Hanning Handswitch H/S1
Plinth Medical
Medical furniture & accessoriesCouch accessories \u2013 hand and foot switches
Certifications
- Manufactured and supplied under an ISO 9001 Certified quality management system (Plinth Medical Ltd.)
- CE marking indicated by manufacturer in line with applicable medical device regulations for couch systems and accessories
- Manufactured and supplied under an ISO 9001 Certified quality management system (Plinth Medical Ltd.)
- CE marking indicated by manufacturer in line with applicable medical device regulations for couch systems and accessories
Couch accessories \u2013 hand and foot switches
Description
The Hanning Handswitch H/S1 is a replacement hand control designed for treatment and examination couches fitted with Hanning SL80, SL95 or KL95 linear actuators. Using a pneumatic fitting, it allows the operator to conveniently control couch movements such as raising and lowering from a hand-held switch, providing reliable patient positioning in clinical environments including medical, therapy and aesthetic practices.
Bnefits
- Compatible with Hanning SL80, SL95 and KL95 actuators used on many medical and therapy couches
- Pneumatic hand control enables convenient high/low adjustment from the couch side
- Intended as an OEM-quality spare part for Plinth Medical couches and similar systems
- Simple, intuitive operation for clinical staff
- Supports safe and efficient patient positioning during examinations and treatments
Indications
- Replacement or spare hand control for couches using Hanning SL80, SL95 or KL95 actuators
- For electrically adjustable medical, therapy or treatment couches in clinics, hospitals and aesthetic practices
- Situations where hand-operated couch control is preferred over or in addition to a footswitch
Composition
- Handheld control housing with integrated pneumatic push buttons
- Pneumatic hose connection compatible with Hanning actuator systems
- Internal pneumatic switching mechanism designed for SL80/SL95/KL95 actuators
Formulation
- Non-sterile, reusable pneumatic hand control for medical/treatment couches
Packaging
- Single Hanning Handswitch H/S1 unit (Plinth Part No: HHS1)
Usage
- Ensure the couch is disconnected from mains power and secured according to the couch manufacturer’s instructions before installing or replacing the hand switch.
- Connect the hand switch pneumatic hose to the appropriate Hanning actuator control port, ensuring a secure and leak-free fit.
- Recheck that the cable/hose routing does not create trip hazards or pinch points around the couch.
- Reconnect power to the couch and test all hand switch functions (e.g. raise and lower) without a patient on the couch.
- Use the hand switch buttons to control couch movement during patient positioning, following the couch manufacturer’s operating instructions at all times.
- Do not allow patients or untrained persons to operate the hand switch.
Contraindications
- Do not use with actuator systems other than compatible Hanning SL80, SL95 or KL95 units unless confirmed by the couch manufacturer.
- Do not use if the hand switch housing, hose or connectors appear damaged, cracked, kinked or excessively worn.
- Not intended for use in explosive or flammable atmospheres unless the entire couch system is specifically approved for such environments.
- Not intended to be operated by patients or untrained users.
Adverse Effects
- Potential risk of patient discomfort or minor injury if couch movements are not controlled appropriately while using the hand switch.
- Pinch or crush hazard to limbs or accessories if moving parts of the couch are not kept clear during adjustment.
- Trip or entanglement hazard if the hand switch hose is allowed to trail or lie across walkways.
Storage Conditions
- Store in a clean, dry environment when not installed on a couch.
- Avoid prolonged exposure to direct sunlight, excessive heat, moisture or chemical agents that may degrade plastics or hose materials.
- Do not place heavy objects on top of the hand switch or hose to avoid deformation or damage.
Duration
Used as needed during each adjustment of the examination or treatment couch; no fixed treatment duration applies.
Onset
Immediate mechanical response of the couch/actuator when the appropriate button is pressed, provided the system is correctly installed and powered.