Daray SL180LED Minor Surgical Light   Wall Mounted

Daray SL180LED Minor Surgical Light Wall Mounted

Daray

Lighting
  • CE marked medical device compliant with EU safety legislation
  • Manufacturer quality systems compliant with ISO 9001
  • Manufacturer quality systems compliant with ISO 13485
  • Compliant with BS EN 60601 2 41 medical electrical equipment standard
  • Compliant with IEC 60601 2 41:2000, UL60601 1 and CAN/CSA C22.2 No. 601.1 M 90 electrical safety standards (as stated in manufacturer documentation)
Minor surgical LED examination light

Description

The DARAY SL180LED Minor Surgical Light (wall mounted) is a high-performance NviroLED medical luminaire designed for minor surgical procedures and advanced examinations. It delivers a strong, evenly distributed LED light beam with 50,000 lux at 0.75 m and 35,000 lux at 1 m, a daylight-like 4,200 K colour temperature and excellent colour rendering, ensuring natural skin tones and reduced eye strain. The fully enclosed BioProtect antimicrobial light-head supports infection control, while variable intensity and smooth spring-balanced positioning make it suitable for day surgery, gynaecology, A&E, podiatry, dermatology and GP treatment rooms.

Bnefits

  • Lowest total cost of ownership minor surgical light, designed for long-term clinical use
  • Costs up to 75% less to run than equivalent halogen lights
  • Approx. 50,000 hours LED life, reducing bulb replacement and downtime
  • Strong, even LED beam with 50,000 lux at 0.75 m and 35,000 lux at 1 m for clear visibility
  • 4,200 K daylight-style colour temperature with excellent colour rendering (Ra ≈ 96) for natural tissue appearance
  • Emits no infrared radiation, so there is no increase in temperature in the light field
  • Variable intensity from 0% to 100% for precise control of illumination
  • Smooth, fully enclosed light-head with BioProtect antimicrobial coating to aid infection control
  • Multiple LEDs and optical design minimise shadows and reduce eye strain
  • Various mounting options across the SL180LED range; this configuration provides a space-saving wall-mounted solution
  • Environmentally friendly design with low power consumption, no halogen, mercury, cadmium, lead or CFCs, and fully recyclable construction at end of life

Indications

  • Minor surgical procedures performed under local anaesthetic
  • Day surgery procedures requiring focused shadow-reduced lighting
  • Gynaecological examinations and minor interventions
  • Dental implant and minor maxillofacial procedures
  • Accident and Emergency (A&E) assessment and treatment areas
  • Podiatry examinations and minor procedures
  • Dermatology examinations and minor dermatological procedures
  • Use in GP treatment rooms and outpatient procedure rooms
  • Mortuary examination lighting
  • General minor procedure and examination lighting in clinics and hospitals

Composition

  • LED light source: 24 V LED module with 12 LEDs
  • Illumination: 50,000 lux at 0.75 m (normal working distance); 35,000 lux at 1 m
  • Colour temperature: 4,200 K ± 5% (daylight style)
  • Colour rendering index (Ra): approximately 96
  • LED life: up to 50,000 hours from the LED light engine
  • Power requirement: approximately 30 W (230 V, 50 Hz supply)
  • Optical system: high-definition NviroLED technology providing an intense clear white light beam
  • Light-head housing: smooth, fully enclosed head with BioProtect antimicrobial coating
  • Mounting structure: wall-mounted spring-balanced arm system (SL180LEDW configuration)
  • Environmental design: no halogen, mercury, cadmium, lead or CFCs; fully recyclable construction at end of life

Formulation

  • Wall-mounted minor surgical LED luminaire using NviroLED technology
  • Multiple high-intensity white LEDs integrated into a fully enclosed light-head
  • Spring-balanced arm system for precise, stable positioning over the working field
  • Integrated variable-intensity electronic control (0–100%) on the light-head
  • BioProtect antimicrobial coating applied to painted surfaces and light-head for infection control

Packaging

  • 1 x DARAY SL180LEDW wall-mounted minor surgical light (light-head and arm assembly)
  • 1 x wall-mounting bracket/fixings kit (as supplied by manufacturer or distributor)
  • Integrated variable-intensity controls on light-head
  • Manufacturer documentation including installation, operation and maintenance instructions

Usage

  • Install the SL180LEDW in accordance with DARAY’s installation manual and local electrical regulations, using a qualified installer.
  • Ensure the wall structure and fixings meet the load requirements for the arm and light-head before mounting.
  • Connect the unit to the specified mains power supply (typically 230 V, 50 Hz) via an appropriate fused circuit as per manufacturer instructions.
  • After installation, use the spring-balanced arm to position the light-head above the treatment field, ensuring the beam covers the required area.
  • Switch the light on using the control on the light-head, and adjust the variable intensity from 0% to 100% to achieve the desired illumination level.
  • During procedures, reposition the arm and light-head as required using one-handed adjustments, avoiding contact with the illuminated sterile field.
  • After use, switch off the light and return the arm to a parked position to avoid accidental impact.
  • Clean the smooth, fully enclosed head and arm regularly with approved disinfectants compatible with BioProtect antimicrobial finishes, following DARAY’s cleaning guidance.
  • Perform routine visual checks of cables, arm joints and fixings, and arrange periodic servicing according to the manufacturer’s recommendations and local policies.

Contraindications

Not publicly listed

Adverse Effects

Not publicly listed

Storage Conditions

  • Store and operate in a clean, dry clinical environment in line with the environmental conditions specified by DARAY.
  • Avoid exposure to excessive moisture, corrosive chemicals or dust that could affect electrical safety or mechanical components.
  • Ensure the unit is disconnected from mains power before any maintenance requiring access to electrical components.
  • Protect the arm and light-head from impact or overloading when not in use.

Duration

Dependent on the clinical procedure; the light is intended for continuous use during minor surgical and examination sessions.

Onset

Immediate illumination at the selected intensity upon switching the light on.