S Monovette® Serum Gel CAT, 7.5 ml (92 x 15 mm) Box of 50
S-Monovette® (Sarstedt)
Medical device / In-vitro diagnostic (IVD)Venous blood collection tube \u2014 serum gel with clot activator
Certifications
- CE certified (manufacturer self Declaration) for in Vitro diagnostic use
- Sterile; sterilisation by electron irradiation
- Packaged and labelled to satisfy IATA and ADR transport requirements
- CE certified (manufacturer self Declaration) for in Vitro diagnostic use
- Sterile; sterilisation by electron irradiation
- Packaged and labelled to satisfy IATA and ADR transport requirements
Venous blood collection tube \u2014 serum gel with clot activator
Description
S-Monovette® Serum Gel CAT 7.5 ml is a sterile venous blood collection tube (92 x 15 mm) containing a clotting activator and a separating gel. The tube uses a membrane screw cap (brown/EU-ISO colour coding) and is supplied with a paper label. It is intended for serum collection and subsequent centrifugation for clinical chemistry testing. Sterilised by electron irradiation and supplied batched in packs of 50.
Bnefits
- Clot activator with separating gel forms a stable serum/plasma barrier after centrifugation for improved sample quality
- Membrane screw cap provides a liquid-tight closure and compatibility with S-Monovette handling systems
- Sterile, electron-irradiated and IATA/ADR compliant for transport
- CE certified (manufacturer self-declaration) for intended IVD use
Indications
- Collection of venous blood for serum preparation and subsequent laboratory analysis (clinical chemistry, serology) following clotting and centrifugation
Composition
- Tube material: Polypropylene (PP)
- Cap/closure: High-density polyethylene (HD-PE) screw cap with membrane
- Membrane material: Rubber (membrane screw cap)
- Additives: Clotting activator (silicate) and separating gel (proprietary gel formulation)
- Label: Paper label with brown print (EU/ISO colour coding for serum tubes)
Formulation
- Sterile, single-use blood collection tube with clot activator and separating gel; membrane screw cap closure; fill mark / graduation indicated
Packaging
- Pack size: 50 tubes per inner box (sterile, batched)
- Manufacturer order number: 01.1602.001 (refer to carton labelling for lot, expiry and IFU)
Usage
- Collect venous blood into the tube using appropriate S-Monovette collection technique or compatible systems
- Allow blood to clot (typical clotting time ~20–30 minutes with clot activator), then centrifuge at recommended conditions (2500 x g, 20°C for 10 minutes) to obtain separated serum
- Follow local laboratory procedures and the Sarstedt Instructions for Use (IFU) for handling, storage, transport and disposal
Contraindications
- Not to be used if sterility of package is compromised or packaging is damaged
- Not intended for collection of samples requiring anticoagulated whole blood (use appropriate anticoagulant tube instead)
Adverse Effects
- Device-related risks are typical of venepuncture and include haemolysis if improper technique is used; follow standard venepuncture and sample handling precautions
- Not reported as causing adverse systemic effects — adverse events are associated with blood collection procedure rather than the tube itself
Storage Conditions
- Store in original packaging in a cool, dry place away from direct sunlight
- Refer to product carton and IFU for storage temperature range and shelf-life information
Duration
Not applicable (single-use collection device used per venepuncture/sample)
Onset