Z Fold Paper for Welch Allyn CP100, CP150 and CP200 ECG Machines x 200
Welch Allyn
Medical consumable
ECG recording chart paper (Z-fold thermal)
Certifications
Welch Allyn Branded ECG recording chart paper produced to match the specifications and performance requirements of CP100, CP150 and CP200 electrocardiographs
Distributed by established medical suppliers who operate quality management systems (for example, ISO 9001 and ISO 14001 in the case of Medisave UK)
Welch Allyn Branded ECG recording chart paper produced to match the specifications and performance requirements of CP100, CP150 and CP200 electrocardiographs
Distributed by established medical suppliers who operate quality management systems (for example, ISO 9001 and ISO 14001 in the case of Medisave UK)
ECG recording chart paper (Z-fold thermal)
Description
Z Fold Paper for Welch Allyn CP100, CP150 and CP200 ECG Machines is original Welch Allyn Z-fold thermal recording chart paper with a red grid, designed specifically for use in CP100, CP150 and CP200 electrocardiographs. Each pack contains 200 Z-fold sheets of 8.25 x 11 inch (approximately 210 x 280 mm) thermal paper, providing clear, accurate ECG tracings when used with the compatible devices. The paper is supplied as a single pack of 200 sheets for easy loading and continuous ECG recording.
Bnefits
Original Welch Allyn Z-fold thermal chart paper designed specifically for CP100, CP150 and CP200 ECG machines
Red grid pattern supports accurate measurement and interpretation of ECG waveforms
Z-fold format enables continuous, jam-resistant ECG printouts without the need for cutting individual sheets
Optimised thermal coating provides clear, legible traces when used with compatible printers
Pack of 200 sheets helps ensure adequate stock for routine ECG recording
Consistent dimensions and fold pattern ensure correct alignment in the printer mechanism
Supplied by established medical distributors, helping to assure authenticity and quality
Indications
Recording and printing of electrocardiogram (ECG) traces from Welch Allyn CP100, CP150 and CP200 electrocardiographs
Use in clinical settings such as hospitals, GP practices and diagnostic centres that operate Welch Allyn CP-series ECG machines
For documenting resting ECG examinations and archiving ECG results in paper form
Composition
Thermal-sensitive ECG recording paper with red grid pattern
Z-folded sheets for continuous feed operation
Approximate basis weight around 80 g/m² (typical of premium ECG thermal paper used for compatibility listings)
Sheet dimensions approximately 8.25 x 11 inches (210 x 280 mm)
Formulation
Chart type: Z-fold ECG recording paper
Grid colour: Red
Dimensions: approximately 8.25 x 11 inches (210 x 280 mm)
Paper type: Thermal, multi-channel ECG recording paper
Number of sheets per pack: 200
Compatibility: Welch Allyn CP100, CP150 and CP200 electrocardiographs
Packaging
Supplied as one pack containing 200 Z-fold sheets
Pack enclosed in a protective carton or wrapper to keep paper clean and dry in storage
Outer cases (from some distributors) may contain multiple 200-sheet packs, but this specific listing is for a single 200-sheet pack
Packaging is labelled with product identification, brand (Welch Allyn) and compatibility information for CP100, CP150 and CP200 ECG machines
Usage
Verify that the paper type and size are correct for the Welch Allyn CP100, CP150 or CP200 ECG machine before loading.
Open the ECG paper compartment of the ECG machine following the manufacturer’s instructions for the specific model.
Place the Z-fold stack in the paper tray, ensuring the first sheet feeds from the correct side so that the thermal-sensitive surface faces the print head.
Align the edges of the Z-fold stack so that the paper feeds straight without twisting or bunching.
Close the paper compartment and, if available, perform a test print or ECG to confirm that traces are printing clearly and correctly aligned on the grid.
Replace the paper with a new pack when the current stack is nearly exhausted to avoid running out during an ECG recording.
Dispose of used ECG printouts according to local policies on medical records retention and confidential waste handling.
Contraindications
Not intended for use with ECG machines other than Welch Allyn CP100, CP150 and CP200 or other devices specifically confirmed as compatible.
Do not use if the paper has been exposed to moisture, excessive heat or visible contamination that could impair print quality or damage the ECG printer.
Do not use damaged or torn paper stacks that could jam or misfeed within the ECG printer.
Adverse Effects
No direct patient adverse effects are expected from the paper itself when used correctly.
Poor-quality or incompatible paper may produce faint, incomplete or distorted ECG traces, which could impact readability and clinical interpretation if not detected.
Paper dust or debris from damaged packs may contribute to increased maintenance requirements or occasional printer jams.
Storage Conditions
Store in a cool, dry place away from direct sunlight and sources of heat.
Keep packs in their original packaging until use to protect against dust, moisture and physical damage.
Avoid storing near strong chemicals or solvents that could affect the thermal coating.
Observe the manufacturer’s recommended storage temperature and humidity ranges where provided, and use the paper before the indicated expiry date for best print quality.
Duration
Not applicable; each sheet is used once for the duration of an ECG recording and then retained or disposed of according to clinical record-keeping policies.
Onset
Not applicable; this is a non-pharmacological recording medium that provides immediate visual output when the ECG machine prints.