Medical / Aesthetic Device
  • CE Marked medical device system (laser) for appropriate indications, subject to regional regulatory clearances.
  • Zimmer Cryo 6: CE Marked cold air skin cooling device for use in conjunction with dermatologic and aesthetic procedures.
  • Must be operated in accordance with applicable laser safety standards (e.g. IEC/EN laser safety classifications) and local medical device regulations.
Mixed-technology Alexandrite & Nd:YAG dermatologic laser with external cold air skin cooling system

Description

The Quanta Duetto MT EVO is a high-end mixed-technology dermatologic laser platform designed for hair removal, vascular treatments and skin rejuvenation. It combines Alexandrite 755 nm and Nd:YAG 1064 nm laser sources that can be delivered as single, sequential or simultaneous (mixed) emissions. This flexibility, together with large spot sizes, a wide range of pulse durations and high repetition rates, makes the system suitable for all skin phototypes and a wide spectrum of indications including permanent hair reduction, vascular lesions and non-ablative skin rejuvenation. When paired with the Zimmer Cryo 6 cold air system, the device offers powerful epidermal protection and analgesia by delivering continuous streams of cold air to the treatment area before, during or after laser exposure, enhancing patient comfort and safety while minimizing the risk of thermal injury.

Bnefits

  • Dual-wavelength mixed technology: Alexandrite 755 nm and Nd:YAG 1064 nm, usable in single, sequential or simultaneous mixed emission modes.
  • Treats a broad range of indications including permanent hair reduction, vascular lesions and skin rejuvenation with one platform.
  • Suitable for all skin types and tones (I–VI) and a wide range of hair types by tailoring wavelength, fluence, pulse width and emission mode.
  • Large spot sizes and fast repetition rates enable rapid treatment of large body areas.
  • Programmable fluence and pulse duration with adjustable sequences improve efficacy while optimizing patient safety.
  • Upgradeable with TWAIN IPL and other optional handpieces to expand treatment capabilities.
  • Zimmer Cryo 6 provides powerful, contact-free cold air skin cooling (air as low as approximately −30 °C at the nozzle) for significant pain reduction and epidermal protection.
  • Cold air cooling can be applied before, during and after laser pulses without interfering with the laser beam, improving comfort and reducing risk of burns.
  • Zimmer Cryo 6 uses filtered room air and requires no consumables, allowing continuous operation with minimal running costs.

Indications

  • Permanent hair reduction/removal on face and body for all skin phototypes (I–VI).
  • Treatment of benign vascular lesions such as telangiectasia, leg veins and other superficial vascular conditions (Nd:YAG 1064 nm).
  • Non-ablative skin rejuvenation and tightening using Nd:YAG parameters.
  • Treatment of certain benign pigmented lesions (depending on clinical protocol and configuration).
  • Reduction of pseudo-folliculitis barbae and prevention of ingrown hairs.
  • Zimmer Cryo 6: epidermal cooling and pain relief during dermatologic and aesthetic laser treatments, injections and other procedures.

Composition

  • Solid-state Alexandrite laser source (755 nm).
  • Solid-state Nd:YAG laser source (1064 nm).
  • Internal optics and beam delivery system with variable spot-size handpieces (e.g. 2–5 mm, 10 mm, 14 mm, 18 mm – exact configuration depends on package).
  • Integrated control console with touchscreen interface and software for mixed-technology emission control.
  • Footswitch, operator and patient safety eyewear and other standard laser safety accessories (depending on configuration).
  • Zimmer Cryo 6 cold air unit including compressor, refrigeration system, control electronics and 1.8 m treatment hose with optional focusing tips.

Formulation

Not publicly listed

Packaging

  • Main Duetto MT EVO laser console with dual-wavelength laser sources.
  • One or more variable spot-size treatment handpieces with fiber delivery and storage case (exact number and sizes depend on system configuration).
  • Integrated or external skin cooling interface/adapter for use with cold air cooling.
  • Zimmer Cryo 6 unit with glass/Plexiglas top, 1.8 m cooling hose and control panel (supplied when purchased as a combined system).
  • Standard accessories typically include: foot pedal, operator manual set, operator goggles and patient goggles, system cover and power cables (contents may vary by distributor).

Usage

  • Only trained and appropriately licensed medical or aesthetic professionals should operate the Duetto MT EVO and Zimmer Cryo 6 systems.
  • Perform a thorough medical history, skin and hair assessment and obtain informed consent prior to treatment.
  • Select the appropriate wavelength (755 nm, 1064 nm or mixed), fluence, pulse duration, spot size and emission mode based on indication, skin type and hair characteristics according to the manufacturer’s guidelines and clinical judgment.
  • Prepare the treatment area by cleansing the skin and shaving hair if performing hair removal; avoid active infections, open wounds or recent sunburn in the target area.
  • Provide certified protective eyewear to the patient and all personnel in the treatment room.
  • Position the Zimmer Cryo 6 nozzle 5–20 cm from the treatment area and select the desired airflow level; start cooling shortly before initiating laser pulses.
  • Deliver laser pulses in a systematic pattern, ensuring adequate overlap as recommended while monitoring skin response; adjust parameters if necessary for safety and comfort.
  • Maintain continuous or intermittent cold air flow from the Cryo 6 before, during and after laser application to minimize discomfort and reduce risk of epidermal injury.
  • After treatment, continue cooling for a short period if needed, then apply appropriate post-treatment care (e.g. soothing topical products) and advise strict photoprotection.
  • Schedule follow-up sessions depending on the indication (e.g. hair removal typically requires multiple sessions spaced several weeks apart).
  • Perform regular maintenance, safety checks and calibration as recommended by the manufacturer or authorized service provider; keep air filters of the Cryo 6 clean and empty the condensation collector at the recommended intervals.

Contraindications

  • Active infections, open wounds or inflammatory skin diseases in the intended treatment area.
  • Recent significant sun exposure, sunburn or use of tanning beds in the treatment area without adequate recovery time.
  • History of keloid formation or abnormal scarring, or severely impaired wound healing.
  • Known photosensitivity disorders or use of strong photosensitizing medications, unless carefully assessed and cleared by a physician.
  • Pregnancy as a general precaution, unless local regulations and clinical judgment explicitly allow treatment.
  • Uncontrolled systemic disease or conditions that the treating physician considers unsafe for laser procedures.
  • Patients unable or unwilling to comply with eye protection, treatment instructions or post-treatment sun avoidance.
  • History of hypersensitivity to extreme cold (for use of Zimmer Cryo 6), such as cold urticaria or cryoglobulinemia.

Adverse Effects

  • Transient erythema (redness), edema and mild discomfort or burning sensation in the treated area.
  • Temporary darkening or lightening of the skin (post-inflammatory hyper- or hypopigmentation), particularly if sun exposure is not adequately avoided.
  • Crusting, blistering or superficial burns if parameters or technique are inappropriate or if there is inadequate epidermal protection.
  • Rare risk of scarring or textural changes with improper use or in highly susceptible patients.
  • With Zimmer Cryo 6, excessive cooling or prolonged exposure at very close distances may rarely cause cold-related skin irritation or, in extreme cases, frostbite if used contrary to guidelines.

Storage Conditions

  • Install and store the Duetto MT EVO and Zimmer Cryo 6 systems in a clean, dry, well-ventilated clinical environment.
  • Keep units on stable, level surfaces with sufficient clearance around ventilation inlets and outlets.
  • Avoid exposure to excessive dust, moisture, corrosive vapors and temperature extremes outside the manufacturer’s specified operating and storage ranges.
  • Ensure power supply and grounding meet the manufacturer’s electrical specifications.
  • Turn off and unplug devices before long periods of non-use or when performing certain maintenance procedures.

Duration

Individual session duration varies by indication and treatment area size; small areas may take only a few minutes, while large body areas can take 20\u201360 minutes. Hair removal and many vascular or rejuvenation indications typically require multiple sessions (commonly 4\u20138 or more) spaced several weeks apart for optimal results.

Onset

Initial clinical improvements, such as hair shedding or vessel clearance, are often visible within days to weeks after treatment, with progressive results over the course of repeated sessions. Pain reduction and epidermal protection from Zimmer Cryo 6 cooling are immediate during use.