Aurelia Bold MAX Powder Free Black Nitrile Gloves Box of 50
Aurelia
Nitrile Gloves
Black heavy-duty diamond-textured nitrile examination gloves
Certifications
PPE Regulation (EU) 2016/425, Category III.
Medical Device Regulation (EU) 2017/745, and legacy Directive 93/42/EEC (medical examination glove).
BS EN 455 Parts 1–4: Medical gloves for single use (freedom from holes, physical properties, biological evaluation, shelf life).
BS EN ISO 374 1:2016 (and amendments) Type B JKPT – protective gloves against dangerous chemicals.
PPE Regulation (EU) 2016/425, Category III.
Medical Device Regulation (EU) 2017/745, and legacy Directive 93/42/EEC (medical examination glove).
BS EN 455 Parts 1–4: Medical gloves for single use (freedom from holes, physical properties, biological evaluation, shelf life).
BS EN ISO 374 1:2016 (and amendments) Type B JKPT – protective gloves against dangerous chemicals.
BS EN ISO 374 5:2016 – protective gloves against microorganisms including viruses.
Description
Aurelia Bold MAX Powder Free Black Nitrile Gloves are heavy-duty, premium black nitrile examination gloves engineered for high tensile strength and superior chemical and puncture resistance. With a 6.0 mil (approx. 0.15 mm) nominal thickness and a full diamond-textured surface, they deliver exceptional grip and control, especially in wet or oily conditions. These non-sterile, ambidextrous, latex-free gloves are supplied in boxes of 50 Large-size gloves, are powder free, and are tested as both medical examination gloves and Category III PPE against chemicals and microorganisms.
Bnefits
Heavy-duty 7.5 g nitrile construction (approx. 6 mil) provides excellent durability, puncture resistance and tensile strength.
Full diamond-textured surface offers unrivalled grip and control, particularly in wet, oily or greasy environments.
Premium nitrile formulation delivers superior chemical resistance compared to latex or vinyl examination gloves within tested ranges.
Powder-free and latex-free design reduces the risk of powder-related contamination and latex-associated allergies.
Black colour helps mask stains such as oil, grease, ink, dyes or blood, and offers high contrast for contamination visibility.
Ambidextrous design and beaded cuff make donning and removal easier while improving cuff strength.
Medical grade with AQL 1.5 and tested to EN 455 1–4 for use as single-use examination gloves.
Certified to EN ISO 374-1, 2, 4, 5 for protection against dangerous chemicals and microorganisms, including viruses (Type B JKPT).
Food-contact compliant (BS EN 1186), suitable for food handling applications when required.
Indications
Use as non-sterile examination gloves in medical, dental and healthcare settings where heavy-duty protection is desirable.
Aesthetic medicine, dermatology, tattooing, piercing and beauty procedures requiring robust, dark-coloured gloves with excellent grip.
Automotive, mechanical, engineering and maintenance tasks with exposure to oils, grease, fuels and dirt.
Industrial, janitorial, cleaning and facilities management tasks requiring strong disposable chemical-resistant gloves within tested EN ISO 374 limits.
6 mil heavy-duty nitrile formulation for extra strength and durability.
Diamond-textured external surface over fingers, palm and hand.
Ambidextrous design to fit either hand.
Beaded cuff to reduce tearing and prevent roll-down.
AQL 1.5 for pinhole defects, medical grade.
Available sizes: Medium, Large, Extra Large, XXL; this SKU refers to Large.
Packaging
Box containing 50 single-use black nitrile examination gloves (by count).
Inner box dimensions approximately 240 x 130 x 70 mm.
Outer shipping case: 10 inner boxes per case (10 x 50 gloves = 500 gloves), approx. 360 x 270 x 255 mm.
Packaging clearly marked with size (L), lot number, manufacture date, expiry date, and regulatory/standard markings.
Barcodes (EAN-13) for Large: inner box 955-500211-3070; outer case 1955-500211-3077 (per manufacturer product sheet).
Usage
Check the box and inner packaging before use; do not use if packaging is damaged or if the product is past its expiry date.
Ensure hands are clean and dry; remove jewellery or trim nails that could puncture or tear the glove.
Select the correct size (Large) to ensure a snug, comfortable fit without excessive stretching.
To don, remove a glove from the dispensing box by the cuff, insert the fingers and thumb, then pull the beaded cuff over the wrist, smoothing out any folds.
Repeat for the other hand, maintaining aseptic technique where clinically indicated.
During use, avoid contact with chemicals outside the glove’s validated EN ISO 374 resistance list; follow local COSHH/risk assessments.
Change gloves between patients, between different tasks on the same patient, or immediately if the glove is torn, punctured, heavily soiled or after contact with aggressive chemicals.
To remove, grasp the outside of one glove near the wrist and peel it off inside out, holding it in the gloved hand; slide an ungloved finger under the cuff of the remaining glove and peel it off over the first glove without touching the contaminated exterior.
Dispose of used gloves safely according to local clinical, hazardous or general waste requirements; do not reuse single-use gloves.
Wash or sanitise hands after glove removal as per hand-hygiene protocols.
Contraindications
Known or suspected hypersensitivity or allergy to nitrile or any of the glove’s compounding ingredients or colourants.
Use in procedures that require sterile surgical gloves; Bold MAX gloves are non-sterile examination gloves.
Use with highly aggressive chemicals, solvents or cytotoxic agents not covered by the glove’s EN ISO 374 chemical resistance data or manufacturer guidance.
Use in high-heat, open flame or molten-material environments; nitrile examination gloves are not flame- or heat-resistant PPE.
Do not use if gloves show signs of degradation such as brittleness, stickiness, tears, holes, discolouration or if the packaging is compromised.
Adverse Effects
Possible skin irritation, contact dermatitis or allergic reactions in sensitised individuals exposed to nitrile compounds, accelerators or dyes.
Skin maceration or excessive sweating if gloves are worn continuously for extended periods without breaks.
Reduced tactile sensitivity and fine motor control if incorrect size is used or more than one glove is worn per hand.
Inadequate protection and increased risk of exposure if gloves are reused, worn beyond their intended duration or used with incompatible chemicals.
Potential tearing or puncture if used with sharp instruments, long nails or jewellery, compromising barrier integrity.
Storage Conditions
Store in a cool, dry place away from direct sunlight, UV sources and excessive heat.
Recommended storage temperature typically between 5°C and 25°C; avoid freezing temperatures and high heat.
Keep away from ozone generators and chemicals, oils or solvents that may degrade nitrile.
Store in the original packaging until use to protect from dust, moisture and contamination.
Do not use after the expiry date printed on the packaging, in line with EN 455-4 shelf-life requirements.
Duration
Single-use disposable glove intended for one task or patient contact episode only; must be changed between tasks, between patients, or whenever damaged or visibly contaminated.
Onset
Provides immediate barrier protection and grip enhancement upon correct donning.