Refurbished Alma Soprano ICE Platinum Handpiece
Alma Lasers
Aesthetic Laser EquipmentDiode laser hair removal handpiece
Certifications
- The Alma Soprano ICE Platinum platform (including its applicators) is marketed as a CE Marked medical laser system under the EU Medical Devices Directive / MDR in relevant territories.
- Alma Lasers operates certified quality management systems (e.g. ISO 9001 and ISO 13485) for the design, manufacture and inspection of medical laser devices.
- The Soprano ICE Platinum system has FDA clearance for hair removal indications in the United States; the refurbished handpiece is an original component intended for use with that cleared system.
- Refurbishment of the handpiece is provided by third Party service providers; any additional warranties or test certifications would be specific to the refurbisher and not the original manufacturer.
- The Alma Soprano ICE Platinum platform (including its applicators) is marketed as a CE Marked medical laser system under the EU Medical Devices Directive / MDR in relevant territories.
- Alma Lasers operates certified quality management systems (e.g. ISO 9001 and ISO 13485) for the design, manufacture and inspection of medical laser devices.
- The Soprano ICE Platinum system has FDA clearance for hair removal indications in the United States; the refurbished handpiece is an original component intended for use with that cleared system.
- Refurbishment of the handpiece is provided by third Party service providers; any additional warranties or test certifications would be specific to the refurbisher and not the original manufacturer.
Diode laser hair removal handpiece
Description
This refurbished Alma Soprano ICE Platinum handpiece is a pre-owned diode laser applicator designed for use with the Alma Soprano ICE Platinum hair removal platform. The Platinum Trio-style handpiece integrates three wavelengths (755 nm Alexandrite, 810 nm diode and 1064 nm Nd:YAG) in a single applicator and uses Alma’s ICE contact-cooling technology to deliver comfortable, virtually painless hair removal for all skin types. According to the seller listing, the handpiece has delivered approximately 3,808,466 shots since it was refurbished and is being sold without any warranty or guarantee. It is intended as a replacement or additional handpiece for clinics already operating a compatible Alma Soprano ICE Platinum system and must be installed and used in accordance with Alma’s original instructions for use.
Bnefits
- Refurbished original Alma Soprano ICE Platinum handpiece, offering significant cost savings versus purchasing a new applicator.
- Trio clustered diode technology combining 755 nm, 810 nm and 1064 nm wavelengths in a single handpiece to target different follicle depths and hair types.
- ICE contact-cooling technology at the sapphire tip helps maintain epidermal protection and patient comfort during treatment.
- Supports SHR (Super Hair Removal) in-motion technique for fast, virtually painless hair removal on all skin types, including tanned skin, when used with the compatible console.
- Designed for high-volume clinical use; the handpiece on offer has an indicated shot count of around 3.8 million since refurbishment, with typical diode stack life ratings in the multi-million pulse range.
- Allows clinics with an existing Soprano ICE Platinum platform to replace a failing handpiece or add a backup applicator without purchasing a full new system.
Indications
- Use as a replacement or additional hair removal handpiece on an existing Alma Soprano ICE Platinum laser platform.
- Permanent hair reduction and long-term hair removal on all Fitzpatrick skin types (I–VI) when used with the Soprano ICE Platinum system under appropriate clinical protocols.
- Treatment of unwanted hair on face and body in professional medical-aesthetic clinics and dermatology practices with a compatible Alma console.
Composition
- Integrated diode laser stack capable of emitting 3 combined wavelengths: 755 nm (Alexandrite), 810 nm (diode) and 1064 nm (Nd:YAG), housed in the applicator head.
- Sapphire or equivalent optical contact-cooling window at the treatment tip with integrated ICE cooling module.
- Ergonomic plastic/metal handpiece housing with trigger control, status indicators and cable strain relief.
- Multi-core umbilical cable assembly containing power, control and cooling lines connecting the handpiece to the Alma Soprano ICE Platinum console.
- Internal temperature and performance monitoring components designed by Alma Lasers as part of the original device architecture.
Formulation
- Refurbished multi-wavelength diode laser handpiece designed exclusively for the Alma Soprano ICE Platinum platform.
- Tri-wavelength (755/810/1064 nm) SHR hair removal applicator with integrated ICE contact cooling.
- Electronic shot counter integrated via the host system; listing specifies approximately 3,808,466 shots delivered since refurbishment.
- Intended for professional use only, by trained operators, according to Alma’s original operating manual.
Packaging
- Supplied as a single refurbished handpiece, typically shipped in a protective hard case with foam insert to stabilise the applicator and cable during transport.
- No additional accessories or console included; listing is for the handpiece only.
- Sold as a used/refurbished component with no manufacturer or seller guarantee stated in the listing.
Usage
- Ensure compatibility with an existing Alma Soprano ICE Platinum console before purchase and installation; installation and setup should be performed by a suitably qualified engineer or Alma-trained technician.
- Before connecting the refurbished handpiece, power down and isolate the laser system according to the manufacturer’s safety procedures.
- Connect the umbilical cable and any cooling couplers to the appropriate ports on the Soprano ICE Platinum unit, ensuring secure mechanical and electrical connections.
- Prime and check the cooling system if required by the console instructions, verifying adequate flow and correct ICE tip temperature before clinical use.
- On first power-up, perform system self-tests and calibration steps as described in Alma’s user manual and confirm that the console recognises the handpiece and reports acceptable output and temperature values.
- Operate the handpiece strictly according to Alma’s treatment protocols for Soprano ICE Platinum, selecting suitable parameters (fluence, pulse duration, repetition rate and mode) for the patient’s skin type, hair type and treatment area.
- Continuously move the handpiece in the recommended in-motion pattern when using SHR mode, ensuring adequate contact and cooling at the treatment tip.
- Monitor the handpiece for any warning messages from the console (e.g. over-temperature, cooling failure, shot count limits) and discontinue use immediately if such errors occur.
- After each patient, clean and disinfect the tip and external handpiece surfaces with compatible non-corrosive agents, following Alma’s IFU and local infection prevention guidelines.
- Periodically inspect the handpiece for cable damage, cracks in the housing, clouding or pitting of the window and degradation of cooling performance; remove from service and arrange professional servicing if faults are detected.
Contraindications
- Do not use the handpiece with any laser platform other than a compatible Alma Soprano ICE Platinum system.
- Do not operate the handpiece if there is visible damage to the housing, cable, window or connectors, or if the console reports cooling or calibration errors.
- Use of a refurbished handpiece without appropriate safety checks, performance verification and maintenance by a qualified engineer is contraindicated.
- Not intended for home use or operation by untrained personnel; professional clinical setting and trained operators are required.
- All patient-level contraindications for laser hair removal (e.g. certain photosensitive conditions, pregnancy, active infections or lesions in the treatment area) remain governed by the Alma Soprano ICE Platinum system’s IFU and clinical protocols.
Adverse Effects
- If used outside of manufacturer guidelines or with inadequate cooling, there is a risk of burns, blistering, pigmentary changes or scarring in treated skin.
- Malfunction or degradation of a refurbished handpiece (e.g. uneven output, faulty cooling) may increase the risk of ineffective treatment or local tissue injury if not detected through routine checks.
- Electrical or cooling system faults could potentially damage the host laser console or cause system shutdown if connections are not secure or if leaks occur.
- Standard laser safety risks apply, including potential eye injury if appropriate protective eyewear and safety measures are not strictly followed in the treatment room.
Storage Conditions
- Store the handpiece in a clean, dry environment, ideally in a padded case to protect against shocks, dust and accidental impacts when not in use.
- Avoid exposure to extremes of temperature, high humidity or direct sunlight that could damage optical or electronic components.
- Ensure that any residual cooling water in the system is managed according to the console manufacturer’s recommendations to prevent internal corrosion or freezing.
- Do not place heavy objects on top of the handpiece or its cable and avoid kinking or sharply bending the umbilical.
- When storing for extended periods, follow Alma’s guidance for powering down and securing the associated Soprano ICE Platinum console and accessories.