Gynae/ GP practice couch (Hydraulic)

Gynae/ GP practice couch (Hydraulic)

Plinth Medical

Furniture
  • CE marked as a Class I medical device under the Medical Devices Directive 93/42/EEC (as declared by manufacturer).
  • Upholstery in hardwearing, fire Retardant, anti Microbial vinyl meeting healthcare upholstery standards.
  • UK Manufactured medical furniture built to typical healthcare quality and safety requirements for examination couches.
Gynaecological examination couch (hydraulic)

Description

The Plinth Medical Gynae/ GP practice couch (Hydraulic), model 93P, is a traditional gynaecology and general practice couch featuring a tilting seat, chrome stirrups and stainless-steel tray to provide ideal patient comfort and positioning for gynaecological procedures in busy practices. UK manufactured and built around a robust hydraulic lift system, the couch offers a height range of approximately 52–101 cm, a length of 180 cm and width of 63 cm, with a safe working load of 250 kg. The multi-purpose design allows the couch to be used for both specialist gynaecological work and general examination, and with additional accessories it can serve as a competent operating or recovery table. It includes a breathing hole, retractable castors, hoist clearance of 130 mm and is upholstered in hardwearing, anti-microbial, fire-retardant vinyl over comfort foam. The couch is designed for long service life, with a lifetime frame and 5-year parts guarantee and a typical lifespan of around 16 years.

Bnefits

  • Traditional gynae design with tilting seat, stirrups and stainless tray for optimal positioning and access during gynaecological procedures.
  • Hydraulic height adjustment (approx. 52–101 cm) provides smooth, controlled lifting without dependence on mains electricity.
  • Multi-purpose configuration allows use as both a gynaecology chair and full-length examination couch for general practice.
  • High safe working load of 250 kg (approximately 39 stone) supports a wide range of patients and clinical scenarios.
  • Comfort foam construction and ergonomic design enhance patient comfort during examinations and procedures.
  • Hardwearing, anti-microbial, fire-retardant vinyl upholstery supports infection control and safety requirements.
  • Retractable castors and 130 mm hoist clearance provide mobility and compatibility with mobile hoists for safer patient transfers.
  • Breathing hole in the head section enables prone positioning when required for examinations or treatments.
  • UK-manufactured couch with lifetime frame guarantee and 5-year parts guarantee, designed for a typical 16-year lifespan, offering excellent long-term value.
  • Easy, low-cost operation with minimal ongoing running costs due to hydraulic mechanism and robust construction.

Indications

  • Gynaecological examinations and procedures in general practice, gynaecology clinics and outpatient settings.
  • Use as a general examination couch for a wide range of routine medical assessments.
  • Minor procedures and interventions that require tilt, lithotomy or stirrup positioning.
  • Recovery positioning and short-term post-procedure rest when used as a flat couch.
  • Clinical environments where a multi-purpose gynae/practice couch with hydraulic operation is preferred over electric models.

Composition

  • Steel frame with welded construction, designed for high strength and durability.
  • Hydraulic lifting mechanism providing manual, foot-operated height adjustment.
  • Padded comfort foam sections (head/back, seat and leg sections).
  • Upholstery in hardwearing, anti-microbial, fire-retardant vinyl (multiple colour options).
  • Chrome gynaecology stirrups for lithotomy positioning.
  • Removable stainless-steel debris tray beneath the seat section.
  • Retractable castor system for mobility and positioning in the clinic.
  • Frame design providing approximately 130 mm hoist clearance.
  • Breathing hole in the head section with removable plug.
  • Fixed couch base with adjustable foot to accommodate uneven floors.

Formulation

  • Overall length: approximately 180 cm (71 inches).
  • Overall width: approximately 63 cm (25 inches).
  • Height range: approximately 52–101 cm (20–40 inches) via hydraulic lift.
  • Safe working load: 250 kg (approx. 39 stone).
  • Hydraulic height adjustment (non-electric).
  • Tilting seat with pelvic cut-out for gynaecological access.
  • Hoist clearance: approximately 130 mm.
  • Breathing hole in head section for prone positioning.
  • Supplied with gynae stirrups and stainless tray as standard.

Packaging

  • Supplied as a single gynae/practice couch unit with hydraulic lift, stirrups and stainless tray.
  • Typically delivered fully assembled or largely assembled on a pallet or large-item carrier, with final positioning and minor assembly carried out on site.
  • Includes user/installation instructions, warranty information and upholstery colour details.
  • Bespoke, made-to-order configuration (colour and options) from manufacturer or distributor.

Usage

  • Install the couch on a level, stable floor surface capable of supporting the combined weight of the couch and maximum patient load.
  • Before first use, check all moving parts, hydraulic operation, stirrups, tray and castors for correct function and security.
  • Use foot-operated hydraulic control to raise or lower the couch smoothly to a safe working height before and during patient positioning.
  • Adjust the tilting seat and backrest (where provided) to achieve optimal positioning for gynaecological procedures or general examinations.
  • Position and secure the gynae stirrups to support the patient’s legs; ensure patient comfort and adequate support before commencing any procedure.
  • Slide the stainless-steel tray into position beneath the pelvic area when required and remove it for cleaning after use.
  • Use retractable castors to move the couch when necessary; ensure castors are locked and the couch is stable before patient mounting or any procedure.
  • Assist the patient on and off the couch, particularly when it is set at a higher examination height.
  • Clean the vinyl upholstery, stirrups, tray and frame between patients using approved disinfectants compatible with anti-microbial vinyl and metal surfaces.
  • Conduct periodic inspection and maintenance in line with Plinth Medical’s recommendations, including checking hydraulic operation, fasteners, castors and upholstery condition.

Contraindications

  • Do not use the couch with patients whose weight exceeds the stated safe working load of 250 kg.
  • Do not use if there is visible structural damage, instability, or malfunction of the hydraulic system, castors, stirrups or tray.
  • Avoid use in environments with floor conditions or space constraints that prevent safe couch positioning and hoist access.
  • Use specialist judgement when employing steep tilt or lithotomy positions in patients where such positioning may be clinically contraindicated (e.g., certain cardiovascular, respiratory or spinal conditions).

Adverse Effects

  • Potential discomfort or musculoskeletal strain for patients if positioning, tilt or stirrups are not adjusted correctly or if procedures are prolonged.
  • Risk of falls or slips when patients mount or dismount the couch, particularly at elevated heights, if not adequately assisted.
  • Risk of entrapment or minor pinch injuries around moving joints or mechanisms if limbs or objects are placed inappropriately during adjustment.
  • Risk of staff manual-handling injuries if the couch is moved or adjusted incorrectly or if hoist access is not used where appropriate.

Storage Conditions

  • Intended for permanent in-room installation; store and use indoors in a dry clinical environment.
  • Keep away from excessive moisture, corrosive substances and extreme temperatures that could damage hydraulic components, metalwork or upholstery.
  • Ensure adequate clearance around the couch for safe patient access, staff movement and hoist use.
  • Clean and disinfect upholstery and metal surfaces regularly; avoid harsh solvents or abrasives that could degrade the anti-microbial vinyl or finishes.
  • If the couch is unused for extended periods, keep it in a neutral flat position with hydraulic system depressurised as recommended by the manufacturer.

Duration

Not directly applicable; the couch is used for the duration of examinations or procedures, typically from a few minutes to around an hour depending on clinical need.

Onset

Not applicable; this is a medical furniture product used for patient positioning and support, with immediate functional benefit once adjusted.

Browse more Furniture