TSK THE INViSIBLE NEEDLE 34G x 9mm (LDS 02009 100)
TSK
Medical Consumables
Hypodermic / Aesthetic Injection Needles
Certifications
CE Marked medical device (hypodermic single lumen needle)
Manufactured in compliance with applicable European medical device standards for hypodermic needles
CE Marked medical device (hypodermic single lumen needle)
Manufactured in compliance with applicable European medical device standards for hypodermic needles
Hypodermic / Aesthetic Injection Needles
Description
TSK THE INViSIBLE NEEDLE 34G x 9mm is an ultra-thin, low dead space (LDS) hypodermic needle designed for highly precise aesthetic and medical injections, especially botulinum toxin (BoNT) and dermal fillers. With a diameter of 0.2 mm and length of 9 mm (3/8\), it is approximately 33% thinner than a standard 30G needle and 14% thinner than the TSK 33G needle, offering a near-painless injection experience with minimal bleeding and bruising. The patented LDS hub minimises product loss and improves cost-efficiency when injecting high-value drugs.
Bnefits
Thinnest toxin needle on the market in its class (34G, 0.2 mm diameter)
Approximately 33% thinner than a standard 30G needle and 14% thinner than the TSK 33G needle
Near-painless injections with minimal bleeding for improved patient comfort
Low Dead Space (LDS) hub design reduces residual volume and product loss (saves up to ~0.08 ml BoNT per needle)
Helps achieve significant cost savings when injecting high-cost drugs such as botulinum toxin
50% better glide and penetration compared with conventional needles (less insertion force)
Reduced risk of bruising and tissue trauma
External hub threading reduces pop-off risk and prevents leakage at the luer connection
Hard polymer hub prevents flexing under pressure and improves stability
High-precision Japanese manufacturing for consistent quality and sharpness
Sterile, single-use needle for safe clinical practice
Indications
Injection of botulinum toxin (BoNT) for aesthetic and therapeutic indications
Highly precise intradermal or subcutaneous injections in facial aesthetics (fine lines, localised treatments)
Dermal filler micro-injections where an ultra-fine sharp needle is indicated
Mesotherapy or toxin-based skin treatments that benefit from a very fine needle
Selected ophthalmology injections where a 34G, 9 mm sharp needle is clinically appropriate (per manufacturer labelling)
Other medical and cosmetic injection procedures suitable for a 34G x 9 mm sharp hypodermic needle, performed by trained professionals
Composition
Needle: 34G stainless steel hypodermic needle, 0.2 mm x 9 mm (3/8")
Hub: Low Dead Space (LDS) hard polymer hub with external threading for secure luer lock connection
Kind: Sharp hypodermic toxin needle (nanoneedle) for BoNT and ophthalmology / aesthetic use
Formulation
Sterile, non-pyrogenic, single-use hypodermic needle with Low Dead Space hub
Sharp toxin needle (34G nanoneedle) with external threaded hard polymer hub
Packaging
Box of 100 needles
Each needle supplied in individual sterile packaging (blister/pouch) labelled as TSK THE INViSIBLE NEEDLE 34G x 9mm (LDS-02009-100)
Usage
For professional medical use only in a clinical setting by appropriately trained physicians (e.g., dermatologists, aesthetic doctors, ophthalmologists) or licensed healthcare professionals.
Check the integrity of the outer box and individual sterile packs; do not use if packaging is damaged, opened, or expired.
Attach the needle securely to a compatible luer-lock or luer-slip syringe, ensuring proper engagement with the external threading of the LDS hub.
Prime the needle as required and follow the specific product protocol for the drug being injected (e.g., botulinum toxin reconstitution, dosage and injection depth).
Insert the needle into the target tissue (typically intradermal or subcutaneous for toxin) using an appropriate angle and technique according to clinical guidelines.
Inject slowly and steadily, monitoring patient comfort and tissue response; use multiple small injections as indicated rather than large boluses.
After completing injections, withdraw the needle carefully and apply gentle pressure or cooling as needed to minimise bruising.
Dispose of the used needle immediately in an approved sharps container; do not recap and do not reuse this single-use device.
Contraindications
Do not use in patients with known hypersensitivity or allergy to stainless steel or any component of the needle if such reactions have been documented.
Do not use at injection sites with active infection, inflammation, dermatitis, or open wounds.
Not suitable for use by untrained or non-qualified personnel.
Do not use if sterile packaging is damaged, opened or past the stated expiry date.
Use only for hypodermic injection; not intended for use in central vascular access or procedures outside the approved indications.
Adverse Effects
Local pain or discomfort at the injection site related to needle puncture.
Minor bleeding or spotting at injection points.
Bruising, swelling or small haematoma formation, though risk is reduced compared with larger-gauge needles.
Very rare local infection if aseptic technique is not followed.
Potential tissue irritation or trauma if injection technique is incorrect or if the needle is forced against resistance.
Storage Conditions
Store in a clean, dry environment at room temperature.
Protect from moisture, excessive heat and direct sunlight.
Keep in original packaging until use to maintain sterility.
Keep out of reach of children.
Duration
Not directly applicable to the device; the needle is used for single-session injections and then discarded. Duration of clinical effect depends on the injectable product (e.g., botulinum toxin or filler) and treatment protocol.
Onset
Not applicable to the needle itself; onset and duration of effect are determined by the drug injected (e.g., botulinum toxin, dermal filler) and anatomical site.