Plinth 2000 Tilting Surgery Couch Electric (Model 93MPT)
Plinth Medical
Medical furnitureElectric multi-purpose tilting surgery couch / chair
Certifications
- CE marked in conformity with the EC Medical Devices Directive MDD 93/42/EEC, Annex IX Class I (as stated by the manufacturer for the multi Purpose chair range)
- Electrical safety classification to IEC 601 1 / IEC 60601 1 for medical electrical equipment (double Insulated Type B equipment for 93MP/93MPT range)
- Ingress protection rating IPX4 for the 93MP/93MPT multi Purpose chair motors and control system
- Vinyl upholstery flame Retardant to CRIB 5 (BS 5852) as per Plinth Medical technical documentation for comparable couches
- Manufactured by Plinth Medical Ltd, an ISO 9001 audited company (quality management system)
- Designed and manufactured in England with stated lifetime frame guarantee and 5 Year parts guarantee for premium range products
- CE marked in conformity with the EC Medical Devices Directive MDD 93/42/EEC, Annex IX Class I (as stated by the manufacturer for the multi Purpose chair range)
- Electrical safety classification to IEC 601 1 / IEC 60601 1 for medical electrical equipment (double Insulated Type B equipment for 93MP/93MPT range)
- Ingress protection rating IPX4 for the 93MP/93MPT multi Purpose chair motors and control system
- Vinyl upholstery flame Retardant to CRIB 5 (BS 5852) as per Plinth Medical technical documentation for comparable couches
- Manufactured by Plinth Medical Ltd, an ISO 9001 audited company (quality management system)
- Designed and manufactured in England with stated lifetime frame guarantee and 5 Year parts guarantee for premium range products
Electric multi-purpose tilting surgery couch / chair
Description
The Plinth 2000 Tilting Surgery Couch - Electric (Plinth Medical Model 93MPT) is a UK-manufactured, electric multi-purpose surgery couch designed for busy surgeries and health centres. It provides electric height adjustment and Trendelenburg tilt, with a three-section couch top whose backrest and foot section allow both seated and lying positions. Standard accessories include phlebotomy armrests and gynaecology stirrups, making it suitable for phlebotomy, minor surgery, recovery, gynaecology, podiatry and general examination, with a safe working load of 250 kg and long service life.
Bnefits
- UK-manufactured multi-purpose surgery couch designed for busy surgeries and health centres
- Covers multi-purpose needs including phlebotomy, minor surgery, recovery, gynaecology, podiatry and general examination
- Electric operation of height and Trendelenburg tilt (seat tilt to approximately -20°) for flexible patient positioning
- Foot section can drop to approximately -90° to create a compact chair position and improve access in small treatment rooms
- Safe working load of 250 kg (approximately 39 stone / 550 lb) for a wide range of patients
- Comfort foam upholstery to enhance patient comfort during longer procedures
- Hardwearing, fully washable anti-microbial vinyl upholstery with wide range of colour options
- Retractable castors to allow easy movement and positioning of the couch within the clinic
- Hoist clearance of around 130 mm beneath the frame for use with mobile hoists
- Supplied as standard with phlebotomy armrests and gynaecology stirrups for specialised procedures
- Breathing hole and plug available for prone treatments
- Lifetime frame guarantee and 5-year parts guarantee with an average quoted lifespan of around 16 years
- Easy, low-running-cost electric operation via hand or optional foot control to reduce manual handling
- Space-saving frame design allowing installation even in smaller treatment rooms
Indications
- Positioning and support of patients for general medical examination in primary and secondary care settings
- Use as a multi-purpose chair/couch for phlebotomy and blood collection procedures
- Minor surgery and outpatient procedures requiring flexible patient positioning
- Gynaecology examinations and minor procedures using the supplied stirrups
- Podiatry and lower limb treatments using tilt and foot section adjustment
- Patient recovery following minor procedures or episodes of faintness while seated or reclined
- Use in GP surgeries, outpatient departments, private clinics and day surgery centres
Composition
- Heavy-duty welded steel base and column frame, designed for clinical use
- Three-section couch top comprising head/backrest, seat and foot sections
- Comfort foam cushions (high-density foam) on all top sections
- Hardwearing anti-microbial, fire-retardant vinyl upholstery (multiple Ambla-type colour options)
- Electric actuator motors for height adjustment and Trendelenburg/seat tilt (twin-motor configuration for 93MPT)
- Retractable swivel castors operated via pedals for mobility
- Adjustable stabilising foot to ensure couch stability on uneven floors
- Standard fitting phlebotomy armrests and lithotomy/gynaecology stirrups
- Integrated breathing hole and plug for prone treatments (as specified for the range)
Formulation
- Electric multi-purpose three-section couch/chair with adjustable backrest, seat tilt and foot section
- Electric height adjustment to provide low patient transfer height (around 52 cm) and working height up to approximately 101 cm
- Electric Trendelenburg seat tilt (to around -20°) enabling head-down or head-up positioning for procedures and recovery
- Manually adjustable or motor-assisted backrest to support seated or semi-recumbent positions
- Foot section able to lower to approximately -90° to create compact seated configuration and improve practitioner access
- Retractable castor system allowing the couch to be wheeled into position when unoccupied and locked down for use
- Three-section design allows supine, prone, semi-reclined and seated postures, as well as lithotomy positioning with stirrups
- Rated for continuous clinical use as a Class I medical device examination/treatment couch
Packaging
Not publicly listed
Usage
- Position the couch on a firm, level surface and adjust the stabilising foot so that the frame is stable when the castors are retracted.
- Ensure the retractable castors are retracted and the couch is stable before a patient gets on or off the couch.
- Connect the mains lead to a suitable earthed power outlet, ensuring that cables are undamaged and routed to avoid trip hazards.
- Use the hand control (and optional footswitch, if fitted) to adjust couch height and Trendelenburg tilt with the patient already safely positioned.
- Adjust the backrest and foot section using the appropriate electric or gas-spring controls, supporting the section during movement and locking in the desired position.
- Use the Trendelenburg tilt and backrest functions to return the patient to a more horizontal or head-down recovery position if they feel faint or light-headed.
- Set and lock phlebotomy arms at appropriate height, angle and rotation before inserting or removing needles, confirming that all thumbwheels and clamps are tight.
- Adjust and lock gynaecology stirrups securely before use, ensuring the patient is safely and comfortably positioned.
- Clean the couch between patients using warm water and neutral detergent on a damp cloth, followed by a rinse with clean water and thorough drying.
- For decontamination, use a suitable dilute hypochlorite solution (for example up to 10,000 ppm available chlorine) according to local infection control policies, then rinse and dry and dispose of cleaning materials safely.
- Inspect upholstery regularly and replace any torn or damaged sections promptly to maintain infection control and safety.
- Carry out routine six-monthly checks of bolts, gas struts, moving parts and electrical leads, and arrange annual servicing by a qualified engineer as recommended by the manufacturer.
- Disconnect the power supply when the chair is not in use for extended periods or before carrying out cleaning, maintenance or moving the chair.
Contraindications
Not publicly listed
Adverse Effects
Not publicly listed
Storage Conditions
- Store and operate the couch indoors in a dry clinical environment within the temperature and humidity ranges specified by the manufacturer.
- Ensure the couch is disconnected from the mains supply before long-term storage or when not in regular use.
- Avoid exposure to corrosive cleaning chemicals, strong alkalis or organic solvents that are not approved for use on the upholstery or frame.
- Do not store or operate the couch in the presence of flammable anaesthetic gases or vapours.
- Keep the area around the couch free from clutter so that castors, pedals and cables are not obstructed.
Duration
Onset
| Price | Link |
|---|---|