Bariatric 2 Section Plinth

Bariatric 2 Section Plinth

Plinth Medical

Medical furniture
  • UK designed and manufactured medical couch by Plinth Medical Ltd., supplied through regulated medical distributors.
  • Manufactured under medical furniture quality systems consistent with UK healthcare furniture requirements.
  • Upholstery specified as hardwearing anti Microbial vinyl suitable for healthcare environments and compatible with standard infection Control cleaning protocols.
Electric bariatric 2-section treatment couch

Description

The Bariatric 2 Section Plinth (Plinth Medical Model 50E) is a heavy-duty electric treatment couch designed to safely lift and position large and very heavy patients. UK manufactured, it features electric operation of both height and backrest, a wide treatment surface and a safe working load and lifting capacity of 320 kg. The couch is upholstered in hardwearing anti-microbial vinyl over comfort foam and is supplied with a breathing hole as standard. Retractable castors and 140 mm hoist clearance enable easy movement and hoist access, while the robust frame is backed by a lifetime frame and 5-year parts guarantee and an average service life of around 16 years. Optional accessories such as arms, divided legs and cotsides can transform the unit into a truly multi-purpose bariatric couch.

Bnefits

  • Heavy-duty bariatric couch designed to safely lift and position very heavy patients (safe working load and lift capacity 320 kg).
  • Electric operation of height and backrest allows effortless push-button adjustment, improving ergonomics and reducing clinician strain.
  • Wide treatment surface provides stable, comfortable support for large and bariatric patients.
  • Hardwearing anti-microbial vinyl upholstery supports infection control and is easy to wipe clean.
  • Comfort foam provides a supportive yet comfortable surface, with optional upgrades to deeper, pressure-relieving foam and multi-stretch vinyl.
  • Retractable castors and 140 mm hoist clearance facilitate easy movement and compatibility with mobile hoists.
  • Motorised backrest allows precise patient positioning for examination and treatment.
  • Breathing hole and plug are supplied as standard to support prone treatments.
  • UK designed and manufactured with a lifetime frame guarantee, 5-year parts guarantee and an average lifespan of around 16 years, offering low running costs and long-term value.
  • Can be fitted with arms, divided legs, cotsides and other accessories to create a versatile multi-purpose couch for different departments.

Indications

  • Examination and treatment of bariatric and heavy patients in hospital, clinic, physiotherapy, rehabilitation and outpatient settings.
  • Use in departments where safe lifting and positioning of large or very heavy patients is required (e.g. physiotherapy, obesity services, general practice, community hospitals).
  • Situations where electric height and backrest adjustment are needed to optimise clinician ergonomics and patient comfort.
  • General treatment couch applications requiring a higher safe working load than standard couches.

Composition

  • Heavy-duty steel couch frame with welded construction and powder-coated finish.
  • High-density comfort foam on top sections, with optional deeper/pressure-relieving foam upgrade.
  • Hardwearing anti-microbial, fire-retardant vinyl upholstery (multiple healthcare colour options).
  • Electric actuators (e.g. Linak or equivalent) for height and backrest operation.
  • Retractable twin-wheel castors for mobility and positioning.
  • Plastic and rubber components for trims, feet and cable management.
  • Integrated breathing hole and removable plug in head section.

Formulation

  • Two-section electric bariatric couch with separate backrest and main section.
  • Electric height adjustment and motorised backrest controlled via handset or footswitch (depending on configuration).
  • Safe working load and lift capacity: 320 kg.
  • Hoist clearance: approximately 140 mm beneath frame.
  • Retractable heavy-duty castor base with adjustable foot for uneven floors.
  • Standard features: UK manufactured frame, lifetime frame & 5-year parts guarantee, 16-year average lifespan, comfort foam, anti-microbial vinyl, breathing hole.
  • Optional accessories: CPR motor back, battery back-up, folding cotsides, paper roll holder, double foam/pressure-relief upgrade, wide top variants.

Packaging

  • Supplied as a single fully assembled or partially assembled couch unit (depending on delivery method), typically delivered direct from manufacturer or distributor.
  • Heavily protected with transit packaging, corner protectors and wrapping suitable for large medical furniture.
  • Custom upholstery colour and accessory options specified at order; order is built to configuration and delivered on a direct-order basis.
  • Delivery requirements (e.g. access via side streets, narrow hallways or stairwells) must be communicated in advance for appropriate arrangements.

Usage

  • Install and commission the couch according to the manufacturer’s instructions, ensuring adequate floor strength and space for safe operation and hoist access.
  • Connect the power supply as specified and check functionality of height and backrest actuators before clinical use.
  • Adjust couch height using the electric controls to a safe working level for clinicians, minimising bending and manual handling strain.
  • Use the motorised backrest to position the patient appropriately for examination or treatment (supine, semi-recumbent, sitting or prone with breathing hole).
  • Apply and adjust accessories such as arms, cotsides or divided legs if fitted, ensuring they are securely locked before use.
  • Ensure retractable castors are set so that the couch is stable before the patient mounts the couch; engage castors for moving and disengage for treatment.
  • Observe the maximum safe working load of 320 kg and do not exceed this limit.
  • Clean the vinyl upholstery and frame between patients using suitable healthcare-approved cleaning agents compatible with anti-microbial vinyl; avoid harsh solvents or abrasive cleaners.
  • Periodically inspect the couch for signs of wear, damage to upholstery, loose fixings, or actuator issues and arrange servicing or repair according to the manufacturer’s maintenance schedule.
  • In the event of power failure, follow local procedures for safely lowering or repositioning the couch using any back-up features supplied (e.g. optional battery back-up if fitted).

Contraindications

  • Use with patients whose weight exceeds the stated safe working load and lift capacity of 320 kg.
  • Use in environments where the floor cannot safely support the combined weight of the couch and maximum patient load.
  • Use with damaged or heavily worn upholstery, frame or actuators that may compromise patient or clinician safety.
  • Use in explosive or highly flammable atmospheres or where the electrical classification requirements exceed the couch’s ratings.
  • Improper use as a lifting platform for equipment or as a step or seat for multiple individuals.

Adverse Effects

  • Potential risk of patient or staff injury if the couch is used beyond its safe working load or if brakes/castors are not correctly set before mounting or dismounting.
  • Risk of entrapment or pinch injury around moving parts (e.g. during height or backrest adjustment) if used without due care.
  • Possible discomfort or pressure issues for patients if used for very prolonged periods without appropriate pressure-relieving accessories.
  • Electrical hazard risk if the power cable or actuators are damaged and not inspected or serviced as recommended.

Storage Conditions

  • Designed for continuous use in clinical areas; when not in use, leave in a safe parked position with castors locked and height lowered if appropriate.
  • Operate and store in a dry indoor environment away from excessive moisture and extreme temperatures.
  • Avoid prolonged, direct exposure to strong sunlight on upholstery to reduce fading and material degradation.
  • Ensure power cable is routed to avoid trip hazards and is not crushed under wheels or furniture.
  • If the couch is taken out of service for storage, disconnect from mains power, cover to protect from dust, and store in a dry, secure area.

Duration

Onset

Browse more Medical furniture

Top Treatments