Logo
HOME
All FeaturesClinic Management SoftwareHIPAA Compliant Medical Spa Software
BLOGFAQS
Register a ClinicRegister as a Practitioner
BOOK DEMO
Are you a Practitioner?

Join over 200+ clinics already growing with Consentz.

BOOK DEMO

Contacts

(UK) +44 (0) 208 050 3372

(US) +1 646 786 1949

contact@consentz.com

Consentz vs

  • Zenoti
  • AestheticsPro
  • Pabau
  • Aesthetic Record
  • Clinicsense
  • Nextech
  • Vagaro
  • GlowdayPRO
  • PatientNow
  • Mangomint
  • Boulevard

Features

  • Clinic Management
  • Patient Engagement
  • Photos and Records
  • Personalise
  • Analytics
  • Stock and Billing

Features

  • Marketing
  • Medical Templates
  • FAQs
  • Blog
  • Articles
  • Support
  • Terms & Conditions
  • Partners
  • Privacy Policy
  • Sitemap

Get the app

Download Consentz on the App Store
Consentz

Find qualified healthcare and aesthetic practitioners in your area. Verified profiles, authentic reviews, and regulatory compliance.

For Practitioners

  • Join Directory
  • Update Profile
  • Verification Process
  • Support

Directory

  • Aesthetic Treatments
  • Top Aesthetic Practitioners
  • Top Aesthetic Clinics
  • Accredited Clinics
  • Top Clinics by Treatment & City
  • Top Practitioners by Treatment & City
  • Aesthetic Product Brands
  • Aesthetic Product Categories

Clinics by Accreditation

  • CQC Accredited Clinics
  • HIS Accredited Clinics
  • HIW Accredited Clinics
  • JCCP Accredited Clinics
  • RQIA Accredited Clinics
  • Save Face Accredited Clinics

Practitioners by Accreditation

  • CQC Accredited Practitioners
  • HIS Accredited Practitioners
  • HIW Accredited Practitioners
  • JCCP Accredited Practitioners
  • RQIA Accredited Practitioners
  • Save Face Accredited Practitioners

Consentz Hub

  • Buyer Hub
  • Aesthetic Clinic Software
  • Templates
  • By City

© 2026 Consentz. All rights reserved.

  1. Home
  2. Products
  3. Qlicksmart
  4. qlicksmart-snapit-ampoule-opener-trolley-regular-black
Qlicksmart SnapIT Ampoule Opener   Trolley Regular   Black

Qlicksmart SnapIT Ampoule Opener Trolley Regular Black

Qlicksmart

Medical device
Reusable ampoule opener / sharps safety device

Certifications

  • FDA Listed medical device in the United States under product code MDM (Instrument, manual, surgical, general use), Class I.
  • GMDN term code 10098 – Ampule opener (reusable device intended to safely open glass ampoules).
  • Manufactured by Qlicksmart Pty Ltd, whose quality management system is accredited to ISO 13485 for medical devices.
  • Designed and marketed as a sharps safety product to support compliance with occupational sharps injury prevention guidelines.
  • Non Sterile, re Usable medical device; validated as autoclavable up to 130 °C (266 °F) for appropriate infection control procedures.
  • FDA Listed medical device in the United States under product code MDM (Instrument, manual, surgical, general use), Class I.
  • GMDN term code 10098 – Ampule opener (reusable device intended to safely open glass ampoules).
  • Manufactured by Qlicksmart Pty Ltd, whose quality management system is accredited to ISO 13485 for medical devices.
  • Designed and marketed as a sharps safety product to support compliance with occupational sharps injury prevention guidelines.
  • Non Sterile, re Usable medical device; validated as autoclavable up to 130 °C (266 °F) for appropriate infection control procedures.
Reusable ampoule opener / sharps safety device

Description

The Qlicksmart SnapIT Ampoule Opener - Trolley Regular - Black is a reusable, anodised aluminium ampoule opener designed to safely open scored glass ampoules and reduce sharps and needlestick injuries. The Trolley Edition features a flat side so it can sit securely on a bench or medication trolley without rolling, and the Regular size is compatible with common ampoule volumes from 1–2 mL, 5–10 mL and 10–15 mL. A quick “insert and snap” lever action securely holds the ampoule lid inside the device, allowing it to be ejected directly into a sharps container, minimising the risk of cuts, contamination and medication loss.

Bnefits

  • Helps prevent cuts and sharps injuries when opening glass ampoules by hand.
  • Easy “insert and snap” one-step action for quick, consistent ampoule opening.
  • Flat-sided Trolley Edition prevents rolling off benches and trolleys in clinical areas.
  • Regular size compatible with most 1–2 mL, 5–10 mL and 10–15 mL scored glass ampoules.
  • Reusable multi-use device that can be autoclaved up to 130 °C (266 °F) for sterilisation.
  • Ampoule lid remains enclosed inside the device until ejected directly into a sharps container, reducing glass exposure.
  • Reduces medication wastage from broken ampoules and contaminated contents.
  • Latex-free and DEHP-free construction, suitable for sensitive users.
  • Cost-effective sharps safety solution compared with disposable ampoule openers.
  • Lightweight aluminium construction with extended lever action for low-effort opening and reduced wrist strain.

Indications

  • For healthcare professionals who need to safely open scored glass ampoules containing injectable medicines.
  • Use in hospitals, clinics, emergency departments, operating theatres, intensive care, anaesthesia, and outpatient settings.
  • Suitable where prevention of needlestick and sharps injuries from ampoule opening is a priority.
  • Regular Trolley model specifically indicated for scored glass ampoules of approximately 1–2 mL, 5–10 mL and 10–15 mL (size guidance only; compatibility depends on ampoule geometry).

Composition

  • Body: anodised aluminium.
  • Internal O-ring: silicone rubber.
  • Spring mechanism: stainless steel.
  • Keyring / attachment hardware (where supplied): stainless steel.
  • Device is latex-free and DEHP-free.
  • Non-sterile multi-use device; autoclavable up to 130 °C (266 °F) for SnapIT Trolley editions.

Formulation

  • Device type: multi-use manual ampoule opener.
  • Edition: SnapIT Trolley Ampoule Opener – Aluminium.
  • Model: Trolley Edition, size Regular, colour Black.
  • Compatible ampoule sizes (Regular Trolley): 1–2 mL, 5–10 mL, 10–15 mL scored glass ampoules (actual compatibility depends on ampoule neck geometry and lid diameter).
  • Dimensions for Trolley Regular (TE-01R): approximate length 80 mm; width 25 mm.
  • GMDN code: 10098 (Ampule opener).
  • Regulatory classification: manual surgical instrument, general use; FDA product code MDM, Class I.
  • Reusability: multi-use device; O-ring can be replaced if lost or damaged.
  • Sterility: supplied non-sterile; can be autoclaved up to 130 °C (266 °F) if required.

Packaging

  • Single SnapIT Trolley Ampoule Opener, Regular size, Black, per retail pack (TE-01R).
  • Packaged as a reusable device with instructions for use and cleaning.
  • Outer packaging type may vary by distributor (e.g., boxed or blister-style retail pack), but contents are one ampoule opener per unit.
  • Intended for repeated use in clinical environments; not supplied as a sterile, single-use product.

Usage

  • Verify that the SnapIT Trolley Regular model is compatible with the ampoule size and neck geometry; do not force the ampoule if it does not easily fit.
  • If the glass ampoule is scored with a dot, align the dot on the ampoule with the dot on the SnapIT body.
  • Insert the entire ampoule lid (top of the ampoule above the score line) into the opening of the SnapIT until it locks at the neck.
  • While holding the ampoule body with your free hand, lever the SnapIT away from your body (and away from the dot) in a smooth motion to snap the lid off.
  • Ensure the glass lid remains captured inside the SnapIT device after snapping.
  • Position the SnapIT opening over an appropriate sharps container.
  • Press down on the internal rod or key mechanism to eject the captured ampoule lid directly into the sharps bin without touching it.
  • Inspect the open ampoule for any visible glass fragments before withdrawing medication, following local protocols.
  • Clean the SnapIT regularly according to institutional procedures: disassemble by removing the keyring and O-ring, wash with water and a suitable medical-grade cleaner, rinse, dry thoroughly and reassemble.
  • If a “bad” ampoule shatters inside the device, tap the SnapIT gently over a sharps bin to remove excess glass, then rinse and clean before next use; replace the O-ring if damaged.
  • Autoclave the SnapIT Trolley as required for infection control, ensuring autoclave settings do not exceed 130 °C (266 °F).

Contraindications

  • Do not use with non-scored glass ampoules; the device is designed for scored ampoules only.
  • Do not use if the ampoule does not easily fit into the SnapIT opening or if the ampoule neck geometry is incompatible; forcing the ampoule may cause breakage and injury.
  • Do not use on damaged, cracked or previously compromised ampoules.
  • Do not use if the SnapIT device itself is visibly damaged, deformed, or if the O-ring or internal components are missing or excessively worn.
  • Not intended for opening plastic ampoules or vials.
  • Follow institutional policies for sharps safety; users who have not been trained in safe ampoule opening techniques should receive appropriate instruction before use.

Adverse Effects

  • Residual risk of cuts or sharps injury if the device is used incorrectly, if an ampoule shatters during opening, or if incompatible ampoules are forced into the device.
  • Potential glass contamination of medication if an ampoule breaks irregularly; contents should be discarded according to local policy.
  • Minor pinching or impact injuries to fingers or hands if grip and leverage are not properly controlled.
  • Thermal injury risk if the device is handled immediately after autoclaving without adequate cooling time.
  • Allergic or sensitivity reactions are unlikely due to silicone and metal construction but should be considered in users with known material sensitivities.

Storage Conditions

  • Store the device clean, dry and protected from dust and contaminants between uses.
  • Keep in a designated sharps-safety or medication preparation area, such as a medication trolley, bench top or drawer, ensuring the flat side rests securely to prevent rolling.
  • Avoid exposure to corrosive chemicals or environments which could damage aluminium or stainless steel components.
  • After cleaning or autoclaving, allow the device to dry and cool completely before storage and reuse.
  • Inspect periodically for wear, corrosion or damage and replace the device or O-ring if necessary.

Duration

Not applicable \u2013 mechanical ampoule opening device used briefly at the time of medicine preparation; intended for long-term multi-use with routine cleaning and maintenance.

Onset

Immediate \u2013 provides safe ampoule opening at the time of use.
PriceLink
£52.79https://www.medisave.co.uk/products/qlicksmart-snapit-ampoule-opener-personal-regular-blue
PriceLink
£64.79https://www.medisave.co.uk/products/qlicksmart-snapit-ampoule-opener-trolley-large-red
PriceLink
£58.79https://www.medisave.co.uk/products/qlicksmart-snapit-ampoule-opener-trolley-regular-black

Browse more Medical device

BladeFlask EVO Scalpel Blade Remover and Bin

BladeFlask EVO Scalpel Blade Remover and Bin

Medisave

BladeFlask EVO Scalpel Blade Remover and Bin

Clinic Essentials
  • £39.59
  • -1 more

Top Treatments

Acne

Acne
Acne

Aesthetic Skin Consultation

Aesthetic Skin Consultation
Aesthetic Skin Consultation

Alopecia

Alopecia
Alopecia

Anti Wrinkle Treatment

Anti Wrinkle Treatment
Anti Wrinkle Treatment

Aqualyx

Aqualyx
Aqualyx

Aviclear

Aviclear
Aviclear

B12 Injection

B12 Injection
B12 Injection

Birthmarks

Birthmarks
Birthmarks

Botox

Botox
Botox

Breast Augmentation

Breast Augmentation
Breast Augmentation

Cheek Enhancement

Cheek Enhancement
Cheek Enhancement

Top Cities in the UK

4QR
Aberaeron
Aberdare
Aberdeen
Aberfeldy
Abergavenny
Aberpwll
Abertillery
Aberystwyth
Abingdon
Accrington
Airdrie
Alderley
Alderminster
Alexandria