Daray 100W Halogen Bulb Capsule   Pack of 3

Daray 100W Halogen Bulb Capsule Pack of 3

Daray

Medical lighting accessories
  • Supplied as part of Daray’s medical lighting accessory range; Daray operates documented quality assurance processes for its healthcare lighting products.
  • Intended for use within Daray luminaires that are designed and certified to relevant electrical safety and medical lighting standards; the bulb itself should be installed and used in accordance with these certified systems.
  • Distributed in the UK by Medisave UK Ltd, which holds an MHRA Wholesale Distribution Authorisation (WDA) and operates ISO 9001 quality and ISO 14001 environmental management systems.
Replacement halogen capsule bulbs for surgical/examination lights

Description

The Daray 100W Halogen Bulb Capsule - Pack of 3 is a set of three replacement 100-watt halogen capsule bulbs designed for use with the Daray Illumin8 lighting range. Supplied as an OEM accessory from Daray, the capsules are specified as compatible with selected Illumin8 halogen models, including SL200HA, SL200HAMINI, SL250W, SL250C and SL250C/250C. These bulbs provide a bright, focused halogen light output suitable for examination and minor procedure lighting applications. Intended as a direct replacement for the original capsules supplied with Daray halogen lights, the pack-of-three format ensures convenient stockholding for clinical environments that rely on continuous availability of their Illumin8 lighting systems.

Bnefits

  • Genuine Daray replacement 100W halogen capsule bulbs for the Illumin8 lighting range, ensuring compatibility and reliable performance.
  • Supplied as a pack of three bulbs, providing convenient spares for busy clinical environments and minimising downtime.
  • Designed specifically for use with Daray Illumin8 halogen models (SL200HA, SL200HAMINI, SL250W, SL250C, SL250C/250C).
  • Maintains the original light quality and colour characteristics of the compatible Daray halogen examination and surgical lights.
  • OEM accessory from the original lighting manufacturer, supporting consistent performance and longevity when installed correctly.
  • Pack-of-three format is cost-effective and practical for maintenance schedules and preventative replacement programmes.

Indications

  • Replacement of exhausted or failed 100W halogen capsule bulbs in Daray Illumin8 halogen lighting systems.
  • Use in compatible Daray models: SL200HA, SL200HAMINI, SL250W, SL250C and SL250C/250C (as specified by Daray and distributors).
  • Maintaining the illumination performance of examination and minor procedure lights in clinics, theatres, treatment rooms and dental/veterinary surgery environments where these specific Daray models are installed.

Composition

  • Set of three 100-watt halogen capsule bulbs designed for medical lighting applications.
  • Halogen capsule lamps suitable for Daray Illumin8 halogen heads (e.g. SL200 and SL250 series) as specified by the manufacturer.
  • Electrical characteristics (e.g. voltage, base type) are matched to Daray Illumin8 halogen light fittings; users are instructed to use only in compatible Daray fixtures as per product codes SL200HA, SL200HAMINI, SL250W, SL250C and SL250C/250C.

Formulation

  • Non-sterile electrical replacement part (halogen capsule bulb) for Daray halogen examination/surgical lights.
  • Supplied as a pack of 3 bulbs intended solely for use in compatible Daray Illumin8 fixtures.

Packaging

  • Pack of 3 x 100W halogen capsule bulbs.
  • Marketed by Medisave UK Ltd with SKU DRK4059 and described as "Daray 100W Halogen Bulb Capsule - Pack of 3".
  • Daray’s own catalogue references the multi-buy pack for SL200 halogen lights under code DRK4059-3; some distributors may show alternative internal SKUs (e.g. DD11335) while still referring to the same 3-pack of Daray bulbs.
  • Supplied in protective packaging suitable for transport and storage of fragile halogen capsules.

Usage

  • Ensure the associated Daray Illumin8 light (e.g. SL200HA, SL200HAMINI, SL250W, SL250C or SL250C/250C) is switched off and disconnected from the mains power supply before attempting to replace a bulb.
  • Allow sufficient time for the existing halogen bulb and light head to cool completely before handling, as halogen capsules can become very hot during operation.
  • Access the lamp compartment or head of the Daray light following the specific instructions in the light’s user/installation manual.
  • Carefully remove the spent halogen capsule, avoiding excessive force on the lampholder or wiring.
  • Install the new 100W halogen capsule bulb from the pack, ensuring correct orientation and firm but gentle seating into the appropriate lampholder or socket specified for the model.
  • Avoid touching the glass envelope of the new halogen capsule with bare fingers where possible; use clean gloves or a lint-free cloth. Any fingerprints or contamination on the glass should be cleaned according to standard halogen lamp handling guidance to avoid hot spots and reduced life.
  • Reassemble the light head or lamp housing securely, ensuring any covers or lenses are properly fitted.
  • Reconnect the light to the mains supply and test operation, confirming that the light output is stable and that controls (including intensity or focus, where applicable) operate as expected.
  • Dispose of spent halogen bulbs in accordance with local waste and electrical equipment disposal policies; do not incinerate or crush bulbs without following appropriate safety guidance.
  • Only use Daray-specified replacement bulbs (such as this 100W capsule pack) in the relevant models to avoid damage to the light or reduced performance.

Contraindications

  • Not suitable for use in non-Daray or non-compatible lighting fixtures; only use in models explicitly specified as compatible (SL200HA, SL200HAMINI, SL250W, SL250C, SL250C/250C or as updated by Daray).
  • Do not use bulbs with different wattage, voltage or base than those specified by Daray for the lighting model, as this may cause overheating, damage or safety hazards.
  • Not designed for direct use as a standalone lamp or in domestic fittings.
  • Do not handle or install while the light is connected to mains power or while components are hot.

Adverse Effects

  • Risk of burns if bulbs or light heads are handled before they have cooled sufficiently after use.
  • Potential for glass breakage if the bulb is dropped or subjected to impact, presenting a laceration hazard and requiring careful clean-up.
  • Incorrect installation or use in non-compatible fittings may result in overheating, shortened bulb life or electrical faults.
  • Touching the glass envelope with bare hands can leave residues that may create hot spots, potentially reducing bulb service life or causing premature failure.

Storage Conditions

  • Store in original protective packaging in a dry, dust-free environment away from vibration and mechanical shock.
  • Avoid exposure to moisture, condensation and corrosive atmospheres that may damage contacts or the glass capsule.
  • Protect from excessive heat and direct sunlight when in storage to preserve packaging integrity and lamp components.
  • Do not stack heavy items on top of the bulb pack to prevent crushing or stress on the glass capsules.

Duration

Not applicable \u2013 this product is a replacement light source for medical lighting equipment rather than a clinical treatment. Each bulb\u2019s service life will depend on usage patterns, duty cycle and switching frequency in the associated Daray light.

Onset

Not applicable in a therapeutic sense. Once installed in a compatible Daray Illumin8 light and powered, the bulb provides immediate illumination.