Replacement 3.5 V Rechargeable Battery for 71000 A 71000 C

Replacement 3.5 V Rechargeable Battery for 71000 A 71000 C

Welch Allyn

Diagnostic Equipment & Accessories
  • Supplied as a component for use within regulated Welch Allyn diagnostic systems; regulatory conformity (e.g. CE/UKCA, IEC 60601 Series electrical safety) is assessed at the device/handle level.
  • Nickel–cadmium rechargeable battery subject to applicable transport and hazardous materials regulations; users should follow local rules for handling and disposal of NiCd batteries.
Rechargeable power-handle battery

Description

The Replacement 3.5 V Rechargeable Battery for 71000-A / 71000-C (Welch Allyn part 72300) is a nickel–cadmium (NiCd) rechargeable battery designed specifically for Welch Allyn 3.5 V wall and direct plug-in power handles. It is the OEM-style battery used in Welch Allyn 71000-A and 71000-C rechargeable handles (and other compatible 3.5 V rechargeable handles), restoring full cordless operation for otoscopes, ophthalmoscopes, retinoscopes and related 3.5 V instruments. The 72300 battery is a cylindrical, orange-lettered power-cell assembly engineered to meet Welch Allyn’s requirements for capacity, runtime and reliability in clinical environments.

Bnefits

  • Direct replacement battery for Welch Allyn 71000-A and 71000-C 3.5 V rechargeable power handles, ensuring correct fit and performance.
  • Nickel–cadmium chemistry designed for repeated charge–discharge cycles in demanding clinical use.
  • Provides reliable power for 3.5 V Welch Allyn otoscopes, ophthalmoscopes, retinoscopes and other compatible instruments.
  • Helps restore original runtime and brightness compared with depleted or ageing batteries.
  • Re-usable, rechargeable design reduces the need for disposable primary cells and supports lower long-term running costs.
  • OEM-style construction maintains handle balance and ergonomics that clinicians are accustomed to.
  • Widely recognised part number (72300) makes sourcing and inventory management straightforward.

Indications

  • Intended as a replacement rechargeable battery for Welch Allyn 3.5 V rechargeable power handles model 71000-A and 71000-C.
  • Used to power 3.5 V Welch Allyn diagnostic instruments such as otoscopes, ophthalmoscopes, retinoscopes and similar devices designed for 3.5 V rechargeable handles.
  • Suitable for clinical environments including GP surgeries, ENT practices, ophthalmology clinics, hospitals and urgent care centres where Welch Allyn 3.5 V handles are in routine use.

Composition

  • Battery chemistry: Nickel–cadmium (NiCd) rechargeable cell assembly.
  • Active materials: Nickel oxyhydroxide and cadmium-based electrodes with alkaline electrolyte.
  • Cylindrical cell pack enclosed in a robust outer sleeve with identifying orange/white labelling (varies by market).
  • Metal terminals integrated into the pack ends to interface with the internal contacts of Welch Allyn 3.5 V handles.

Formulation

  • Battery type: Rechargeable NiCd battery for 3.5 V diagnostic power handles.
  • Nominal voltage: 3.5 V.
  • Typical capacity: approximately 800 mAh (varies slightly by batch and supplier).
  • Form factor: Cylindrical pack sized to fit Welch Allyn 71000-A / 71000-C handle bores.
  • Compatibility: 71000-A and 71000-C wall/direct plug-in rechargeable handles, and other compatible Welch Allyn 3.5 V rechargeable power handles as specified in device documentation.
  • Charging: Intended for use with Welch Allyn charging systems designed for 3.5 V NiCd rechargeable handles (e.g. wall transformers / desk chargers compatible with 71000-A / 71000-C).

Packaging

  • Supplied as a single rechargeable battery (one 72300 pack per unit).
  • Individually packaged in protective manufacturer or distributor packaging to prevent mechanical damage in transit.
  • Labelling includes Welch Allyn branding, part number 72300, nominal voltage (3.5 V), chemistry (NiCd) and basic identification as a rechargeable handle battery.
  • Distributed by Medisave UK within their diagnostics/spares and accessories product ranges.

Usage

  • Only trained personnel or clinicians familiar with Welch Allyn 3.5 V handles should replace the battery.
  • Ensure the handle is disconnected from mains power and any charging source before battery replacement.
  • Unscrew and open the handle according to the Welch Allyn instructions for use to access the internal battery compartment.
  • Remove the existing 3.5 V rechargeable battery, noting its orientation inside the handle.
  • Insert the new 72300 battery into the handle in the correct orientation, ensuring good contact with internal terminals.
  • Reassemble and securely tighten the handle components.
  • Place the handle on the appropriate Welch Allyn charger (wall transformer or desk charger compatible with 3.5 V handles) and allow the battery to fully charge before first use.
  • After charging, test the handle with the connected instrument (otoscope, ophthalmoscope, etc.) to confirm normal illumination and operation.
  • Follow Welch Allyn’s guidance on charging cycles to maximise battery life (e.g. avoid prolonged continuous overcharging beyond manufacturer recommendations).
  • Do not attempt to open or modify the battery pack; it is not user-serviceable beyond normal installation and removal.

Contraindications

  • Do not use this battery in devices that are not specified as compatible with Welch Allyn 3.5 V NiCd handle batteries (e.g. devices requiring different voltage, chemistry or size).
  • Not suitable for use in non-rechargeable (primary cell) handles or in handles designed for lithium-ion battery packs.
  • Do not install or use the battery if the casing is damaged, cracked, swollen or shows signs of leakage.
  • Avoid use in environments where exposure to excessive heat, open flame or strong oxidising chemicals is possible.
  • Use only with approved Welch Allyn chargers intended for 3.5 V NiCd rechargeable handles; using incompatible chargers can cause overheating or reduced battery life.

Adverse Effects

  • If the battery is damaged and electrolyte leaks, contact with skin or eyes may cause irritation or chemical burns; flush with plenty of water and seek medical attention.
  • Incorrect charging or short-circuiting can cause the battery to overheat, potentially leading to burns, fire or venting of gases.
  • Improper disposal of NiCd batteries can contribute to environmental contamination due to cadmium content.
  • A failing or inadequately charged battery may result in dim illumination or sudden power loss during examination, which could interfere with clinical assessments; routine checks of charge status are recommended.

Storage Conditions

  • Store unused batteries in their original packaging in a cool, dry, well-ventilated environment.
  • Avoid storage in high-temperature locations, direct sunlight or near heat sources, as excessive heat can shorten battery life.
  • Keep away from moisture, corrosive vapours and conductive materials that could bridge the terminals.
  • For long-term storage, follow general NiCd recommendations: moderate temperature, partial charge, and periodic top-up charging where practical, in line with institutional policy.
  • Do not store batteries loose where they may contact metal objects and short-circuit.
  • Keep out of reach of children and unauthorised personnel.

Duration

Onset

Browse more Diagnostic Equipment & Accessories

ELI 150c Resting Electrocardiograph

ELI 150c Resting Electrocardiograph

Medisave

ELI 150c Resting Electrocardiograph

Medical and Aesthetic Equipment
  • £4,822.79
  • £4,078.79
  • 5 more

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medisave

MicroTymp3 Tips - 4 Extra Small (7 mm) for Welch Allyn otoscopes

Medical and Aesthetic Equipment
  • £25.99
  • £28.99
  • 7 more

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medisave

ELI150c Resting Electrocardiograph with Wireless Patient Cable Module (WAM), Ethernet LAN, XML & PDF, UK Plug

Medical and Aesthetic Equipment
  • £3,091.19
  • £2,762.39
  • 3 more

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry \u2013 Plug 4

Medisave

Welch Allyn Connex Spot Monitor with SureBP Non-Invasive Blood Pressure, Covidien SpO2 and Braun ThermoScan PRO 6000 Thermometry – Plug 4

Medical and Aesthetic Equipment
  • £736.79
  • £571.19
  • 3 more

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medisave

Welch Allyn Comfort Sealing Eartips (Large, one pair)

Medical and Aesthetic Equipment
  • £5.49
  • £35.99
  • 2 more

Miller 00 Fiber Optic Laryngoscope Blade

Miller 00 Fiber Optic Laryngoscope Blade

Medisave

Miller 00 Fiber Optic Laryngoscope Blade

Medical and Aesthetic Equipment
  • £206.39
  • £206.39
  • 2 more

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

ProBP\u2122 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medisave

ProBP™ 2000 Digital Blood Pressure Device with Power Supply - CLEARANCE

Medical and Aesthetic Equipment
  • £87.59
  • £257.99
  • 2 more

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medisave

GS777 Integrated Wall System, PanOptic, MacroView for CSM UK

Medical and Aesthetic Equipment
  • £2,279.99
  • £2,243.99
  • 0 more

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medisave

Welch Allyn SureBP Double-Tube Blood Pressure Hose, 10 ft (3.0 m)

Medical and Aesthetic Equipment
  • £80.39
  • £64.79
  • 1 more

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medisave

ELI 230 Resting Electrocardiograph with Wireless Patient Cable Module (WAM), UK Plug

Medical and Aesthetic Equipment
  • £1,689.59
  • £1,919.99
  • 0 more

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medisave

ProBP 2400 Blood Pressure Cuff, Large Adult Long (32 - 52cm)

Medical and Aesthetic Equipment
  • £46.79
  • £56.39
  • 1 more

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medisave

ECG Thermal Z-Fold to Use With ELI150/150C - 1 Pack of 200 Sheets

Medical and Aesthetic Equipment
  • £32.39
  • £14.39
  • 1 more