Footswitch for Electric Plinth/Chair

Footswitch for Electric Plinth/Chair

Plinth Medical

Medical furniture accessory
  • Plinth Medical electric couches with which this footswitch is used are classified as Class I medical devices under MDD 93/42/EEC and are specified to meet IEC/EN 60601 medical electrical standards and IPX4 ingress protection; the footswitch forms part of this certified system when supplied with the couch.
  • Manufactured in the UK by Plinth Medical Ltd, which states operation of quality management systems for design and production of medical couches and accessories.
Electric couch foot switch (2-button, single motor)

Description

The Footswitch for Electric Plinth/Chair is a Linak 2-button foot switch designed for single-motor Plinth Medical couches and chairs, supplied with a round DIN plug connector. Offered in place of the standard hand control, it allows effortless hands-free operation of electric height or Hi-Lo functions, so clinicians can adjust the couch or chair position using their feet while keeping their hands free for patient care. The robust, low-profile pedal unit sits on the floor near the couch base and connects directly to the Linak control system used on compatible Plinth Medical electric models.

Bnefits

  • Hands-free operation: replaces the standard hand control so the clinician can adjust couch height with their feet while keeping hands free for clinical tasks.
  • Improved workflow and ergonomics: easy access to height controls without having to reach for a handset, particularly useful during procedures.
  • Infection-control friendly: reduces the need to touch hand controls with gloved or contaminated hands, supporting good infection-prevention practice.
  • Dedicated 2-button layout: simple up/down (or equivalent) control for single-motor Linak-driven Plinth couches.
  • Engineered specifically for Plinth Medical single-motor couches and chairs with round DIN plug, ensuring correct electrical and mechanical compatibility.
  • Durable construction designed for frequent use in busy clinical environments.
  • Low-profile foot pedal reduces trip risk while remaining easy to locate and operate by touch.

Indications

  • Accessory for compatible single-motor Plinth Medical electric couches and treatment chairs requiring foot-operated height or Hi-Lo control.
  • Use in clinics, GP surgeries, outpatient departments, physiotherapy and podiatry suites, and other treatment rooms where Plinth Medical couches are installed.
  • Suitable where clinicians prefer or require foot operation of couch controls for ergonomic or infection-control reasons.

Composition

  • Two-pedal footswitch body (likely metal and high-impact plastic/thermoplastic housing, as per typical Linak foot control assemblies).
  • Integrated 2-button switch mechanism for single-motor control (up/down or equivalent).
  • Pre-fitted flexible cable terminated with a round multi-pin DIN plug compatible with the Linak actuator/control box on Plinth couches.
  • Non-slip underside or feet to help maintain position on the floor beside the couch.
  • Ingress-protected housing appropriate for clinical environments (specific IP rating not separately stated for the accessory, but couch systems are specified to medical electrical standards).

Formulation

  • Type: Linak Footswitch 1 – 2-button footswitch for single-motor Plinth couches (round DIN plug).
  • Plinth part number: LFS1.
  • Buttons: 2 (typically height up / height down or equivalent Hi-Lo function).
  • Connection: round DIN plug for Linak control system used on Plinth Medical electric couches and chairs.
  • Compatibility: single-motor Plinth couches and chairs listed by Plinth Medical as using Linak Footswitch 1 (e.g. selected podiatry, examination and treatment chairs).

Packaging

  • Supplied as a single 2-button footswitch assembly with attached cable and round DIN plug (one unit per pack).
  • Packed in a protective carton or box to prevent damage to the pedal housing and cable during transport.
  • Outer packaging labelled with Plinth Medical branding, product description (Footswitch for Electric Plinth/Chair), and part number (LFS1 / FS1 / Linak Footswitch 1).

Usage

  • Ensure the couch or chair is a compatible Plinth Medical single-motor electric model using a Linak control system and round DIN socket before connecting the footswitch.
  • Before installation, switch off and isolate the couch from the mains supply in accordance with local electrical safety procedures.
  • Locate the appropriate footswitch/handset port on the couch control box (round DIN socket) and plug in the footswitch connector, ensuring it is fully seated and secure.
  • Place the footswitch on the floor near the base of the couch or chair in a position that is easy for the operator to reach with their foot but does not create a trip hazard.
  • Restore power to the couch and briefly test both buttons to confirm correct operation of the height/Hi-Lo function before treating patients.
  • During use, operate the couch by pressing the appropriate pedal (e.g. one button for raising and the other for lowering the couch or chair), keeping feet clear of couch moving parts.
  • Do not place heavy objects on the footswitch and avoid pulling or twisting the cable; route the cable so that it is not under tension and does not present a tripping risk.
  • Periodically inspect the footswitch, cable and plug for signs of wear, damage or loose connections; remove from service and arrange repair or replacement if any faults are found.
  • Clean the external surfaces of the footswitch regularly with a manufacturer-approved detergent or disinfectant wipe, avoiding excessive moisture ingress and following both Plinth Medical cleaning guidance and local infection-control protocols.

Contraindications

  • Do not use with non-Plinth couches or with Plinth models that are not specified as compatible with Linak Footswitch 1 or that do not use a round DIN control plug.
  • Do not use the footswitch if the housing, cable or plug is visibly damaged, if the switch is intermittent, or if the couch does not respond correctly to button presses.
  • Not intended for use by patients; it is an operator control device for trained staff only.
  • Do not operate the couch via the footswitch in environments where liquid spills or floor contamination may pose electrical or slip hazards unless cleaned and dried appropriately.
  • Do not attempt to modify the plug, cable or internal wiring of the footswitch.

Adverse Effects

  • Incorrect positioning of the footswitch or cable may create a minor trip hazard for staff if not managed appropriately.
  • Unintended activation (e.g. accidental pressing of a pedal or object resting on the switch) could cause unwanted couch movement if the couch is powered and not supervised.
  • Using a damaged or incompatible footswitch may result in erratic couch operation or failure to move, which could disrupt procedures and require manual or service intervention.

Storage Conditions

  • When installed, the footswitch normally remains in use on the floor beside the couch; ensure it is kept on a dry, clean surface free from standing liquids.
  • If stored separately or as a spare part, keep in a clean, dry indoor environment away from excessive dust, moisture and corrosive substances.
  • Avoid placing heavy objects on the pedal housing or cable during storage to prevent mechanical damage.
  • Store and operate within typical indoor clinical temperature and humidity ranges, avoiding extreme heat, cold or prolonged direct sunlight.

Duration

Not applicable; this is a reusable control accessory intended for long-term use over the service life of the compatible couch or chair, subject to regular inspection and maintenance.

Onset

Immediate mechanical effect; couch or chair movement begins as soon as a pedal is pressed and stops when the pedal is released, according to the couch\u2019s control logic.