Plinth 2000 503OPH 3 Section Outpatient Couch Hydraulic
Plinth 2000
Medical furniture – 3-section outpatient examination and treatment couch (Class I medical device)Hydraulic 3-section outpatient couch with mobility base (Model 503OPH)
Certifications
- CE Marked Class I medical device in conformity with EC Directive MDD 93/42/EEC Annex IX Class I, according to manufacturer datasheet for the 3 Section outpatient couch series.
- Ingress protection rating IPx4 for the 503OP series as specified in the technical datasheet.
- Electrical safety and performance standards for the series given as IEC 601 Part 1 and EN 60601 for medical electrical equipment (relevant to electric variants in the same family).
- Vinyl upholstery flame Retardant to BS 5852 Ignition Source 5 – CRIB 5 (BS 7176) for medium hazard application environments.
- Foam padding tested to BS 5852: Part 2: 1982, Ignition Source 5 (CRIB 5) for fire behaviour.
- Upholstery vinyl independently tested for resistance to spread of MRSA, E. coli and similar bacteria and fungi, with an abrasion resistance rating of 500,000 Martindale rubs.
- Plinth Medical Ltd described as externally audited to ISO 9001:2015 quality management standard by LRQA in manufacturer documentation.
- Plinth Medical literature states typical product lifespan of approximately 16 years for couches manufactured under their quality system.
- Medisave UK Ltd, as distributor, operates ISO 9001 quality management and ISO 14001 environmental management systems and holds MHRA Wholesale Dealer Authorisation (WDA) Licence 18935, as per company information pages (organisational certifications, not device Specific CE marking).
- CE Marked Class I medical device in conformity with EC Directive MDD 93/42/EEC Annex IX Class I, according to manufacturer datasheet for the 3 Section outpatient couch series.
- Ingress protection rating IPx4 for the 503OP series as specified in the technical datasheet.
- Electrical safety and performance standards for the series given as IEC 601 Part 1 and EN 60601 for medical electrical equipment (relevant to electric variants in the same family).
- Vinyl upholstery flame Retardant to BS 5852 Ignition Source 5 – CRIB 5 (BS 7176) for medium hazard application environments.
- Foam padding tested to BS 5852: Part 2: 1982, Ignition Source 5 (CRIB 5) for fire behaviour.
- Upholstery vinyl independently tested for resistance to spread of MRSA, E. coli and similar bacteria and fungi, with an abrasion resistance rating of 500,000 Martindale rubs.
- Plinth Medical Ltd described as externally audited to ISO 9001:2015 quality management standard by LRQA in manufacturer documentation.
- Plinth Medical literature states typical product lifespan of approximately 16 years for couches manufactured under their quality system.
- Medisave UK Ltd, as distributor, operates ISO 9001 quality management and ISO 14001 environmental management systems and holds MHRA Wholesale Dealer Authorisation (WDA) Licence 18935, as per company information pages (organisational certifications, not device Specific CE marking).
Hydraulic 3-section outpatient couch with mobility base (Model 503OPH)
Description
The Plinth 2000 503OPH is a hydraulic, 3-section outpatient couch designed for examination, treatment and safe movement of patients within hospital departments and clinics. It incorporates fold-down side support rails, a large wheel base with central braking and steering for controlled patient transport, and adjustable backrest and foot sections to position patients in a variety of sitting and lying postures. The couch has a safe working load and lifting capacity of 250 kg, uses comfort foam with hardwearing anti-microbial vinyl upholstery, and is manufactured in the UK by Plinth Medical/Plinth 2000. It is commonly used in Accident & Emergency, antenatal and ENT departments, as well as GP surgeries and other outpatient areas.
Bnefits
- Robust 3-section outpatient couch intended for examination, treatment and intra-departmental patient movement.
- Hydraulic height adjustment (503OPH variant) with adjustable backrest and foot section to support patients in a range of sitting and lying positions.
- Large wheel system with steering facility and central braking to assist safe and controlled transport of patients within the clinic or hospital.
- Fold-down side support rails to enhance patient security during transfer and when the couch is in use.
- Safe working load and lifting capacity of 250 kg (approximately 550 lb / 39 stone), suitable for a wide range of adult patients.
- Comfort foam padding and hardwearing anti-microbial vinyl upholstery to support patient comfort and infection control.
- Vinyl upholstery is phthalate free, flame-retardant to CRIB 5 (BS 7176), independently tested to reduce spread of MRSA, E. coli and similar organisms, and rated to 500,000 Martindale rubs for heavy-duty use.
- Foam padding meeting BS 5852: Part 2: 1982, Ignition Source 5 (CRIB 5) fire safety requirements.
- UK-manufactured couch with lifetime frame guarantee, 5-year parts guarantee and an indicative product lifespan of approximately 16 years.
- Hoist clearance of about 130 mm beneath the frame to accommodate most mobile hoists.
- Supplied with paper roll holder and fold-down cot sides as standard for routine outpatient procedures.
- Height range (approximately 50–98 cm) designed to aid both patient access and ergonomically safe working positions for clinicians.
- CE-marked as a Class I medical device with technical standards including IPx4 ingress protection and compliance with IEC 601 Part 1 / EN 60601 for medical electrical equipment (relevant to series operational standards).
Indications
- Use as a general-purpose outpatient couch for physical examination and treatment of patients in hospital departments and clinics.
- Patient positioning for a variety of procedures using adjustable backrest and foot sections in sitting or lying configurations.
- Short-distance transport and transfer of patients within the clinic or department using the large wheel base and steering facility.
- Deployment in Accident & Emergency departments for assessment, treatment and short-term recovery of patients.
- Use in antenatal and maternity clinics for examinations and routine procedures requiring adjustable positioning.
- Use in ENT, GP surgeries and other outpatient and treatment areas requiring a versatile 3-section couch with hydraulic height adjustment.
Composition
- Steel-framed 3-section outpatient couch (exact steel grade not publicly listed) with integrated mobility wheel base on the 503OP series.
- Upholstery vinyl described by the manufacturer as phthalate-free PVC with textile backing, total thickness around 1.10 mm and weight approximately 705 g/m² (values from Plinth upholstery specification, not product-specific label).
- Vinyl upholstery rated flame-retardant to BS 5852 Ignition Source 5 – CRIB 5 (BS 7176) for medium hazard environments.
- Vinyl independently tested to confirm effectiveness at reducing spread of MRSA, E. coli and similar bacteria and fungi, and rated to 500,000 Martindale rubs without damage to the top layer.
- Foam padding meeting BS 5852: Part 2: 1982, Ignition Source 5 (CRIB 5) fire safety performance.
- 125 mm twin-wheel castors as part of the base, with central braking system and directional lock as stated in manufacturer datasheet.
- Side support (cot) rails fitted to the couch structure for patient safety and security.
- Paper roll holder fitted as standard at the head end of the couch.
- Hydraulic height mechanism providing vertical adjustment of the couch; detailed internal component materials are not publicly listed.
- Electrical and control components are not fitted to the 503OPH hydraulic variant (electric components described separately in series documentation; exact component list is not publicly listed).
Formulation
- Three-section couch layout comprising backrest section, central seat section and foot section, intended for outpatient examination and treatment.
- Adjustable angle backrest for supporting the patient in a sitting position, with positive and negative angle adjustment (datasheet for 3-section models cites typical range approx. -20° to +85°).
- Adjustable foot section with similar positive and negative angle range (approx. -20° to +85°) to support lower limbs in various positions.
- Hydraulic height adjustment on the 503OPH model, providing a height range of approximately 50–98 cm (20–39 inches) as specified in manufacturer and distributor documentation.
- Large wheel system with steering facility and central braking, designed to allow easy movement of the couch with a patient on board and secure parking when stationary.
- Fold-down side support rails designed to be raised for patient safety during transfer and lowered to facilitate access.
- Comfort foam upholstery over the three couch sections, intended to provide comfort and support during examination or treatment.
- Anti-microbial vinyl upholstery offered in a range of colours (e.g. Almond, Atlantic Blue, Battleship, Candy, Citrus Green, Cobalt, Cocoa, Cool Blue, Denim, Gingersnap, Grape, Jasmine, Lupin, Marigold, Mulled Wine, Pillarbox Red, Rainforest, Sapphire Blue, Wasabi and others).
- Safe working load and lifting capacity of 250 kg (approximately 550 lb / 39 stone) as stated in the 503OP series datasheet.
- Hoist clearance approximately 130 mm beneath the frame to allow insertion of mobile hoists.
- IP rating of IPx4 for the 503OP series as documented in the manufacturer’s technical datasheet.
- Medical device classification: MDD 93/42/EEC Annex IX Class I, CE-marked according to the manufacturer’s datasheet for 3-section outpatient couches.
- Lifetime frame guarantee and 5-year guarantee on components, excluding upholstery, as defined in Plinth Medical product literature.
Packaging
- Manufacturer states that couches and chairs are delivered within UK mainland in approximately 7–10 working days by specialist delivery partners who move the product to the required room and unpack it at point of use.
- Option for removal and disposal of an old couch can be arranged at the time of ordering for an additional fee (per Plinth Medical general delivery information).
- Specific packaging materials, crate type, and protective wrapping used during transit are not publicly listed.
Usage
- Use the couch for examination, treatment and patient movement strictly in accordance with the manufacturer’s instructions and local clinical protocols.
- Adjust the backrest and foot section to the desired angle using the provided levers or controls, ensuring the patient is supported in a safe and comfortable sitting or lying position.
- Operate the hydraulic height mechanism to raise or lower the couch to a suitable working height while ensuring that hands, clothing and equipment are kept clear of moving parts.
- Always apply the central braking system when the couch is in use or when patients are getting on or off, and use the steering facility only when moving the couch within the department.
- Ensure fold-down side support rails are raised and securely positioned when transporting patients or when additional side protection is required, and lowered to permit safe access or transfer when appropriate.
- Do not exceed the stated safe working load and lifting capacity of 250 kg when positioning or transporting patients on the couch.
- Follow service manual recommendations that products should receive regular servicing; electrically operated products or couches subjected to heavy use are recommended to be serviced at least every 6 months, with other products serviced at least annually.
- Clean and decontaminate the couch in line with manufacturer guidance and local infection control policies; avoid strong alkalis or aggressive organic solvents that may damage vinyl or painted surfaces.
- Use couch roll or suitable protective covers over the vinyl upholstery where there is contact with bare skin or potential contamination, as recommended by the manufacturer.
- Carry out routine checks for upholstery damage, loose fixings or other signs of wear, and arrange repair or replacement via approved service routes if issues are identified.
- Refer to the official Plinth 2000 503OP Series service manual and the 503OP/503OPH datasheet for detailed operating instructions, maintenance schedules, warnings and safety information.
Contraindications
- Not publicly listed
Adverse Effects
- Not publicly listed
Storage Conditions
- Not publicly listed
Duration
Not publicly listed
Onset