UK designed and manufactured medical couch by Plinth Medical Ltd., supplied through regulated medical distributors.
Manufactured under medical furniture quality systems consistent with UK healthcare furniture requirements.
Upholstery specified as hardwearing anti Microbial vinyl suitable for healthcare environments and compatible with standard infection Control cleaning protocols.
UK designed and manufactured medical couch by Plinth Medical Ltd., supplied through regulated medical distributors.
Manufactured under medical furniture quality systems consistent with UK healthcare furniture requirements.
Upholstery specified as hardwearing anti Microbial vinyl suitable for healthcare environments and compatible with standard infection Control cleaning protocols.
Electric bariatric 2-section treatment couch
Description
The Bariatric 2 Section Plinth (Plinth Medical Model 50E) is a heavy-duty electric treatment couch designed to safely lift and position large and very heavy patients. UK manufactured, it features electric operation of both height and backrest, a wide treatment surface and a safe working load and lifting capacity of 320 kg. The couch is upholstered in hardwearing anti-microbial vinyl over comfort foam and is supplied with a breathing hole as standard. Retractable castors and 140 mm hoist clearance enable easy movement and hoist access, while the robust frame is backed by a lifetime frame and 5-year parts guarantee and an average service life of around 16 years. Optional accessories such as arms, divided legs and cotsides can transform the unit into a truly multi-purpose bariatric couch.
Bnefits
Heavy-duty bariatric couch designed to safely lift and position very heavy patients (safe working load and lift capacity 320 kg).
Electric operation of height and backrest allows effortless push-button adjustment, improving ergonomics and reducing clinician strain.
Wide treatment surface provides stable, comfortable support for large and bariatric patients.
Hardwearing anti-microbial vinyl upholstery supports infection control and is easy to wipe clean.
Comfort foam provides a supportive yet comfortable surface, with optional upgrades to deeper, pressure-relieving foam and multi-stretch vinyl.
Retractable castors and 140 mm hoist clearance facilitate easy movement and compatibility with mobile hoists.
Motorised backrest allows precise patient positioning for examination and treatment.
Breathing hole and plug are supplied as standard to support prone treatments.
UK designed and manufactured with a lifetime frame guarantee, 5-year parts guarantee and an average lifespan of around 16 years, offering low running costs and long-term value.
Can be fitted with arms, divided legs, cotsides and other accessories to create a versatile multi-purpose couch for different departments.
Indications
Examination and treatment of bariatric and heavy patients in hospital, clinic, physiotherapy, rehabilitation and outpatient settings.
Use in departments where safe lifting and positioning of large or very heavy patients is required (e.g. physiotherapy, obesity services, general practice, community hospitals).
Situations where electric height and backrest adjustment are needed to optimise clinician ergonomics and patient comfort.
General treatment couch applications requiring a higher safe working load than standard couches.
Composition
Heavy-duty steel couch frame with welded construction and powder-coated finish.
High-density comfort foam on top sections, with optional deeper/pressure-relieving foam upgrade.
Electric actuators (e.g. Linak or equivalent) for height and backrest operation.
Retractable twin-wheel castors for mobility and positioning.
Plastic and rubber components for trims, feet and cable management.
Integrated breathing hole and removable plug in head section.
Formulation
Two-section electric bariatric couch with separate backrest and main section.
Electric height adjustment and motorised backrest controlled via handset or footswitch (depending on configuration).
Safe working load and lift capacity: 320 kg.
Hoist clearance: approximately 140 mm beneath frame.
Retractable heavy-duty castor base with adjustable foot for uneven floors.
Standard features: UK manufactured frame, lifetime frame & 5-year parts guarantee, 16-year average lifespan, comfort foam, anti-microbial vinyl, breathing hole.
Optional accessories: CPR motor back, battery back-up, folding cotsides, paper roll holder, double foam/pressure-relief upgrade, wide top variants.
Packaging
Supplied as a single fully assembled or partially assembled couch unit (depending on delivery method), typically delivered direct from manufacturer or distributor.
Heavily protected with transit packaging, corner protectors and wrapping suitable for large medical furniture.
Custom upholstery colour and accessory options specified at order; order is built to configuration and delivered on a direct-order basis.
Delivery requirements (e.g. access via side streets, narrow hallways or stairwells) must be communicated in advance for appropriate arrangements.
Usage
Install and commission the couch according to the manufacturer’s instructions, ensuring adequate floor strength and space for safe operation and hoist access.
Connect the power supply as specified and check functionality of height and backrest actuators before clinical use.
Adjust couch height using the electric controls to a safe working level for clinicians, minimising bending and manual handling strain.
Use the motorised backrest to position the patient appropriately for examination or treatment (supine, semi-recumbent, sitting or prone with breathing hole).
Apply and adjust accessories such as arms, cotsides or divided legs if fitted, ensuring they are securely locked before use.
Ensure retractable castors are set so that the couch is stable before the patient mounts the couch; engage castors for moving and disengage for treatment.
Observe the maximum safe working load of 320 kg and do not exceed this limit.
Clean the vinyl upholstery and frame between patients using suitable healthcare-approved cleaning agents compatible with anti-microbial vinyl; avoid harsh solvents or abrasive cleaners.
Periodically inspect the couch for signs of wear, damage to upholstery, loose fixings, or actuator issues and arrange servicing or repair according to the manufacturer’s maintenance schedule.
In the event of power failure, follow local procedures for safely lowering or repositioning the couch using any back-up features supplied (e.g. optional battery back-up if fitted).
Contraindications
Use with patients whose weight exceeds the stated safe working load and lift capacity of 320 kg.
Use in environments where the floor cannot safely support the combined weight of the couch and maximum patient load.
Use with damaged or heavily worn upholstery, frame or actuators that may compromise patient or clinician safety.
Use in explosive or highly flammable atmospheres or where the electrical classification requirements exceed the couch’s ratings.
Improper use as a lifting platform for equipment or as a step or seat for multiple individuals.
Adverse Effects
Potential risk of patient or staff injury if the couch is used beyond its safe working load or if brakes/castors are not correctly set before mounting or dismounting.
Risk of entrapment or pinch injury around moving parts (e.g. during height or backrest adjustment) if used without due care.
Possible discomfort or pressure issues for patients if used for very prolonged periods without appropriate pressure-relieving accessories.
Electrical hazard risk if the power cable or actuators are damaged and not inspected or serviced as recommended.
Storage Conditions
Designed for continuous use in clinical areas; when not in use, leave in a safe parked position with castors locked and height lowered if appropriate.
Operate and store in a dry indoor environment away from excessive moisture and extreme temperatures.
Avoid prolonged, direct exposure to strong sunlight on upholstery to reduce fading and material degradation.
Ensure power cable is routed to avoid trip hazards and is not crushed under wheels or furniture.
If the couch is taken out of service for storage, disconnect from mains power, cover to protect from dust, and store in a dry, secure area.