BD Plastipak™ 1ml Syringe With Detached BD Microlance™ 3 Needle Box of 120
Becton Dickinson
Medical device - syringe and hypodermic needle combination
1 ml three-piece Luer slip syringe with detached 30G x 13 mm hypodermic needle
Certifications
Class IIa medical device in accordance with European medical device classification.
Manufactured under an ISO 13485 Compliant quality management system for medical devices.
Syringe performance and volumetric accuracy in line with ISO 7886 1 standards for sterile hypodermic syringes (BD Plastipak™ family).
Needle dimensions, colour coding and performance characteristics consistent with ISO standards for hypodermic needles (BD Microlance™ 3 family).
Latex Free and single Use, sterile EO Processed device in accordance with applicable regional regulations for sterile medical devices.
Class IIa medical device in accordance with European medical device classification.
Manufactured under an ISO 13485 Compliant quality management system for medical devices.
Syringe performance and volumetric accuracy in line with ISO 7886 1 standards for sterile hypodermic syringes (BD Plastipak™ family).
Needle dimensions, colour coding and performance characteristics consistent with ISO standards for hypodermic needles (BD Microlance™ 3 family).
Latex Free and single Use, sterile EO Processed device in accordance with applicable regional regulations for sterile medical devices.
1 ml three-piece Luer slip syringe with detached 30G x 13 mm hypodermic needle
Description
The BD Plastipak™ 1ml Syringe With Detached BD Microlance™ 3 Needle is a sterile, single-use syringe and needle combination designed for precise low-volume injections. The set combines a 1 ml BD Plastipak™ three-piece syringe with a concentric Luer slip tip and a separate BD Microlance™ 3 hypodermic needle, 30G x 13 mm (½\), colour-coded yellow. The clear barrel with fine graduation markings supports accurate dose setting, while the three-piece construction with silicone-lubricated plunger provides smooth, leak-tight performance. The BD Microlance™ 3 needle features a thin-walled, triple-bevelled, silicone-coated stainless-steel cannula for sharp, low-resistance skin penetration and reduced patient discomfort. The product is classified as a Class IIa medical device and is ethylene oxide sterilised, supplied as a box of 120 individually wrapped combinations for clinical, medical, and aesthetic injection procedures.
Bnefits
Includes a 1 ml BD Plastipak™ three-piece syringe with concentric Luer slip tip for secure needle attachment and precise low-volume dosing.
Clear syringe barrel with finely printed graduation scale (0–1 ml) to support accurate measurement of small medication volumes.
Three-piece design with elastomeric plunger tip and silicone lubrication enables smooth plunger travel and reliable, leak-tight performance.
Detached BD Microlance™ 3 hypodermic needle, 30G x 13 mm (½"), thin-walled and triple bevelled for sharp, low-resistance penetration and improved patient comfort.
Yellow colour-coded hub for quick visual identification of 30G needles according to international colour standards.
EO (ethylene oxide) sterilisation and single-use design help to minimise infection risk and cross-contamination.
Compatible with general-purpose injection and aspiration from vials, ampoules and subcutaneous sites in a wide range of clinical settings.
Latex-free construction (no natural rubber latex in the material formulation) helps reduce the risk of latex-related reactions.
Compact 1 ml format is widely used in aesthetics and dermatology for precise delivery of small doses, such as local anaesthetic or other injectable therapies.
Indications
General-purpose injection and aspiration of fluids from vials and ampoules using a 1 ml syringe.
Subcutaneous and intradermal injections where a fine 30G needle and low-volume syringe are clinically appropriate.
Administration of small medication doses, such as vaccines, allergy desensitisation agents, heparin or other drugs, as per local clinical protocols.
Use in aesthetics and dermatology for precise administration of injectable treatments (e.g. local anaesthetic, small-volume adjunctive medications) when performed by appropriately trained professionals.
Procedures requiring a fine-gauge needle to minimise tissue trauma and improve patient comfort.
Composition
Syringe barrel: transparent medical-grade polypropylene, with printed black graduation scale up to 1 ml.
Plunger rod: polypropylene plunger with elastomeric plunger tip, lubricated with silicone oil to provide smooth movement.
Tip: concentric Luer slip adapter compatible with BD Microlance™ 3 and other Luer-based hypodermic needles.
Needle: BD Microlance™ 3 hypodermic needle, 30G x 13 mm (½"), thin-walled stainless-steel cannula with triple-bevel tip and silicone coating for low penetration resistance.
Needle hub: colour-coded yellow plastic hub, compliant with ISO colour coding for 30G needles.
Sterilisation: ethylene oxide (EO) sterilised, sterile interior for syringe and needle.
Latex-free construction and PVC-free needle hub and syringe components, non-pyrogenic and single-use.
Formulation
Sterile, single-use syringe and hypodermic needle set comprising a 1 ml three-piece BD Plastipak™ Luer slip syringe and a detached BD Microlance™ 3 30G x 13 mm needle, EO-sterilised, latex-free, designed for accurate low-volume medication delivery.
Packaging
Box of 120 BD Plastipak™ 1 ml syringe and BD Microlance™ 3 30G x 13 mm needle combinations.
Each syringe and needle set is individually packaged in a sterile blister or peel pack to maintain aseptic integrity until use.
Outer carton printed with product name, BD branding, reference/SKU 303177, gauge and length of the needle (30G x 13 mm), quantity (120), sterilisation method (ethylene oxide), classification (Class IIa), lot number and expiry date.
Packaging configuration suitable for clinical environments, allowing organised storage, stock rotation and easy identification alongside other needles and syringes.
Usage
Check the outer carton and individual blister for integrity and expiry date; do not use if packaging is damaged or expired.
Open the sterile pack using aseptic technique and remove the syringe and detached BD Microlance™ 3 needle without touching critical sterile areas.
Attach the needle hub firmly to the concentric Luer slip tip of the syringe, ensuring a secure connection.
Draw the prescribed medication from a vial or ampoule into the syringe, tapping gently to release air bubbles and adjusting the plunger so that the plunger edge aligns precisely with the required graduation marking.
Expel any remaining air from the syringe in accordance with local policy before injection.
Select and prepare the injection site according to clinical guidelines (e.g. skin disinfection, appropriate injection depth and angle for the route of administration).
Perform the injection using established clinical technique, depressing the plunger smoothly to deliver the dose.
Withdraw the needle and apply local pressure or dressing as required; do not recap the needle unless local safety policy specifically permits and safe recapping technique is used.
Immediately dispose of the used syringe and needle as a single unit into an approved sharps container.
Do not reuse; BD Plastipak™ syringes and BD Microlance™ needles are sterile, single-use devices.
Contraindications
Do not use in patients with known hypersensitivity or allergy to stainless steel or any component materials of the syringe or needle.
Not suitable for infusion or applications requiring large-volume delivery; this product is designed for low-volume injections (1 ml capacity).
Do not use if the sterile packaging is opened, damaged, wet or otherwise compromised before use.
Single-use only; reuse may increase the risk of infection, cross-contamination, needle dulling or device failure.
Use of a 30G needle may be inappropriate for high-viscosity solutions that cannot pass easily through a fine-gauge cannula; in such cases, select a larger gauge needle in accordance with clinical guidance.
Adverse Effects
Local injection-site reactions, such as pain, redness, swelling, bruising or minor bleeding, may occur as with any injection.
Risk of infection at the injection site if aseptic technique is not followed.
Potential for tissue trauma, nerve injury or haematoma if injection technique or site selection is inappropriate.
Risk of needlestick injury to healthcare workers if standard sharps precautions are not observed.
Allergic or sensitivity reactions to device materials are rare but may occur in susceptible individuals.
Storage Conditions
Store in a clean, dry environment at normal room temperature, away from direct sunlight and extremes of heat or cold.
Keep the product in its original packaging until use to protect sterility and prevent contamination or mechanical damage.
Do not expose the packaging to excessive moisture or crushing forces that may compromise integrity.
Do not use the product beyond the expiry date printed on the packaging.
Store in a secure area in accordance with local policies, out of reach of unauthorised persons and children.