder designed for wrist circumferences 13.5–21.5 cm.
  • Air system integrated into the cuff and main unit (no separate tube as in upper-arm models).
  • Two AAA 1.5 V alkaline batteries (power source).
  • Storage case for protection and transport.
  • Printed instruction manual, blood pressure record card and setup guide for OMRON connect.

Formulation

  • Non-invasive, oscillometric automatic wrist blood pressure and pulse monitor with Intellisense-controlled inflation, automatic rapid deflation, Bluetooth Low Energy transmission and digital display of measured values, incorporating cuff wrap guidance, positioning sensor, irregular heartbeat and body movement detection, averaging function and dual-user memory.

Packaging

  • Retail box containing: RS7 Intelli IT wrist blood pressure monitor, integrated wrist cuff (13.5–21.5 cm), 2 × AAA alkaline batteries, storage case, instruction manual, blood pressure record card and setup instructions for the OMRON connect app.
  • Model / reference: RS7 Intelli IT, HEM-6232T-E.
  • EAN code: 4015672111172.
  • Distributor reference example (France-Health): 7211117.

Usage

  • Install 2 new AAA alkaline batteries in the battery compartment, observing correct polarity.
  • Wrap the wrist cuff on the bare wrist (left wrist recommended) so that the display is on the inside of the wrist and the cuff edge is 1–2 cm from the palm; do not place over clothing.
  • Fasten the cuff snugly, ensuring there is no gap between cuff and skin and that it does not cover the protruding wrist bone.
  • Sit in a chair with back supported, feet flat on the floor and legs uncrossed. Rest for at least 5 minutes before measurement.
  • Place the elbow on a table so that the wrist is at heart level. Relax the hand and wrist; do not bend or clench the fist.
  • Turn on the monitor and, if using memory, select the correct user ID (1 or 2).
  • Ensure the positioning indicator shows that the wrist is at the correct height and the cuff wrap guide confirms proper fit.
  • Press the START/STOP button. Remain still and silent while the cuff inflates and deflates automatically.
  • Read the systolic and diastolic blood pressure and pulse rate on the display, along with any high blood pressure or irregular heartbeat symbol.
  • For average readings, use the averaging function as described in the instruction manual (e.g. multiple measurements taken within a short period).
  • To sync results with a smartphone, install the OMRON connect app, pair the monitor via Bluetooth following the setup guide, and allow automatic transfer of measurements.
  • After use, press START/STOP to turn off the monitor (or allow auto power-off), remove the cuff, and store the device and accessories in the storage case.
  • Take measurements at the same times each day (e.g. morning and evening) and record readings for review with a healthcare professional.

Contraindications

  • Do not use on infants, toddlers, children or persons who cannot express themselves; the device is intended for adults with wrist circumference 13.5–21.5 cm.
  • Do not use on a wrist with an intravenous line, arteriovenous (AV) shunt, or other intravascular access or where medical treatment is being applied.
  • Do not use on an injured, inflamed, severely scarred or postoperative wrist without medical advice.
  • Use only under medical supervision in patients with severe arrhythmias (e.g. atrial fibrillation), advanced arterial sclerosis, diabetes, pregnancy, or renal disease, as readings may be less reliable.
  • Do not use simultaneously with other medical electrical (ME) equipment or in environments with high-frequency surgical equipment, MRI or CT scanners, or in oxygen-rich/flammable atmospheres.
  • Not validated for use in pregnant patients; consultation with a healthcare professional is required for such use.

Adverse Effects

  • Temporary pressure sensation or discomfort at the wrist during cuff inflation.
  • Occasional minor redness, indentation or skin irritation at the cuff site, especially with frequent measurements or sensitive skin.
  • If pain, numbness, tingling, discoloration or unusual discomfort occurs in the hand or wrist during or after measurement, the cuff should be removed immediately and medical advice sought.

Storage Conditions

  • Store the monitor and cuff in the supplied storage case when not in use.
  • Keep in a dry place, away from direct sunlight, dust, moisture and corrosive vapours.
  • Observe storage/transport conditions: approximately −20 °C to +60 °C and 10–90% relative humidity (non-condensing), as per specifications.
  • Do not bend, twist or sharply crease the wrist cuff when storing the device.
  • Remove the batteries if the device will not be used for an extended period to prevent leakage.
  • Keep out of reach of infants, children and pets.

Duration

Used intermittently for individual blood pressure measurements and ongoing monitoring as advised by a healthcare professional; no fixed treatment duration for device use.

Onset

Immediate \u2014 each measurement cycle typically completes within seconds, with results displayed as soon as cuff deflation finishes.