Plexr Plus Wireless Handpieces (Set of 3)
Plexr Plus
Medical device accessoriesPlasma soft-surgery device handpieces
Certifications
- The Plexr system (including its handpieces) is described as an EU Certified Class IIb medical device for dermatological and plastic microsurgery applications, with CE certificate for medical devices (e.g. certificate number 16984/MDD referenced in independent clinical summaries).
- Plexr Plus handpieces form part of the CE Marked Plexr Plus system manufactured by GMV srl in Italy, which is distributed in multiple countries and supported by numerous peer Reviewed publications.
- Plexr Plus has been used as a predicate device in at least one FDA 510(k) submission for similar plasma Based technologies, indicating recognised regulatory status for the overall system (K210693 references Plexr Plus as predicate), although the handpieces themselves are not separately cleared.
- The Plexr system (including its handpieces) is described as an EU Certified Class IIb medical device for dermatological and plastic microsurgery applications, with CE certificate for medical devices (e.g. certificate number 16984/MDD referenced in independent clinical summaries).
- Plexr Plus handpieces form part of the CE Marked Plexr Plus system manufactured by GMV srl in Italy, which is distributed in multiple countries and supported by numerous peer Reviewed publications.
- Plexr Plus has been used as a predicate device in at least one FDA 510(k) submission for similar plasma Based technologies, indicating recognised regulatory status for the overall system (K210693 references Plexr Plus as predicate), although the handpieces themselves are not separately cleared.
Plasma soft-surgery device handpieces
Description
The Plexr Plus wireless handpieces are the dedicated plasma output applicators for the Plexr Plus soft-surgery system. A full Plexr Plus configuration consists of three independent, cordless handpieces, each with a different fixed power and frequency setting (typically identified as low, medium and high power, white/green/red) to allow tailored treatments for a wide range of dermatological and aesthetic indications. The used Plexr Plus listing referenced specifies that the unit’s accessories include three fully working wireless handpieces, enabling full multi-handpiece operation of the device.
Bnefits
- Set of three independent wireless handpieces, each optimised with a different fixed power and frequency for specific treatment depths and indications.
- Cordless, cable-free operation improves ergonomics and access around delicate areas such as eyelids and peri-ocular skin.
- All handpieces connect to the main Plexr Plus base unit wirelessly (via proprietary radio/Wi-Fi link), eliminating the need for signal cables during treatment.
- Handpieces are recharged by placing them on the electromagnetic induction charging/docking station of the Plexr Plus system, supporting several hours of continuous use per charge.
- Multiple handpieces allow three simultaneous active workstations from a single Plexr Plus device, increasing workflow efficiency in multi-room clinics.
- Factory-calibrated handpieces with microprocessor-controlled output provide consistent plasma arcs and precise energy delivery.
- Designed specifically for non-surgical, contact-free plasma treatments ("plasma soft surgery") such as eyelid lifting, wrinkle reduction and benign lesion removal.
Indications
- Accessories for the Plexr Plus plasma soft-surgery device, used in aesthetic medicine, dermatology, ophthalmology, dentistry and gynaecology when connected to a compatible Plexr Plus base unit.
- Non-surgical blepharoplasty (eyelid lifting) and tightening of peri-ocular skin when used with appropriate Plexr Plus settings and single-use tips.
- Treatment of fine lines and wrinkles, acne scars, superficial benign skin lesions and other soft-surgery indications as per the Plexr Plus device’s IFU and clinical protocols.
- Use by trained medical professionals as part of a CE-certified Plexr Plus system; not intended as stand-alone treatment devices without the main base unit.
Composition
- Three ergonomic cordless handpieces designed for the Plexr Plus system (typically low/medium/high power variants).
- Each handpiece contains: internal electronics and microprocessor-controlled plasma generator board, integrated rechargeable lithium (or lithium-polymer) battery pack, RF/Wi-Fi communication module, LED indicator(s) and tip connector assembly.
- Outer housing: hard, medical-grade plastic body (colour-coded, commonly white/green/red for low/medium/high power variants).
- Single-use sterile tips (not always included with used-equipment accessory bundles) are separate consumables and attach to the front of the handpieces.
Formulation
- Non-sterile, reusable electrical handpieces for use exclusively with the Plexr Plus base/charging station and approved disposable tips.
- Each handpiece has a fixed power and frequency configuration corresponding to different treatment intensities and tissue effects.
- Cordless design with internal battery, wirelessly linked to the Plexr Plus main unit for control and monitoring.
Packaging
- Typical new system configuration: three wireless handpieces supplied with a Plexr Plus base/charging station and accessories (in a dedicated device case or crate).
- In the referenced used-equipment listing, the accessory bundle is described as "comes with 3 fully working wireless handpieces"; additional original packaging or consumables may not be included and should be confirmed with the seller.
- Handpieces are usually supplied with protective foams or trays to prevent impact damage during transport.
Usage
- Use only with a compatible Plexr Plus base unit and in accordance with the official Plexr Plus instructions for use (IFU).
- Before first use each day, ensure all three wireless handpieces are fully charged by placing them on the Plexr Plus docking/charging station until the charge indicators confirm adequate battery level.
- Pair or confirm wireless connection between the handpieces and the Plexr Plus base (this is normally automatic on power-up according to manufacturer software).
- Fit a new, single-use sterile tip to the selected handpiece according to the procedure being performed, ensuring it is fully seated and locked in place.
- Select the appropriate handpiece (low/white, medium/green or high/red) and device settings based on the indication, treatment area and patient skin type, following established Plexr Plus protocols.
- During treatment, hold the handpiece as instructed, maintaining the recommended distance from the skin so that the plasma arc forms correctly between the tip and the epidermis.
- After each treatment, safely dispose of the single-use tip according to clinical sharps and biohazard waste regulations; wipe the external surface of the handpiece with an approved disinfectant wipe without immersing it in liquid.
- Return handpieces to the docking station between patients or at the end of the session to maintain charge; do not attempt unauthorised repairs or battery replacement.
- Used-equipment buyers should have handpieces inspected, serviced and, if necessary, re-validated by an authorised Plexr service provider before clinical use.
Contraindications
- Do not use the handpieces without a functioning, compatible Plexr Plus base unit and approved single-use tips.
- Not for use by untrained personnel or for self-treatment; Plexr Plus procedures should be performed only by appropriately trained medical professionals.
- Do not use handpieces that are visibly damaged, cracked, have loose components, or show signs of fluid ingress.
- Do not use in environments where flammable anaesthetics or gases are present, in accordance with general electro-surgical/plasma device safety guidance.
- If the Plexr Plus device is not indicated for particular patient conditions (e.g. certain pacemaker/implant situations, uncontrolled systemic disease, pregnancy, etc.), then the handpieces must not be used on such patients.
Adverse Effects
- No intrinsic adverse effects are associated with the handpieces as hardware; possible complications relate to Plexr Plus plasma procedures themselves (e.g. transient erythema, oedema, crusting, discomfort in treated skin).
- Improper use, incorrect power selection or poor technique may increase the risk of burns, pigmentary changes, scarring or delayed healing in the treatment area.
- Electrical malfunction, though uncommon, could lead to device shutdown or inconsistent plasma output; equipment should be serviced according to manufacturer recommendations.
Storage Conditions
- Store handpieces in a clean, dry environment, ideally in the original device case or docking station when not in use.
- Avoid exposure to excessive heat, direct sunlight, or high humidity which could damage electronic components and battery performance.
- Do not store handpieces with heavy objects on top or in a way that could stress or deform the casing or tip connector.
- For longer periods of non-use, follow manufacturer guidance for lithium battery storage (e.g. partial charge, periodic recharging) to maintain battery health.
Duration
Not directly applicable, as the accessories themselves are handpieces for the Plexr Plus device. Typical individual Plexr Plus treatment sessions last from several minutes up to around 45\u201360 minutes depending on indication and treatment area, as determined by the treating clinician.
Onset
Not directly applicable to the accessories themselves. When used with the Plexr Plus system, many plasma soft-surgery treatments show immediate tissue retraction and visible tightening, with ongoing collagen-stimulating effects over several weeks.