Rack, Back Up, For SRS/SRT, 10 Tubes, 729073, Graduated
Greiner Bio-One
Laboratory accessoryESR tube rack / backup rack for manual ESR system
Certifications
- Manufactured by Greiner Bio One GmbH under an EN ISO 13485 Certified quality management system for medical devices.
- Part of the VACUETTE preanalytics product line, which is produced under ISO 9001 and ISO 13485 quality standards.
- Supported by a Declaration of Conformity for the ESR Rack with graduation (item 836077) issued by Greiner Bio One, indicating conformity with relevant European medical device and IVD requirements as an accessory for ESR testing.
- Manufactured by Greiner Bio One GmbH under an EN ISO 13485 Certified quality management system for medical devices.
- Part of the VACUETTE preanalytics product line, which is produced under ISO 9001 and ISO 13485 quality standards.
- Supported by a Declaration of Conformity for the ESR Rack with graduation (item 836077) issued by Greiner Bio One, indicating conformity with relevant European medical device and IVD requirements as an accessory for ESR testing.
ESR tube rack / backup rack for manual ESR system
Description
The Greiner Bio-One Rack, Back-Up, for SRS/SRT, 10 Tubes, 729073, Graduated (item 836077) is a non-sterile ESR tube rack designed as a back-up or manual stand for VACUETTE® ESR tubes, specifically types 729073 and 729093. The rack provides 10 positions for ESR tubes and features an integral graduation scale that allows visual reading of erythrocyte sedimentation rate (ESR) values when used as part of the VACUETTE manual ESR system. It is intended for use in clinical laboratories and other diagnostic environments as an accessory for sedimentation rate testing, particularly when used with Greiner Bio-One SRS/SRT ESR systems or as a back-up to automated measurement.
Bnefits
- Provides 10 clearly arranged positions for VACUETTE ESR tubes (729073 / 729093) for manual or back-up ESR measurements.
- Integrated graduation scale enables direct visual reading of erythrocyte sedimentation rates.
- Designed as a back-up rack for SRS/SRT ESR systems, allowing continued testing if automated systems are unavailable.
- Non-sterile, reusable laboratory accessory suitable for routine use in preanalytics and haematology laboratories.
- Compatible with VACUETTE ESR tubes, integrating seamlessly into existing Greiner Bio-One preanalytics workflows.
- Robust plastic construction designed for stability on the bench to help minimize risk of tube tipping or spillage.
- Packaged as single racks with carton quantities that support laboratory stock management (box of 1, carton of 8).
Indications
- Accessory for manual or back-up erythrocyte sedimentation rate (ESR) testing using VACUETTE ESR tubes.
- Designed for use with Greiner Bio-One ESR tubes 729073 / 729093 in conjunction with the VACUETTE manual ESR system.
- Use in clinical laboratories, hospital laboratories and diagnostic facilities performing ESR testing in preanalytics.
- Serves as a back-up rack for SRS/SRT ESR systems where ESR values are read on a graduated rack when needed.
Composition
- Material: high-quality plastic construction (typical of Greiner Bio-One laboratory racks; exact polymer not specified in publicly available product descriptions).
- Non-sterile laboratory-grade accessory, intended for repeated use as part of ESR preanalytics.
- Printed or moulded graduation scale along the side of the rack for reading sedimentation height.
Formulation
- Device type: ESR rack with graduation / back-up rack for SRS/SRT systems.
- Item number (Greiner Bio-One): 836077.
- Tube compatibility: VACUETTE ESR tubes 729073 / 729093.
- Number of tube positions: 10.
- Sterility: non-sterile.
- Intended use: manual or back-up ESR measurements as part of the VACUETTE ESR system.
- Packaging unit (outer carton): 8 racks per case.
- Quantity per inner pack: 1 rack.
- Approximate carton dimensions: 294 × 193 × 296 mm.
- Approximate packaging weight per case: 3.55 kg.
Packaging
- Supplied as a single ESR rack (item 836077) per inner pack.
- Outer shipping carton typically contains 8 individual racks (packing unit 8, quantity per inner pack 1).
- Non-sterile accessory supplied without tubes; ESR tubes 729073 / 729093 are ordered separately.
- Labelling identifies the rack as an ESR rack with graduation for VACUETTE ESR tubes (729073 / 729093), non-sterile, with Greiner Bio-One branding and item number.
Usage
- Place the ESR rack on a stable, level laboratory bench close to the area where VACUETTE ESR tubes are handled.
- Insert filled VACUETTE ESR tubes (729073 / 729093) vertically into the 10 rack positions, ensuring that tubes are fully seated and upright.
- Align the bottom of the erythrocyte column with the zero point of the printed graduation scale, according to the instructions for the VACUETTE ESR system or local laboratory protocol.
- After the prescribed sedimentation period, read the sedimentation height on the graduation scale next to each tube to determine ESR values.
- Record results according to laboratory procedures and remove tubes from the rack once readings are completed.
- Clean the rack regularly with an appropriate laboratory surface disinfectant or mild detergent solution if contaminated with blood or other biological material, following local biosafety protocols.
- Do not autoclave or expose to high temperatures unless confirmed compatible with the rack material; follow any additional handling instructions provided in Greiner Bio-One preanalytics documentation.
- Inspect the rack periodically for cracks, deformation, or damage to the graduation markings; replace if damage could affect stability or readability.
Contraindications
- Not intended for direct patient contact or use as an implantable or invasive medical device.
- Do not use with tubes other than compatible VACUETTE ESR tubes (729073 / 729093) where accurate positioning and reading of the graduation scale may not be ensured.
- Do not use if the rack is visibly damaged, cracked, deformed, or if graduation markings are illegible, as this may compromise ESR readings.
- Not suitable for use in sterilized environments that prohibit non-sterile plastic accessories unless local protocols explicitly allow it after appropriate decontamination.
Adverse Effects
- No direct patient adverse effects are expected when used as intended, as the rack is a non-contact laboratory accessory.
- Improper use (e.g., unstable placement, damaged rack) may increase risk of tube tipping, breakage, or spillage of blood samples, which can pose biosafety risks to staff.
- Incorrect positioning of tubes or misreading of the graduation scale could contribute to erroneous ESR results; laboratories should ensure staff are trained in correct use.
Storage Conditions
- Store at room temperature in a dry, clean laboratory environment.
- Keep away from direct sunlight and excessive heat sources to prevent warping or fading of graduation markings.
- Avoid contact with strong solvents or aggressive chemicals that could damage plastic surfaces or printed graduations.
- Store the rack where it is protected from mechanical damage (e.g., crushing or bending) when not in use.
Duration
Not applicable \u2013 this product is a laboratory accessory for ESR testing and is not used directly for patient treatment.
Onset
Not applicable \u2013 as a non-clinical accessory, it provides immediate functional use during ESR measurement procedures.