Astralite eLite Minor Surgical Mounted Light
Brandon Medical
Medical examination and minor surgical lightingWall-mounted HD-LED minor surgical light
Certifications
- CE Marked medical device compliant with the Medical Devices Directive 93/42/EEC (and amendments 2007/47/EC) as indicated in technical literature
- Designed and tested to EN 60601 1 (medical electrical equipment – general safety) and EN 60601 2 41 (particular requirements for surgical luminaires and luminaires for diagnosis)
- LED rated life >50,000 hours and electrical performance tested to relevant IEC/EN standards for lighting
- Incorporates antimicrobial additives in plastics and paints to support infection prevention and control in clinical environments
- CE Marked medical device compliant with the Medical Devices Directive 93/42/EEC (and amendments 2007/47/EC) as indicated in technical literature
- Designed and tested to EN 60601 1 (medical electrical equipment – general safety) and EN 60601 2 41 (particular requirements for surgical luminaires and luminaires for diagnosis)
- LED rated life >50,000 hours and electrical performance tested to relevant IEC/EN standards for lighting
- Incorporates antimicrobial additives in plastics and paints to support infection prevention and control in clinical environments
Wall-mounted HD-LED minor surgical light
Description
The Astralite eLite Minor Surgical Wall Mounted Light is a high-performance HD-LED minor surgical and examination lamp from Brandon Medical, designed for use in operating rooms, treatment rooms and clinics. Using patented solid-state focusing technology, it combines LEDs with different beam shapes superimposed to create an extremely effective and reliable focus system with a wide adjustment range. The eLite 10 wall-mounted model (ALE10WJ) delivers high-intensity cold light up to 100,000 lux at 1 m, with variable light intensity (8 steps), adjustable colour temperature from 3,500 K to 5,000 K, and exceptional colour rendering (Ra and R9 > 95) for accurate tissue differentiation. A large 250 mm illuminated field and 180 mm beam at 1 m provide excellent coverage, while the HD-LED technology produces natural white light with minimal heat. The lamp head incorporates antimicrobial additives (e.g., Polygiene-style/biomaster technology) and smooth, sealed surfaces to help reduce infection risk, making it ideal for minor procedures, suturing, A&E, dermatology, gynaecology and general examination.
Bnefits
- High-intensity cold light delivering up to approximately 100,000 lux at 1 metre for demanding minor surgical procedures
- HD-LED technology with near-perfect colour rendition (Ra > 95, R9 > 95) for accurate tissue and blood colour discrimination
- Patented solid state focusing using LEDs with different beam shapes superimposed for an effective, reliable focusing system and wide adjustment range
- "Auto On" feature turns the light on as soon as any control is touched, simplifying operation during procedures
- Adjustable colour temperature (approximately 3,500–5,000 K) and 8-step intensity control to optimise contrast for different tissues and procedures
- Large 250 mm illuminated field and 180 mm beam size at 1 m for excellent coverage and easy targeting of the wound area
- Excellent shadow control by spreading LEDs across the entire light head, helping to under-light obstructions such as the surgeon’s hands
- Long LED life (>50,000 hours) with no bulb changes required, providing low lifetime cost and high reliability
- Low power consumption (typically <32 VA) making the system economical and environmentally friendly
- Antimicrobial lamp head surfaces incorporating additives to inhibit bacteria, viruses and yeasts, with smooth, sealed design for easy cleaning and infection control
- Wide movement range with multiple rotational axes, allowing the light head to be positioned all around the couch and from almost any angle
Indications
- Illumination for minor surgical procedures in theatres, treatment rooms and outpatient environments
- General minor operations and suturing in A&E / emergency departments
- Dermatology and minor skin surgery (e.g., excisions, biopsies, lesion removal)
- Gynaecological procedures, colposcopy and minor interventions
- Procedures in GP surgeries, ambulatory care centres and minor ops suites where high-quality focused lighting is required
- General examination lighting in medical, dental and aesthetic clinics where high-intensity, colour-accurate light is beneficial
Composition
- HD-LED lamp head with multiple high-efficiency white LEDs distributed across the lighting surface
- Integrated optics with patented solid-state focusing system using LEDs of different beam shapes for adjustable focus
- Plastic lamp head components with built-in antimicrobial additives (e.g., silver ion / Polygiene-type technology) in moulded parts and antimicrobial-treated paint
- Sealed lamp head construction to prevent ingress of dirt and liquids and to facilitate cleaning
- Articulated arm system providing 5 rotations for wide positioning capability
- Wall-mount bracket and support arm designed for fixed installation on clinical walls
- Electronic driver and control circuitry integrated into the system for intensity and colour temperature control
- User interface with wipe-clean controls on or near the lamp head/arm
Formulation
- Non-invasive, mains-powered, solid-state LED minor surgical and examination luminaire
- Provides cool, shadow-controlled illumination with adjustable colour temperature and intensity
- Designed as a permanently wall-mounted fitting with articulated arm and HD-LED lamp head
- Incorporates antimicrobial materials and coatings in lamp head plastics and paint finishes
- Meets medical electrical and lighting standards for minor surgical and examination use
Packaging
- Astralite eLite 10 wall-mounted lamp head with HD-LED module
- Articulated suspension arm suitable for wall mounting
- Wall mounting bracket and fixings (type may vary by distributor and installation kit)
- Integrated or separate control panel (depending on configuration)
- User manual / installation guide and technical documentation
- Supplied as a single complete wall-mounted lighting system; installation by qualified personnel required
Usage
- Installation must be carried out by suitably qualified electrical / medical equipment installers, following Brandon Medical’s installation manual and local electrical regulations.
- Securely mount the wall bracket to a suitable load-bearing wall structure and attach the articulated arm and lamp head as directed by the manufacturer.
- Connect the unit to a 100–240 V AC, 50/60 Hz mains supply via an appropriate fused spur or outlet, ensuring correct earthing and isolation in accordance with EN 60601-1 and local standards.
- After installation, verify all safety functions, movement ranges and light output according to the commissioning procedure before clinical use.
- During use, position the arm and lamp head over the operative or examination field using the ergonomic handle, taking advantage of the 5 rotations to achieve the desired angle and distance.
- Switch on or adjust the light by touching the wipe-clean control panel; use the Auto On feature, intensity control (8 steps) and colour temperature adjustment (3,500–5,000 K) to suit the procedure and tissue contrast required.
- Focus and field size can be adjusted by twisting or manipulating the handle (solid-state focusing) to increase or decrease the illuminated area and intensity at the surgical site.
- After procedures, wipe the lamp head, handle and arm surfaces with approved disinfectant wipes or cleaning solutions compatible with the materials, following infection control protocols and manufacturer guidance.
- Do not cover ventilation areas or modify the lamp head; ensure that the light is turned off when not in use and that routine visual checks and periodic servicing are carried out as per Brandon Medical’s recommendations.
- Only trained clinical staff should operate the light; any maintenance beyond cleaning and basic checks must be performed by authorised service personnel.
Contraindications
- Not suitable for use in environments with flammable anaesthetic mixtures or explosive atmospheres unless specifically certified for such use.
- Should not be used if the lamp head, arm, wall bracket or electrical connections are visibly damaged, loose or malfunctioning.
- Not intended for outdoor use or in locations with excessive moisture, corrosive fumes or extreme temperatures beyond the specified operating range.
- Use is contraindicated without appropriate routine electrical safety testing (e.g., in facilities that cannot perform periodic medical equipment checks).
- Do not use in direct contact with patients or sterile fields; it is an overhead lighting device only.
Adverse Effects
- Potential for temporary glare or visual discomfort if the light intensity is set too high or directed into the eyes of staff or patients.
- If incorrectly positioned or inadequately adjusted, shadows may interfere with visibility, although HD-LED design minimises this risk.
- Improper cleaning with harsh chemicals not approved by the manufacturer may damage plastics, coatings or antimicrobial properties.
- Risk of mechanical injury if the arm or lamp head is not securely mounted and maintained, or if used as a support to lean on (contraindicated by manufacturer).
Storage Conditions
- Designed for permanent installation in a clinical environment; when not in use, keep the lamp in its parked position away from doors or high-traffic areas.
- Operate and store in a clean, dry indoor environment within the temperature and humidity ranges specified by Brandon Medical (typically normal room conditions).
- Protect from excessive dust, corrosive vapours and direct water jets or splashes; the lamp head is sealed but not intended for hose-down cleaning.
- During long periods of non-use (e.g., room refurbishment), ensure the power supply is safely isolated and the unit is protected from accidental impact.
- Do not store or transport the lamp by the head or arm alone; support the structure adequately to avoid mechanical stress.
Duration
The light is used for the duration of minor surgical or examination procedures as required. LED lifetime is rated at greater than 50,000 hours, equating to many years of typical clinical use without lamp replacement.
Onset
Illumination is effectively instantaneous when the unit is switched on or when the Auto On control is touched, providing full light output immediately with no warm-up time.