Description
The Plinth 2000 Divided Leg 90 Degree Drop Chair (model 93CD) is a single-motor electric podiatry and treatment chair with a full 90° leg drop and a shorter seat section for unrivalled patient comfort and access. Designed on a twin-lift frame, it combines electric height adjustment with smooth gas-spring operated backrest and divided, extending leg rests. The chair converts quickly between couch and chair positions, allowing multi-disciplinary use in podiatry, chiropody and general treatment rooms. It features swing-back moulded armrests with level adjustment, a safe lifting capacity of up to 225 kg (35 stone), hoist clearance of 13 cm, robust retractable castors, and fully washable, fire-retardant Ambla vinyl upholstery available in a wide range of colours. The chair can go fully horizontal for patient recovery in emergencies and is CE marked under MDD 93/42/EEC Annex IX Class I.
Bnefits
- Divided and extending leg design with full 90° leg drop provides excellent access to the feet and lower legs.
- Shorter seat section and chair-style geometry offer improved ergonomics and comfort for podiatry and chiropody treatments.
- Electric height adjustment (single motor) reduces manual handling demands on clinicians.
- Gas-spring operated backrest and footrest enable smooth, precise positioning.
- Able to lift up to 225 kg (35 stone) from its lowest height, supporting a wide range of patients safely.
- Leg section adjustable from approximately -90° to +25° and backrest from -20° to +85°, giving wide positioning flexibility.
- Comfortable moulded swing-back arms with level adjustment improve patient support and can be moved out of the way for transfers.
- Hoist clearance of 13 cm (5") allows access for many mobile hoists, enhancing patient transfer safety.
- Fully washable, fire-retardant Ambla vinyl with antimicrobial properties supports infection control and durability.
- Robust retractable castors provide excellent mobility and stability when locked.
- Twin lift frame design increases strength, stability and long-term reliability.
- Chair can be set horizontal to act as a couch for patient recovery in emergency situations.
- Low running costs, UK manufacture, lifetime frame guarantee and multi-year parts guarantee provide strong long-term value.
Indications
- Podiatry and chiropody treatments requiring optimal access to feet and lower limbs.
- General outpatient and multidisciplinary clinics needing a combined treatment chair and couch.
- Minor procedures on the lower limbs performed in seated or semi-reclined positions.
- Use in shared treatment rooms where swing-back arms and flexible positioning are needed for different specialties.
- Environments requiring electric height adjustment, hoist access and high working load capacity for safe patient handling.
Composition
- Heavy-duty twin-lift steel frame designed for a lifting capacity of up to 225 kg.
- Three-section upholstered top comprising backrest, seat and divided leg sections.
- Comfort foam padding for all patient contact surfaces.
- Fully washable, fire-retardant Ambla vinyl upholstery with antimicrobial additive.
- Electric actuator for height adjustment (single-motor system).
- Gas struts for backrest and footrest angle adjustment.
- Moulded swing-back armrests with level adjustment.
- Retractable castors for mobility and base design with 13 cm hoist clearance.
- Adjustable foot at the base to compensate for uneven floors.
Packaging
- Supplied as a complete Plinth 2000 Divided Leg 90 Degree Drop Chair (model 93CD), typically delivered fully assembled or largely assembled on a pallet by specialist courier.
- Standard configuration includes electric height adjustment, gas-spring backrest and divided leg rests, moulded swing-back armrests, retractable castors, and adjustable foot.
- Upholstered in healthcare-grade Ambla vinyl in the selected colour from the Plinth Medical range.
- Accompanied by user instructions, warranty information and details of optional accessories (e.g. footswitch, breathing hole and plug, motorised backrest, paper roll holder, operators chair, double-thickness padding).
Usage
- Install the chair on a firm, level surface; use the adjustable foot to correct for minor floor unevenness and ensure stability.
- Connect the power cable to a suitable mains outlet as specified in the manufacturer’s instructions and confirm correct operation of the electric height adjustment before first use.
- Use the hand switch (standard) or optional footswitch to raise or lower the chair between approximately 46 cm and 95 cm to achieve a safe working height for the clinician.
- Adjust the backrest and divided leg sections using the gas-spring mechanisms to set the desired angles (backrest between about -20° and +85°, leg section between -90° and +25°).
- Swing the moulded armrests back or remove them as needed to facilitate patient transfers or to provide side access, then return and level-adjust them for patient comfort during treatment.
- When using a hoist, take advantage of the 13 cm hoist clearance under the frame and follow local manual handling and hoist manufacturer guidelines.
- Ensure retractable castors are in the locked position when the chair is in use and only released when moving the chair.
- For emergency situations or patient recovery, adjust the chair to a horizontal couch position as recommended by clinical protocols.
- Clean all vinyl surfaces and hand-contact areas between patients with suitable healthcare-approved detergents/disinfectants that are compatible with Ambla vinyl; avoid solvents or abrasive cleaners.
- Perform regular visual and functional checks of the frame, upholstery, electrics, gas struts and castors; arrange servicing or repair via Plinth Medical or an authorised service agent if any issues are found.
Contraindications
- Do not use with patients whose weight exceeds the stated lifting capacity of 225 kg (35 stone).
- Do not operate the chair if there is visible damage to the frame, upholstery, electric actuator, gas struts, castors or control handset.
- Not suitable for use in environments that exceed the electrical or environmental specifications in the manufacturer’s instructions (e.g. certain high-risk or wet areas) unless explicitly approved.
- Use caution with patients who have impaired balance, mobility or conditions where rapid positional changes (e.g. large backrest or leg adjustments) could cause dizziness or instability; adjust positions gradually and under supervision.
- Ensure appropriate clinical judgement regarding leg and backrest positions for patients with specific musculoskeletal or cardiovascular limitations.
Adverse Effects
- Improper locking of castors or incorrect positioning may lead to unintended chair movement, increasing the risk of falls or injury.
- Exceeding the weight capacity or using the chair when damaged can result in mechanical failure or instability.
- Inadequate cleaning may compromise infection control and contribute to cross-contamination between patients.
- Prolonged sitting or lying without appropriate repositioning or pressure care may contribute to discomfort or pressure-related skin problems in high-risk patients.
Storage Conditions
- Keep installed in a dry, indoor clinical environment away from direct water spray and excessive humidity.
- Avoid prolonged exposure of upholstery to direct sunlight or heat sources that could cause fading, cracking or degradation of the vinyl.
- Disconnect from the mains supply if the chair will not be used for an extended period and ensure the power cable is routed to prevent tripping or mechanical damage.
- Do not store heavy objects on the chair surface or use it as general storage when not in clinical use.
- Keep the area around the base free of obstructions to preserve hoist access and avoid damage to castors and frame components.
Duration
Not defined by the device; the chair is intended to support patients for the duration of podiatry or treatment sessions as determined by clinical requirements.
Onset